HLHyeongtae Lim

Hyeongtae Lim

*This is an algorithmically generated author record based on publicly available information.

Hyeongtae Lim has a total of 32 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Synergistic Integration of Laser Oxidation and Long Short-Term Memory for Advanced Odor Classification in Next-Generation Artificial Olfactory Systems

    by Hyeokjin Kwon, Jiho Park, Hyun Woo Jang, Hyeongtae Lim, Sohee Kim, Samhwan Kim, Jae Eun Jang, Hyuk-Jun Kwon, Ji-Woong Choi

    Emulating and enhancing human olfactory capabilities, artificial olfactory technology provides adept detection of subtle odors, gases, and various chemical substances. Metal oxide semiconductors (MOSs) are ideal materials for next-generation artificial olfactory devices due to their outstanding gas sensing performance, characterized high sensitivity, high response speed, and robust stability, as well as their compatibility with microfabrication. For broader applications, developing a comprehensive database of diverse odorants is crucial, which necessitates expanding the types of MOS channels in artificial olfactory devices. This paper reports a laser-induced oxidation-based artificial olfactory device using a 7 × 3 sensor array composed of three metal oxides (SnO2-x, ZnOx, and WO3-x). By analyzing the response pattern of various odorants using a deep neural network, the device achieved 95.2% accuracy in classifying eight single odor molecules. Additionally, it successfully deconvoluted the types and concentrations of two odor mixtures and classified ten types of wine with accuracies of 91.3% and 92.5%, respectively. Furthermore, this study identified the proper number and arrangement of sensors for next-generation e-nose development. Our innovative artificial olfactory system can be integrated into various fields, such as the aromatic industry and virtual reality, making it a beneficial technology for future artificial olfaction applications.


  • Open Access

    Intelligent Olfactory System Utilizing In Situ Ceria Nanoparticle-Integrated Laser-Induced Graphene

    by Hyeongtae Lim, Hyeokjin Kwon, Jae Eun Jang, Hyuk-Jun Kwon

    The digitization of human senses has driven innovation across various technologies and transformed our daily lives, yet the digitization of olfaction remains a challenging frontier. Artificial olfactory systems, or electronic noses (e-noses), offer great potential for environmental monitoring, food safety, healthcare, and the fragrance industry. However, integrating sensor arrays that mimic olfactory receptors remains difficult, typically requiring complex, repetitive, and costly fabrication processes. In this research, we report the development of a porous laser-induced graphene (LIG) sensor array with in situ-doped cerium oxide nanoparticles for the classification of odorant molecules. By adjusting the laser irradiation parameters, we achieve a high degree of physical and chemical diversity in both LIG and CeOx. Consequently, a sensor array exhibiting diverse response patterns to different odorant molecules can be fabricated through one-step laser irradiation of a polymer precursor. Using t-distributed stochastic neighbor embedding (t-SNE) and support vector machine (SVM)-based machine learning, we accurately predict the type and concentration of nine odorant molecules used in perfumes and cosmetics, achieving a high accuracy exceeding 95%. This study provides a rapid and straightforward solution for creating functional olfactory receptor-mimicking arrays, advancing the development of artificial olfaction systems.


  • Open Access

    Hexagonal metal complex based mechanically robust transparent ultrathin gold µECoG for electro-optical neural interfaces

    by Duhee Kim, Murali Bissannagari, Boil Kim, Nari Hong, Jaeu Park, Hyeongtae Lim, Junhee Lee, Jungha Lee, Yoon Kyoung Kim, Youngjae Cho, et al.

    Transparent electro-optical neural interfacing technologies offer simultaneous high-spatial-resolution microscopic imaging, and high-temporal-resolution electrical recording and stimulation. However, fabricating transparent, flexible, and mechanically robust neural electrodes with high electrochemical performance remains challenging. In this study, we fabricated transparent (72.7% at 570 nm), mechanically robust (0.05% resistance change after 50k bending cycles) ultrathin Au microelectrodes for micro-electrocorticography (µECoG) using a hexadentate metal-polymer ligand bonding with an EDTA/PSS seed layer. These transparent µECoG arrays, fabricated with biocompatible gold, exhibit excellent electrochemical properties (0.73 Ω·cm2) for neural recording and stimulation with long-term stability. We recorded brain surface waves in vivo, maintaining a low baseline noise and a high signal-to-noise ratio during acute and two-week recordings. In addition, we successfully performed optogenetic modulation without light-induced artifacts at 7.32 mW/mm2 laser power density. This approach shows great potential for scalable, implantable neural electrodes and wearable optoelectronic devices in digital healthcare systems.


  • Open Access

    Flex-to-Stretch Hybrid Electronics—Bonding-Free Robust Interface for Wearable Wireless Physiological Monitoring

    by Srinivas Gandla, Sunju Kang, Junho Kim, Yunjeong Yu, Jaeseong Kim, Hyeongtae Lim, Hyuk-Jun Kwon, Sung-Min Park, Sunkook Kim

    Hybrid electronics require a robust mechanical interface between externally fabricated stretchable sensors and flexible printed circuit boards (FPCBs) to obtain stable electrophysiological information. The most advanced technique for the integration of FPCBs with stretchable sensors is anisotropic conductive film bonding. Fabricating high-performance sensors requires microfabrication techniques, such as photolithography and etching, which are cumbersome and expensive. Therefore, a sensor fabrication process that supports FPCB manufacturing with lower complexity and cost is required. Herein, we propose a bonding-free approach for fabricating FPCBs and stretchable sensors on a single substrate. This approach utilizes in- and out-of-plane mechanical gradients to obtain a robust and durable mechanical interface for a smooth transition of the internal mechanical stress compliance, as confirmed by experiments and simulations. The gradient mesh patterns, without ACF bonding, can withstand tensile strains of over 30% before experiencing electrical breakdown. Additionally, Kirigami-inspired mesh patterns can extend stretchability by over 100%. The electrical performance of temperature sensors (linear response to temperature changes) and electrocardiography (ECG) sensors (clear visibility of PQRST peaks) remains stable under various physical activities. User-accessible, facile laser ablation and cutting techniques compatible with the FPCB manufacturing process were employed to fabricate stretchable sensors. This approach enables the development of FPCB-compatible on-skin stretchable sensors with robust mechanical properties.


  • Top Cited Papers
    Open Access

    Semiconducting MOFs on ultraviolet laser-induced graphene with a hierarchical pore architecture for NO2 monitoring

    by Hyeongtae Lim, Hyeokjin Kwon, Hongki Kang, Jae Eun Jang, Hyuk-Jun Kwon

    Due to rapid urbanization worldwide, monitoring the concentration of nitrogen dioxide (NO2), which causes cardiovascular and respiratory diseases, has attracted considerable attention. Developing real-time sensors to detect parts-per-billion (ppb)-level NO2 remains challenging due to limited sensitivity, response, and recovery characteristics. Herein, we report a hybrid structure of Cu3HHTP2, 2D semiconducting metal-organic frameworks (MOFs), and laser-induced graphene (LIG) for high-performance NO2 sensing. The unique hierarchical pore architecture of LIG@Cu3HHTP2 promotes mass transport of gas molecules and takes full advantage of the large surface area and porosity of MOFs, enabling highly rapid and sensitive responses to NO2. Consequently, LIG@Cu3HHTP2 shows one of the fastest responses and lowest limit of detection at room temperature compared with state-of-the-art NO2 sensors. Additionally, by employing LIG as a growth platform, flexibility and patterning strategies are achieved, which are the main challenges for MOF-based electronic devices. These results provide key insight into applying MOFtronics as high-performance healthcare devices.