Insu Paek
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Insu Paek has a total of 2 co-authors. Here are the top co-authors by number of shared publications:
James E. Braun
Ray W. Herrick Laboratories, School of Mechanical Engineering, Purdue University, 140 South Intramural Drive, West Lafayette, Indiana 47907-2031
1 shared publication- Luc Mongeau
Department of Mechanical Engineering, McGill University, Montreal, QC, Canada
1 shared publication
Latest Publications
- 1 January 2005
- Published by Acoustical Society of America (ASA) in The Journal of the Acoustical Society of America
- Vol. 117 (1) , 185-193
A method for estimating the parameters of electrodynamic drivers in thermoacoustic coolers
The electroacoustic efficiency of high-power actuators used in thermoacoustic coolers may be estimated using a linear model involving a combination of six parameters. A method to identify these equivalent driver parameters from measured total electrical impedance and velocity-voltage transfer function data was developed. A commercially available, moving-magnet driver coupled to a functional thermoacoustic cooler was used to demonstrate the procedure experimentally. The method, based on linear electrical circuit theory, allowed for the possible frequency and amplitude dependence of the driver parameters to be estimated. The results demonstrated that driver parameters measured in vacuo using this method can be used to predict the driver efficiency and performance for operating conditions which may be encountered under load.
- 1 January 2005
- Published by Acoustical Society of America (ASA) in The Journal of the Acoustical Society of America
- Vol. 117 (1) , 185-193
A method for estimating the parameters of electrodynamic drivers in thermoacoustic coolers
The electroacoustic efficiency of high-power actuators used in thermoacoustic coolers may be estimated using a linear model involving a combination of six parameters. A method to identify these equivalent driver parameters from measured total electrical impedance and velocity-voltage transfer function data was developed. A commercially available, moving-magnet driver coupled to a functional thermoacoustic cooler was used to demonstrate the procedure experimentally. The method, based on linear electrical circuit theory, allowed for the possible frequency and amplitude dependence of the driver parameters to be estimated. The results demonstrated that driver parameters measured in vacuo using this method can be used to predict the driver efficiency and performance for operating conditions which may be encountered under load.