Roosha Parikh
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Roosha Parikh has a total of 132 co-authors. Here are the top co-authors by number of shared publications:
- Omar K. Khalique
Division of Cardiovascular Imaging, St. Francis Hospital and Catholic Health, Roslyn, NY 11576, USA
8 shared publications - Ziad A. Ali
St. Francis Hospital and Heart Center
7 shared publications - Jaffar Mohammad Khan
Cardiovascular Branch, Division of Intramural Research, National Heart, Lung, and Blood Institute, National Institutes of Health, Bethesda, MD (T.R., J.M.K., C.G.B., A.M.S., R.J.L.).
6 shared publications Doosup Shin
Division of Cardiovascular Imaging, St. Francis Hospital and Heart Center, Roslyn
4 shared publications- Jonathan Weber
Department of Cardiology, St Francis Hospital and Heart Center, Roslyn, New York, USA
4 shared publications - Doosup Shin
St. Francis Hospital and Heart Center
3 shared publications
Latest Publications
- 1 October 2026
- Published by Wolters Kluwer Health in Circulation: Cardiovascular Imaging
- Vol. 19 (10) , e019341
Low Contrast Photon-Counting Detector CT Using Spectral Information to Enhance Structural Heart Intervention Planning
- 1 October 2026
- Published by Wolters Kluwer Health in Circulation: Cardiovascular Imaging
- Vol. 19 (10) , e019341
Low Contrast Photon-Counting Detector CT Using Spectral Information to Enhance Structural Heart Intervention Planning
- 26 August 2026
- Published by Wolters Kluwer Health in Current Opinion in Cardiology
- Vol. 41 (6) , 575-583
Diagnostic performance and clinical impact of photon-counting detector computed tomography in coronary artery disease
Purpose of review: Photon-counting detector computed tomography (PCD-CT) is an emerging technology that addresses key limitations of conventional coronary CT angiography, including calcium blooming, stent-related artifacts, and limited spatial resolution. This review summarizes recent evidence regarding the diagnostic performance and clinical impact of PCD-CT in the evaluation of coronary artery disease (CAD) and discusses its potential role in contemporary cardiovascular imaging. Recent findings: Recent studies demonstrate that PCD-CT provides superior spatial resolution, improved contrast-to-noise ratio, and reduced blooming artifacts compared with conventional energy-integrating detector CT. Clinical investigations have shown improved diagnostic accuracy for detecting obstructive CAD, particularly in patients with heavy coronary calcification, older patients and coronary stents. Large observational studies report higher specificity, improved positive predictive value, fewer indeterminate examinations, reduced invasive coronary angiography referrals, and greater revascularization yield. Emerging applications include advanced plaque characterization, extracellular volume quantification, and ultra-low-dose radiation and contrast imaging. Summary: Current evidence suggests that PCD-CT represents a transformative advancement in noninvasive coronary imaging. Beyond improving diagnostic accuracy, PCD-CT may enhance clinical decision-making, reduce unnecessary downstream testing, and expand the role of CT in comprehensive cardiovascular assessment. Future multicenter outcome studies and standardized imaging protocols will be essential to establish its long-term clinical and economic value.
- 26 August 2026
- Published by Wolters Kluwer Health in Current Opinion in Cardiology
- Vol. 41 (6) , 575-583
Diagnostic performance and clinical impact of photon-counting detector computed tomography in coronary artery disease
Purpose of review: Photon-counting detector computed tomography (PCD-CT) is an emerging technology that addresses key limitations of conventional coronary CT angiography, including calcium blooming, stent-related artifacts, and limited spatial resolution. This review summarizes recent evidence regarding the diagnostic performance and clinical impact of PCD-CT in the evaluation of coronary artery disease (CAD) and discusses its potential role in contemporary cardiovascular imaging. Recent findings: Recent studies demonstrate that PCD-CT provides superior spatial resolution, improved contrast-to-noise ratio, and reduced blooming artifacts compared with conventional energy-integrating detector CT. Clinical investigations have shown improved diagnostic accuracy for detecting obstructive CAD, particularly in patients with heavy coronary calcification, older patients and coronary stents. Large observational studies report higher specificity, improved positive predictive value, fewer indeterminate examinations, reduced invasive coronary angiography referrals, and greater revascularization yield. Emerging applications include advanced plaque characterization, extracellular volume quantification, and ultra-low-dose radiation and contrast imaging. Summary: Current evidence suggests that PCD-CT represents a transformative advancement in noninvasive coronary imaging. Beyond improving diagnostic accuracy, PCD-CT may enhance clinical decision-making, reduce unnecessary downstream testing, and expand the role of CT in comprehensive cardiovascular assessment. Future multicenter outcome studies and standardized imaging protocols will be essential to establish its long-term clinical and economic value.
- Open Access
- 22 May 2026
- Published by Elsevier in JACC: Case Reports
- Vol. 31 (26) , 108459
Positron Emission Tomography/Computed Tomography Scanner for Pre-Transcatheter Aortic Valve Replacement Assessment
- 22 May 2026
- Published by Elsevier in JACC: Case Reports
- Vol. 31 (26) , 108459
Open AccessPositron Emission Tomography/Computed Tomography Scanner for Pre-Transcatheter Aortic Valve Replacement Assessment
- Open Access
- 12 March 2026
- Published by Elsevier in Journal of the Society for Cardiovascular Angiography & Interventions
- Vol. 5 (5)
Effect of Intravascular Lithotripsy on Mitral Annular Calcification: A Cadaveric Study
- 12 March 2026
- Published by Elsevier in Journal of the Society for Cardiovascular Angiography & Interventions
- Vol. 5 (5)
Open AccessEffect of Intravascular Lithotripsy on Mitral Annular Calcification: A Cadaveric Study
- Open Access
- 11 December 2025
- Published by MDPI AG in Tomography
- Vol. 11 (12) , 139
Aortic Valve Calcium Scoring Using True and Virtual Non-Contrast Reconstructions on Photon-Counting CT with Differing Slice Increments: Impact on Calcium Severity Classifications
Background/Objectives: Aortic valve calcification is commonly evaluated using 3.0 mm true non-contrast (TNC) computed tomography (CT) images. This study evaluates the reproducibility of virtual non-contrast (VNC) reconstructions at different slice intervals using photon-counting detector CT (PCD-CT). Methods: In this retrospective study, we included 279 consecutive patients, who underwent PCD-CT for evaluation of native aortic valve between February 2023 and December 2023 with both TNC and VNC images at 3.0 and 1.5 mm slice intervals. Aortic valve calcium score (AVCS) and aortic valve calcium volume (AVCV) were compared between the two methods using paired t-tests. Agreement for continuous variables was assessed using inter-class coefficients (ICCs). Cohen’s Kappa (κ) was calculated to evaluate the agreement between different modalities in diagnosing severe AV calcification. Results: Compared to the standard, TNC images at 1.5 mm intervals showed higher AVCS (mean difference: −290 ± 418, p < 0.001), with high reproducibility between techniques (CS: ICC 0.969, [IQR 0.962, 0.975]). Compared with reference, VNC showed no significant differences in AVCS at either slice intervals, with excellent reproducibility (3.0 mm, ICC 0.970 [0.963, 0.976]; 1.5 mm, ICC 0.971 [0.964, 0.977]). Compared to TNC 3.0 mm, strong concordance was observed using other reconstruction techniques in assessing severe AV calcification (κ = 0.81 [95% CI: 0.74–0.88], 0.83 [95% CI: 0.76–0.90], and 0.83 [95% CI: 0.76–0.90] for TNC at 1.5 mm, VNC at 3.0 mm, and 1.5 mm, respectively), with low misclassification rates. Conclusions: Our study highlights high reproducibility in the evaluation of AVCS by VNC reconstruction at 3.0 and 1.5 mm intervals compared with reference offering a reliable alternative with an excellent diagnostic accuracy.
- 11 December 2025
- Published by MDPI AG in Tomography
- Vol. 11 (12) , 139
Open AccessAortic Valve Calcium Scoring Using True and Virtual Non-Contrast Reconstructions on Photon-Counting CT with Differing Slice Increments: Impact on Calcium Severity Classifications
Background/Objectives: Aortic valve calcification is commonly evaluated using 3.0 mm true non-contrast (TNC) computed tomography (CT) images. This study evaluates the reproducibility of virtual non-contrast (VNC) reconstructions at different slice intervals using photon-counting detector CT (PCD-CT). Methods: In this retrospective study, we included 279 consecutive patients, who underwent PCD-CT for evaluation of native aortic valve between February 2023 and December 2023 with both TNC and VNC images at 3.0 and 1.5 mm slice intervals. Aortic valve calcium score (AVCS) and aortic valve calcium volume (AVCV) were compared between the two methods using paired t-tests. Agreement for continuous variables was assessed using inter-class coefficients (ICCs). Cohen’s Kappa (κ) was calculated to evaluate the agreement between different modalities in diagnosing severe AV calcification. Results: Compared to the standard, TNC images at 1.5 mm intervals showed higher AVCS (mean difference: −290 ± 418, p < 0.001), with high reproducibility between techniques (CS: ICC 0.969, [IQR 0.962, 0.975]). Compared with reference, VNC showed no significant differences in AVCS at either slice intervals, with excellent reproducibility (3.0 mm, ICC 0.970 [0.963, 0.976]; 1.5 mm, ICC 0.971 [0.964, 0.977]). Compared to TNC 3.0 mm, strong concordance was observed using other reconstruction techniques in assessing severe AV calcification (κ = 0.81 [95% CI: 0.74–0.88], 0.83 [95% CI: 0.76–0.90], and 0.83 [95% CI: 0.76–0.90] for TNC at 1.5 mm, VNC at 3.0 mm, and 1.5 mm, respectively), with low misclassification rates. Conclusions: Our study highlights high reproducibility in the evaluation of AVCS by VNC reconstruction at 3.0 and 1.5 mm intervals compared with reference offering a reliable alternative with an excellent diagnostic accuracy.
- Open Access
- 13 November 2025
- Published by Elsevier in JACC: Advances
- Vol. 4 (12) , 102284
Noninvasive Cardiac Imaging in Older Adults
- 13 November 2025
- Published by Elsevier in JACC: Advances
- Vol. 4 (12) , 102284
Open AccessNoninvasive Cardiac Imaging in Older Adults
- 3 November 2025
- Published by Elsevier in JACC: Cardiovascular Imaging
- Vol. 18 (11) , 1265-1269
Characterization of In-Stent Restenosis Using Photon-Counting Detector Computed Tomography
- 3 November 2025
- Published by Elsevier in JACC: Cardiovascular Imaging
- Vol. 18 (11) , 1265-1269
Characterization of In-Stent Restenosis Using Photon-Counting Detector Computed Tomography
- Open Access
- 22 April 2025
- Published by MDPI AG in Journal of Clinical Medicine
- Vol. 14 (9) , 2875
Coronary Calcium Scoring Using True and Virtual Non-Contrast Reconstructions on Photon-Counting CT with Differing Slice Increment: Impact on Calcium Severity Classifications
Background: Cardiovascular risk assessment relies heavily on coronary calcium scoring. With an emphasis on varying slice increments, this study investigates the effectiveness of true and virtual non-contrast reconstructions on photon-counting CT. Reconstruction methods’ effects on calcium severity classifications are critical to the improvement in imaging techniques. Methods: This study comprised 77 participants (mean age: 63 ± 10 years, 43% female), of whom 0 had a coronary artery calcium score (CACS) of zero. In contrast to true non-contrast (TNC) 3 × 3 mm, the reconstructions included TNC 3 × 1.5 mm, virtual non-contrast (VNC) 3 × 3 mm, and VNC 3 × 1.5 mm. Agatston units served as the basis for classifications into standard clinical diagnostic categories. Results: High concordance between acquisition types was revealed by interclass correlation values (0.97–0.99). Comparing TNC 3 × 1.5 mm reconstructions to their VNC counterparts, misclassifications were less common (Cohen Kappa = 0.94). (K = 0.83–0.85). Significant differences in the average calcium scores and rates of misclassification highlighted the impact of reconstruction methods on precise evaluations. Conclusions: VNC methods demonstrated high agreement; however, with a small rate of misclassifications as compared to the gold standard method. VNC CACS may help optimize workflows but may need differing cutoffs as compared to traditional methods.
- 22 April 2025
- Published by MDPI AG in Journal of Clinical Medicine
- Vol. 14 (9) , 2875
Open AccessCoronary Calcium Scoring Using True and Virtual Non-Contrast Reconstructions on Photon-Counting CT with Differing Slice Increment: Impact on Calcium Severity Classifications
Background: Cardiovascular risk assessment relies heavily on coronary calcium scoring. With an emphasis on varying slice increments, this study investigates the effectiveness of true and virtual non-contrast reconstructions on photon-counting CT. Reconstruction methods’ effects on calcium severity classifications are critical to the improvement in imaging techniques. Methods: This study comprised 77 participants (mean age: 63 ± 10 years, 43% female), of whom 0 had a coronary artery calcium score (CACS) of zero. In contrast to true non-contrast (TNC) 3 × 3 mm, the reconstructions included TNC 3 × 1.5 mm, virtual non-contrast (VNC) 3 × 3 mm, and VNC 3 × 1.5 mm. Agatston units served as the basis for classifications into standard clinical diagnostic categories. Results: High concordance between acquisition types was revealed by interclass correlation values (0.97–0.99). Comparing TNC 3 × 1.5 mm reconstructions to their VNC counterparts, misclassifications were less common (Cohen Kappa = 0.94). (K = 0.83–0.85). Significant differences in the average calcium scores and rates of misclassification highlighted the impact of reconstruction methods on precise evaluations. Conclusions: VNC methods demonstrated high agreement; however, with a small rate of misclassifications as compared to the gold standard method. VNC CACS may help optimize workflows but may need differing cutoffs as compared to traditional methods.