VKVijay Kumar

Vijay Kumar

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Vijay Kumar has a total of 12 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    PROVIMAPS: A Framework for Medical Image Data Provenance and Integrity in Medical Cyber-Physical Systems

    by Vijay Kumar, Kolin Paul

    This study presents PROVIMAPS, a framework for ensuring medical image data provenance and integrity in connected healthcare environments. The proposed approach introduces a software-based Device Fingerprint (DFP) generation method using intrinsic device parameters and SHA-256 hashing to uniquely identify the imaging source. The DFP is securely embedded into medical images using a DWT-based hybrid (DWT–DCT–SVD) watermarking technique, selected after a comparative analysis for its superior PSNR and SSIM performance across various medical image datasets. Additionally, an Image Average Intensity Profile (IAIP) is analyzed to detect image tampering and fused with the DFP for enhanced robustness. The combined signature ensures both device identification and content integrity. Comprehensive evaluation under various image attacks demonstrates the method's high robustness, computational efficiency, and resilience against manipulation. The PROVIMAPS framework offers a secure, low-cost, and scalable solution for maintaining trust in telemedicine, Internet of Medical Things (IoMT), eHealth, and Medical Cyber-Physical Systems (MCPS) applications, enabling reliable verification of image authenticity and source in distributed healthcare settings.

  • Open Access

    NetraDeep: An Integrated Deep Learning and Image Processing System for Precise Detection of Hard Exudates

    by Vatsal Agrawal, Vijay Kumar, Swati Sharma, Rohan Chawla, Kolin Paul

    Hard exudate (HE) is a common manifestation of various eye diseases, such as diabetic retinopathy (DR), and a prominent cause of vision loss and blindness. Researchers aim to visualize and quantify these exudates using deep learning (DL) and image processing (IP) models from retinal images. However, the requirement for a large number of labelled image datasets for DL models to work on diverse and poor-quality images makes this task challenging. To address this challenge, we introduce NetraDeep, a system that integrates data-driven DL and rule-based IP techniques for exudate segmentation. Our system uses IP models to detect and extract some features and assists DL models in detecting more advanced features and vice versa. The IP models are rule-based and use predefined rules to process images, while the DL models are data-driven and learn from the input data. NetraDeep provides visual and quantitative assessments while mitigating noise and other confounding factors such as artifacts and noise. The training of DL models of this system requires only a limited number of labelled fundus images from publicly available datasets. It provides accurate pixel-wise segmentation results on the public and private image datasets collected from local eye hospitals. Through extensive evaluation, our system achieved remarkable performance, with a dice coefficient of \(0.84\) for the public dataset and a rating of \(9.78\) and \(9.43\) out of 10, as corroborated by two medical experts with experience of more than 20 and 5 years, respectively, for the private image dataset.


  • Open Access

    Medical Image Data Provenance for Medical Cyber-Physical System

    by Vijay Kumar, Kolin Paul

    Continuous advancements in medical technology have led to the creation of affordable mobile imaging devices suitable for telemedicine and remote monitoring. However, the rapid examination of large populations poses challenges, including the risk of fraudulent practices by healthcare professionals and social workers exchanging unverified images via mobile applications. To mitigate these risks, this study proposes using watermarking techniques to embed a device fingerprint (DFP) into captured images, ensuring data provenance. The DFP, representing the unique attributes of the capturing device and raw image, is embedded into raw images before storage, thus enabling verification of image authenticity and source. Moreover, a robust remote validation method is introduced to authenticate images, enhancing the integrity of medical image data in interconnected healthcare systems. Through a case study on mobile fundus imaging, the effectiveness of the proposed framework is evaluated in terms of computational efficiency, image quality, security, and trustworthiness. This approach is suitable for a range of applications, including telemedicine, the Internet of Medical Things (IoMT), eHealth, and Medical Cyber-Physical Systems (MCPS) applications, providing a reliable means to maintain data provenance in diagnostic settings utilizing medical images or videos.


  • Open Access

    Fundus Imaging-Based Healthcare: Present and Future

    by Vijay Kumar, Kolin Paul

    A fundus image is a two-dimensional pictorial representation of the membrane at the rear of the eye that consists of blood vessels, the optical disc, optical cup, macula, and fovea. Ophthalmologists use it during eye examinations to screen, diagnose, and monitor the progress of retinal diseases or conditions such as diabetes, age-marked degeneration (AMD), glaucoma, retinopathy of prematurity (ROP), and many more ocular ailments. Developments in ocular optical systems, image acquisition, processing, and management techniques over the past few years have contributed to the use of fundus images to monitor eye conditions and other related health complications. This review summarizes the various state-of-the-art technologies related to the fundus imaging device, analysis techniques, and their potential applications for ocular diseases such as diabetic retinopathy, glaucoma, AMD, cataracts, and ROP. We also present potential opportunities for fundus imaging–based affordable, noninvasive devices for scanning, monitoring, and predicting ocular health conditions and providing other physiological information, for example, heart rate (HR), blood components, pulse rate, heart rate variability (HRV), retinal blood perfusion, and more. In addition, we present different types of technological, economical, and sociological factors that impact the growth of the fundus imaging–based technologies for health monitoring.


  • Open Access

    Deep Learning-assisted Retinopathy of Prematurity (ROP) Screening

    by Vijay Kumar, Het Patel, Kolin Paul, Shorya Azad

    Retinopathy of prematurity (ROP) is a leading cause of blindness in premature infants worldwide, particularly in developing countries. In this research, we propose a Deep Convolutional Neural Network (DCNN) and image processing-based approach for the automatic detection of retinal features, including the optical disc (OD) and retinal blood vessels (BV), as well as disease classification using a rule-based method for ROP patients. Our DCNN model uses YOLO-v5 for OD detection and either Pix2Pix or a U-Net for BV segmentation. We trained our DCNN models on publicly available fundus image datasets of size 1,117 and 288 for OD detection and BV segmentation, respectively. We evaluated our approach on a dataset of 439 preterm neonatal retinal images, testing for ROP Zone and 6 BV masks. Our proposed system achieved excellent results, with the OD detection module achieving an overall accuracy of 98.94% (when IoU 0.5) and the BV segmentation module achieving an accuracy of 96.69% and a Dice coefficient between 0.60 and 0.64. Moreover, our system accurately diagnosed ROP in Zone-1 with 88.23% accuracy. Our approach offers a promising solution for accurate ROP screening and diagnosis, particularly in low-resource settings, where it has the potential to improve healthcare outcomes.


  • Improved Blood Vessels Segmentation of Infant Retinal Image

    by Vijay Kumar, Het Patel, Shorya Azad, Kolin Paul

  • Open Access

    Device Fingerprinting for Cyber-Physical Systems: A Survey

    by Vijay Kumar, Kolin Paul

    The continued growth of the cyber-physical system (CPS) and Internet of Things technologies raises device security and monitoring concerns. For device identification, authentication, conditioning, and security, device fingerprint/fingerprinting (DFP) is increasingly used. However, finding the correct DFP features and sources to establish a unique and stable fingerprint is challenging. We present a state-of-the-art survey of DFP techniques for CPS device applications. We investigate the numerous DFP features, their origins, characteristics, and applications. Additionally, we discuss the DFP characteristics and their sources in detail, taking into account the physical contexts of various entities (i.e., machines, sensors, networks, and computational devices), as well as their software and applications for the CPS. We believe that this article will provide researchers and developers with insights into the DFP and its applications, sources, aggregation methods, and factors affecting its use in CPS domains.


  • Open Access

    Improved Blood Vessels Segmentation of Retinal Image of Infants

    by Vijay Kumar, Het Patel, Kolin Paul, Abhidnya Surve, Shorya Azad, Rohan Chawla


  • Open Access

    mNetra: A Fundoscopy based Optometer

    by Vijay Kumar, Kolin Paul

    Untreated refractive error in the eye is one of the leading causes of preventable blindness. The devices necessary for this is expensive and often requires skilled technicians to operate. In this paper, a common off the shelf ophthalmoscope has been modified and integrated with a smart phone to build an affordable optometer. The device has been tested on a statistically significant population with refractive error range from −8.00D to +3.50D. We found a reasonably good correlation with other prevalent methods of measuring refractive error in the eye.


  • Open Access

    Experimental Characterization of a Bearing-only Sensor for Use With the PHD Filter

    by Philip Dames, Vijay Kumar

    This report outlines the procedure and results of an experiment to characterize a bearing-only sensor for use with PHD filter. The resulting detection, measurement, and clutter models are used for hardware and simulated experiments with a team of mobile robots autonomously seeking an unknown number of objects of interest in an office environment.