STSherwin Chong Li Tan

Sherwin Chong Li Tan

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Sherwin Chong Li Tan has a total of 53 co-authors. Here are the top co-authors by number of shared publications:

  • Le Yang

    Institute of Materials Research and Engineering (IMRE), Agency for Science, Technology and Research (A*STAR), Singapore, Singapore

    8 shared publications
  • Yong Yu

    Institute of Materials Research and Engineering (IMRE), Agency for Science, Technology and Research (A*STAR), 2 Fusionopolis Way, Innovis #08-03, Singapore 138634, Republic of Singapore

    7 shared publications
  • Xin Ting Zheng

    Institute of Materials Research and Engineering (IMRE), Agency for Science Technology and Research (A*STAR), 2 Fusionopolis Way, Innovis #08-03, Singapore 138634, Republic of Singapore

    5 shared publications
  • Changyun Jiang

    Institute of Materials Research and Engineering (IMRE), Agency for Science, Technology and Research (A*Star), Singapore, Republic of Singapore

    4 shared publications
  • Wei Peng Goh

    Institute of Materials Research and Engineering (IMRE), Agency for Science, Technology and Research (A*Star), Singapore, Republic of Singapore

    4 shared publications
  • Jiajia Gao

    Institute of Materials Research and Engineering (IMRE), Agency for Science, Technology and Research (A*STAR), 2 Fusionopolis Way, Innovis #08-03, Singapore 138634, Republic of Singapore

    2 shared publications

Latest Publications

  • Ternary metal oxide engineering of screen-printed electrodes for wearable morphine sensing

    by Feng Liu, Shengnan Sun, Yong Yu, Xin Ting Zheng, Sherwin Chong Li Tan, Yiqin Wang, Veronica Gurung, Yi Ren, Hui Ru Tan, Zhi Wei Seh, et al.

  • Open Access

    Ionic liquid–regulated interfacial charge transport and asymmetric device architecture for high-performance electrochemiluminescence

    by Meilin Liu, Zelong Li, Bee Ru Tan, Jiexin Li, Nannan Li, Suchun Li, Sherwin Chong Li Tan, Jiajia Gao, Keeve Kristen Yiheng Kang, Yun Liu, et al.

    Electrochemiluminescence (ECL) devices are promising alternatives to organic light-emitting diodes (OLEDs) and light-emitting capacitors (LECs) due to their simple structure and lower operating voltage, yet realizing sufficient luminance for practical applications remains challenging. Here, we report a synergistic material-device strategy for ultrabright electrochemiluminescent (UBECL) devices. Decoupling anion and cation effects reveals ion-dependent control of interfacial charge-transfer dynamics and electrochemical stability in annihilation-ECL. An effective electrolyte with favorable photophysical and electrochemical properties, coupled with an asymmetric device architecture, enhances electrochemical reactivity and maximizes ECL brightness. UBECL device turns on at a low alternating voltage (±1.65 V) and operates under high-frequency driving. It achieves a maximum luminance of 1552 cd m −2 and 1.6 cd A −1 current efficiency, a 3.2- and 2-fold improvement over 1-ethyl-3-methylimidazolium bis (trifluoromethylsulfonyl) imide (EMIMTFSI)-based counterparts. Moreover, this flexible UBECL platform enables diverse optoelectronic applications, including multicolor devices with potential for dynamic sensing, real-time digital panels, and robust underwater solid-state devices. This strategy unlocks ultrabright, efficient, high-frequency operation for intuitive visual output.


  • Enhancing electrochemiluminescence through triplet state dynamics

    by Jiajia Gao, Badma Dylykov, Zelong Li, Sherwin Chong Li Tan, Yong Yu, Feng Liu, Veronica Gurung, Le Yang

    This review highlights emerging mechanisms that efficiently harness triplet exciton states to significantly enhance electrochemiluminescence (ECL) performance.


  • Stretchable Sweat Lactate Sensor with Dual‐Signal Read‐Outs

    by Sherwin Chong Li Tan, Yuetong Ning, Yong Yu, Wei Peng Goh, Changyun Jiang, Liyuan Liu, Xin Ting Zheng, Le Yang

    Innovations in wearable sweat sensors hold great promise to provide deeper insights into molecular level health information non‐invasively. Lactate, a key metabolite present in sweat, holds immense significance in assessing physiological conditions and performance in sports physiology and health sensing. This paper presents the development and characterization of stretchable electrodes with ultrahigh active surface area of 648 % for lactate sensing. The as‐printed stretchable electrodes were functionalized with an electron transfer layer comprising Toluidine Blue O and multi‐walled carbon nanotubes (MWCNTs), and an enzymatic layer consisting of lactate dehydrogenase with β‐Nicotinamide adenine dinucleotide as the cofactor for lactate selectivity. This sensor achieves a dual‐signal read‐out in which both electrochemical and fluorescence signals were obtained during lactate detection, demonstrating promising sensor performance in terms of sensitivity and reliability. We demonstrate the robustness of the dual‐signal sensor under simulated conditions of physical deformation and shifted excitation. Under these compromised conditions, the performance of the stretchable electrodes remained largely unaffected, showcasing their potential for robust and adaptable sensing platforms in wearable health monitoring applications.


  • Top Cited Papers

    Stretchable ionic–electronic bilayer hydrogel electronics enable in situ detection of solid-state epidermal biomarkers

    by Ruth Theresia Arwani, Sherwin Chong Li Tan, Archana Sundarapandi, Wei Peng Goh, Yin Liu, Fong Yew Leong, Weifeng Yang, Xin Ting Zheng, Yong Yu, Changyun Jiang, et al.

    Continuous and in situ detection of biomarkers in biofluids (for example, sweat) can provide critical health data but is limited by biofluid accessibility. Here we report a sensor design that enables in situ detection of solid-state biomarkers ubiquitously present on human skin. We deploy an ionic–electronic bilayer hydrogel to facilitate the sequential dissolution, diffusion and electrochemical reaction of solid-state analytes. We demonstrate continuous monitoring of water-soluble analytes (for example, solid lactate) and water-insoluble analytes (for example, solid cholesterol) with ultralow detection limits of 0.51 and 0.26 nmol cm−2, respectively. Additionally, the bilayer hydrogel electrochemical interface reduces motion artefacts by a factor of three compared with conventional liquid-sensing electrochemical interfaces. In a clinical study, solid-state epidermal biomarkers measured by our stretchable wearable sensors showed a high correlation with biomarkers in human blood and dynamically correlated with physiological activities. These results present routes to universal platforms for biomarker monitoring without the need for biofluid acquisition.


  • Co‐Encapsulating Enzymes and Carbon Dots in Metal–Organic Frameworks for Highly Stable and Sensitive Touch‐Based Sweat Sensors

    by Xin Ting Zheng, Melisa Wei Ning Leoi, Yong Yu, Sherwin Chong Li Tan, Naeem Nadzri, Wei Peng Goh, Changyun Jiang, Xi Ping Ni, Pei Wang, Meng Zhao, et al.

    Wearable metabolite sensors are often limited by easily denaturable enzymes that only allow short‐duration monitoring. Although encapsulating enzymes in metal–organic frameworks (MOFs) shows promise of long‐term enzyme protection, it is typically accompanied by significantly decreased activity due to increased diffusion barrier, steric hindrance for enzyme‐substrate binding, and poor enzyme‐electronic interface. Herein, the co‐encapsulation of enzymes and ultrasmall arginine‐derived carbon dots (Argdot) into a mesoporous Zeolitic Imidazolate Framework‐8 (mZIF‐8) matrix and the enhancement effect of Argdot on enzyme stability and activity, which consequently improves the electrochemical sensor's long‐term sensitivity are investigated. Specifically, the glucose oxidase (GOx)‐Argdot@mZIF‐8 nanocomposite consistently exhibits 40% higher electrochemical sensitivity compared to control GOx@mZIF‐8, an improvement similarly demonstrated with another model enzyme lactate oxidase (LOx). Furthermore, GOx‐Argdot@mZIF‐8 displays excellent stability, retaining 100% of initial sensitivity over 30 days of repeated testing at 37 °C. A touch‐based glucose sensor prototype is demonstrated as an excellent reusable sensor to monitor finger‐tip sweat glucose levels over one month at room temperature. This enzyme encapsulation strategy is not only useful for developing reusable sweat sensors with long‐term monitoring capability, but also promising to expand the industry use of enzymes under harsh conditions.


  • Skin‐Attachable Ink‐Dispenser‐Printed Paper Fluidic Sensor Patch for Colorimetric Sweat Analysis

    by Xin Ting Zheng, Wei Peng Goh, Yong Yu, Laura Sutarlie, Der Ying Chen, Sherwin Chong Li Tan, Changyun Jiang, Meng Zhao, Te Ba, Hongying Li, et al.

    In situ analysis of sweat biomarkers potentially provides noninvasive lifestyle monitoring and early diagnosis. Quantitative detection of sweat rate is crucial for thermoregulation and preventing heat injuries. Here, a skin‐attachable paper fluidic patch is reported for in situ colorimetric sensing of multiple sweat markers (pH, glucose, lactate, and uric acid) with concurrent sweat rate tracking. Two sets of fluidic patterns—multiplexed detection zones and a longitudinal sweat rate channel—are directly printed by an automated ink dispenser from a specially developed ceramic‐based ink. The ceramic ink thermal‐cures into an impervious barrier, confining sweat within the channels. The ceramic‐ink‐printed boundary achieves higher pattern resolution, prevents fluid leakage, attains pattern thermal stability, and resistant to organic solvents. The cellulose matrix of the detection zones is modified with nanoparticles to improve the color homogeneity and sweat sensor sensitivity. The sweat rate channel is made moisture sensitive by incorporating a metal‐salt‐based dye. The change in saturation/color of the detection zones and/or channels upon sweat addition can be visually detected or quantified by a smartphone camera. A cost‐effective way is provided to fabricate paper fluidic sensor patches, successfully demonstrating on‐body multiplexed evaluation of sweat analytes. Such skin wearables offer on‐site analysis, meaningful to an increasingly health‐conscious population.


  • Open Access

    Protein-Templated Metal Nanoclusters: Molecular-like Hybrids for Biosensing, Diagnostics and Pharmaceutics

    by Sherwin Chong Li Tan, Zhijian He, Guan Wang, Yong Yu, Le Yang

    The use of proteins as biomolecular templates to synthesize atomically precise metal nanoclusters has been gaining traction due to their appealing properties such as photoluminescence, good colloidal- and photostability and biocompatibility. The synergistic effect of using a protein scaffold and metal nanoclusters makes it especially attractive for biomedical applications. Unlike other reviews, we focus on proteins in general as the protective ligand for various metal nanoclusters and highlight their applications in the biomedical field. We first introduce the approaches and underlined principles in synthesizing protein-templated metal nanoclusters and summarize some of the typical proteins that have been used thus far. Afterwards, we highlight the key physicochemical properties and the characterization techniques commonly used for the size, structure and optical properties of protein-templated metal nanoclusters. We feature two case studies to illustrate the importance of combining these characterization techniques to elucidate the formation process of protein-templated metal nanoclusters. Lastly, we highlight the promising applications of protein-templated metal nanoclusters in three areas—biosensing, diagnostics and therapeutics.