JZJunyan Zhang

Junyan Zhang

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Junyan Zhang has a total of 24 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Ultra-High Contact Electrified Current Generation and Chemical Sensing at IL-Based Immiscible Liquid–Liquid Interface

    by Yunfei Deng, Junyan Zhang, Hongmian Qi, Shaobin Wen, Chengfa Wang, Zhe Yu, Mengqi Li

    Though the charge transfer efficiency of a liquid–liquid (L-L) nanogenerator is much higher than that of the solid–liquid and solid–solid counterparts, there is still much room for improving the level of interfacial charge transfer. In this study, a power generation system was designed using an ionic liquid (IL)-based immiscible L-L interface via the contact/separation mode. The maximum output electric current reaches as high as about 8.12 μA by contacting a saturated NaCl droplet with an immiscible IL droplet. The magnitude of the generated electric current signals increases with an increase in the ionic concentration of the NaCl solution, the droplet contact area, and the liquid volume of IL. Moreover, the magnitude of the signals varies slightly when the pH value is under 12 and increases sharply in strong alkaline conditions. A maximum instantaneous power output of about 82 nW was obtained with a 100 kΩ resistor in series. The IL-based immiscible L-L interface configuration has been proven to be capable of sensing metal ions at an ultra-low concentration via the contact/separation mode.

  • Compressive Sponge Electrodes Enabled Highly Sensitive Hybrid-Iontronic Pressure Sensor

    by Junyan Zhang, Haoran Wang, Wenshuai Tian, Dongqing Li, Jundong Zhang, Yongxin Song

    Most iontronic pressure sensors with planar metallic electrodes exhibit significant performance degradation in the medium to high-pressure range. To achieve high sensitivity in a broad sensing range, compressive porous electrodes (CPE) were employed to fabricate an ultrasensitive hybrid-iontronic pressure sensor. The sensor demonstrates an ultrahigh sensitivity of 198,160 kPa-1, a pressure resolution of 4.9 Pa, and a broad sensing range extending up to 160 kPa. Notably, the sensor maintains a nearly linear relationship between sensitivity and pressure within the sensing range of 37.5-92.5 kPa. This approach addresses the issue of significantly attenuated sensitivity across a broad pressure range, which arises from the limited thickness variation of planar electrodes. This composite structure, which integrates CPE with ion-loaded PU foam, offers a straightforward, cost-effective, and scalable method for producing ultrasensitive iontronic pressure sensors. The concept demonstration confirmed that CPE-based pressure sensors are capable of sensitively detecting subtle underwater mechanical stimuli, including vibrations and water waves.


  • Open Access

    Underwater Ionic Current Signal Sensing and Information Transmission by Contact-Induced Charge Transfer

    by Boru Su, Junyan Zhang, Yunfei Deng, Lin Chi

    Underwater ionic current signal sensing shows great potential for electric-field-sensing-based target detection, information transmission and communication. Nevertheless, it is still a challenging task. Herein, a self-powered underwater ionic current signal sensing system using contact-induced charge transfer is presented. The system mainly consists of a working electrode, a metal sheet and a sensing electrode that is immersed in electrolyte solution. Upon touching the working electrode with a metal sheet with a different work function, charge transfer occurs on the interface, and a corresponding ionic current is induced. The generated ionic current can be detected with the sensing electrode far away from the working electrode. It was found that the magnitude and direction of the generated ionic current are determined by the contact potential difference (CPD) between the working electrode and the contacting metal sheet. Additionally, the effects of water temperature, the ionic concentration of the electrolyte solution, electrode surface area and hydrostatic pressure are systematically investigated. The detected signal magnitude decreased with an increase in the distance between the working electrode and the sensing electrode. A proof-of-concept demonstration of underwater information transmission via Morse code with this method was successfully achieved.


  • Electrokinetic motion and viability assessment of algae with a polyethylene glycol–dextran interface

    by Runxin Xu, Junyan Zhang, Zhenhao Cao, Yongxin Song, Xiukun Xin

    At present, there is still limited report on the electrokinetic (EK) behavior of bioparticles at the interface of an aqueous two-phase system. In this paper, the EK motion and viability assessment of live algae mixed with the NaClO treated dead algae were carried out at the interface formed by polyethylene glycol (PEG)-rich phase and dextran (DEX)-rich phase in a straight microchannel. The experimental results show that both the live and dead algae at the PEG-DEX interface migrate from the negative electrode to the positive electrode, and the EK velocity of live algae at the interface is slightly larger than that of the dead ones with similar diameters. For either live or dead algae, the EK velocity at the interface decreases with the increase in diameter. A size-velocity curve was used to evaluate the viability of the algae. As most of the microorganisms in ballast water are algae, the method in this paper provides a promising way to detect and evaluate the live microorganism in treated ballast water of a ship.


  • Open Access

    Effects of Sodium Hypochlorite Treatment on the Chlorophyll Fluorescence in Photosystem Ii of Microalgae

    by Na Li, Zhen Liu, Pengcheng Wang, Kapur Suman, Junyan Zhang, Yongxin Song

    Chlorophyll fluorescence-based method shows great potentials for on-site assessing the vitality of algae in treated ship’s ballast water. However, there is very limited information on mechanism of chlorophyll fluorescence in photosystem II (PSII) after the treatment. In this paper, the effects of different NaClO concentrations (0.01, 0.04, 0.08, 0.12 and 0.15 mg/L) on the chlorophyll fluorescence kinetics and spectra of Chlorella vulgaris ( C. vulgaris ) and Platymonas helgolandica ( P. helgolandica ) were investigated. Experimental results show that both exposure time and dose are important factors that affect the toxicity of NaClO to microalgae. Further analyses showed that the maximum photochemical quantum yield of PSII, photochemical quenching and yield decreased rapidly with the increase in NaClO concentrations in the range of 0.04 mg/L to 0.15 mg/L, suggesting that NaClO seriously inhibited PSII reaction centers of algae. In addition, the maxima value of fluorescence at excitation wavelength still appeared near 437 nm and 468 nm under NaClO stress, indicating that the pigments for fluorescence produced by algae were mainly chlorophyll a and chlorophyll b antenna. Compared with chlorophyll a , the relative fluorescence intensity of chlorophyll b decreased significantly under NaClO treatments. According to the fluorescence emission spectra, treatment of NaClO resulted in a shift of the maximum peak of C. vulgaris and P. helgolandica from 685.2 nm to 681.9 nm and 685.2 nm to 680.5 within 6 h, respectively. It indicates that the structure of antenna light-absorbing pigments of PSII changed under NaClO stress. These results revealed that the chlorophyll fluorescence mechanism in PSII of damaged microalgae occurred variation, which was important for the reliable application of on-site analysis of ballast water indicator based on chlorophyll fluorescence detection.


  • Open Access

    Microfluidic and Nanofluidic Resistive Pulse Sensing: A Review

    by Yongxin Song, Junyan Zhang, Dongqing Li

    The resistive pulse sensing (RPS) method based on the Coulter principle is a powerful method for particle counting and sizing in electrolyte solutions. With the advancement of micro- and nano-fabrication technologies, microfluidic and nanofluidic resistive pulse sensing technologies and devices have been developed. Due to the unique advantages of microfluidics and nanofluidics, RPS sensors are enabled with more functions with greatly improved sensitivity and throughput and thus have wide applications in fields of biomedical research, clinical diagnosis, and so on. Firstly, this paper reviews some basic theories of particle sizing and counting. Emphasis is then given to the latest development of microfuidic and nanofluidic RPS technologies within the last 6 years, ranging from some new phenomena, methods of improving the sensitivity and throughput, and their applications, to some popular nanopore or nanochannel fabrication techniques. The future research directions and challenges on microfluidic and nanofluidic RPS are also outlined.