KVKyle Verdecchia

Kyle Verdecchia

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Kyle Verdecchia has a total of 5 co-authors. Here are the top co-authors by number of shared publications:

  • Keith St. Lawrence

    Imaging Program, Lawson Health Research Institute, London, Ontario N6A 4V2, Canada; Department of Medical Biophysics, University of Western Ontario, London, Ontario N6A 3K7, Canada

    2 shared publications
  • Laura B. Morrison

    Imaging Program, Lawson Health Research Institute, London, Ontario N6A 4V2, Canada; Department of Medical Biophysics, University of Western Ontario, London, Ontario N6A 3K7, Canada

    2 shared publications
  • Mamadou Diop

    Imaging Program, Lawson Health Research Institute, London, Ontario N6A 4V2, Canada; Department of Medical Biophysics, University of Western Ontario, London, Ontario N6A 3K7, Canada

    2 shared publications
  • Ting-Yim Lee

    Imaging Program, Lawson Health Research Institute, London, Ontario N6A 4V2, Canada; Department of Medical Biophysics, University of Western Ontario, London, Ontario N6A 3K7, Canada; Imaging Research Laboratories, Robarts Research Institute, London, Ontario N6G 2V4, Canada

    2 shared publications
  • Albert Lee

    Department of Medical Biophysics, University of Western Ontario, London, Ontario N6A 3K7, Canada

    1 shared publication

Latest Publications

  • Open Access

    Assessment of a multi-layered diffuse correlation spectroscopy method for monitoring cerebral blood flow in adults

    by Kyle Verdecchia, Mamadou Diop, Albert Lee, Laura B. Morrison, Ting-Yim Lee, Keith St. Lawrence

    Diffuse correlation spectroscopy (DCS) is a promising technique for brain monitoring as it can provide a continuous signal that is directly related to cerebral blood flow (CBF); however, signal contamination from extracerebral tissue can cause flow underestimations. The goal of this study was to investigate whether a multi-layered (ML) model that accounts for light propagation through the different tissue layers could successfully separate scalp and brain flow when applied to DCS data acquired at multiple source-detector distances. The method was first validated with phantom experiments. Next, experiments were conducted in a pig model of the adult head with a mean extracerebral tissue thickness of 9.8 ± 0.4 mm. Reductions in CBF were measured by ML DCS and computed tomography perfusion for validation; excellent agreement was observed by a mean difference of 1.2 ± 4.6% (CI95%: −31.1 and 28.6) between the two modalities, which was not significantly different.


  • Open Access

    Assessment of the best flow model to characterize diffuse correlation spectroscopy data acquired directly on the brain

    by Kyle Verdecchia, Mamadou Diop, Laura B. Morrison, Ting-Yim Lee, Keith St. Lawrence

    Diffuse correlation spectroscopy (DCS) is a non-invasive optical technique capable of monitoring tissue perfusion. The normalized temporal intensity autocorrelation function generated by DCS is typically characterized by assuming that the movement of erythrocytes can be modeled as a Brownian diffusion-like process instead of by the expected random flow model. Recently, a hybrid model, referred to as the hydrodynamic diffusion model, was proposed, which combines the random and Brownian flow models. The purpose of this study was to investigate the best model to describe autocorrelation functions acquired directly on the brain in order to avoid confounding effects of extracerebral tissues. Data were acquired from 11 pigs during normocapnia and hypocapnia, and flow changes were verified by computed tomography perfusion (CTP). The hydrodynamic diffusion model was found to provide the best fit to the autocorrelation functions; however, no significant difference for relative flow changes measured by the Brownian and hydrodynamic diffusion models was observed.