TLTaixiang Liu

Taixiang Liu

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Taixiang Liu has a total of 14 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Functional Optical Coherence Tomography of Rat Cortical Neurovascular Activation during Monopulse Electrical Stimulation with the Microelectrode Array

    by Lin Yao, Jin Huang, Taixiang Liu, Han Gu, Changpeng Li, Ke Yang, Hongwei Yan, Lin Huang, Xiaodong Jiang, Chengcheng Wang, et al.

    This paper presents a study to evoke rat cortical functional activities, including hemodynamic and neural tissue signal changes, by monopulse electrical stimulation with a microelectrode array using functional optical coherence tomography (fOCT). Based on the principal component analysis and fuzzy clustering method (PCA-FCM), the hemodynamic response of different size blood vessels in rat cortex are analyzed, showing that the hemodynamic response of the superficial large blood vessels is more concentrated. In the regions of neural tissue where blood vessels are removed, positive significant pixels (the intensity of the pixel for five consecutive frames is greater than the average value plus triple standard deviation) and negative significant pixels (the intensity of the pixel for five consecutive frames is less than the average value minus triple standard deviation) exist, and the averaged intensity signal responds rapidly with an onset time of ~20.8 ms. Furthermore, the hemodynamic response was delayed by ~3.5 s from the neural tissue response. fOCT can provide a label-free, large-scale and depth-resolved map of cortical neurovascular activation, which is a promising technology to monitor cortical small-scale neurovascular activities.

  • The transition from stress softening to stress hardening under cyclic loading induced by magnetic field for magneto-sensitive polymer gels

    by Yangguang Xu, Guojiang Liao, Canyang Zhang, Qiang Wan, Taixiang Liu

    Magneto-sensitive polymer gel (MSPG) is a kind of ferromagnetic particle filled smart polymer composite, whose magneto-mechanical coupling mechanism has attracted increasing attention in recent years. In this work, the magneto-induced rheological response of MSPG under cyclic shear loading was investigated. It was found that magnetic field is the critical reason for the transition from stress softening to stress hardening under cyclic loading. Besides, the particle concentration and temperature are the controlling factors in the structure optimization of MSPG in the presence of magnetic field. The magneto-induced hardening mechanism was further proposed based on the related experimental results.