Nazifi Sani Shuaibu
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Nazifi Sani Shuaibu has a total of 58 co-authors. Here are the top co-authors by number of shared publications:
- Xiaozhi Wang
College of Information Science and Electronic Engineering Zhejiang University Hangzhou 310027 China
9 shared publications Fengjian Chu
Zhejiang University College of Information Science and Electronic Engineering, Hangzhou, China
4 shared publicationsAmmar Muhammad Ibrahim
Department of Electrical Engineering, Aliko Dangote University of Science and Technology, Wudil, Kano State, 713101, Nigeria
2 shared publications- Aso Ali Abdalmohammed Shateri
College of Information Science and Electronic Engineering, Zhejiang University, Hangzhou 310027, China
2 shared publications - Fengling Zhuo
College of Information Science and Electronic Engineering, Zhejiang University, Hangzhou 310027, China
2 shared publications Gaosheng Zhao
Shanghai University School of Environmental and Chemical Engineering, Shanghai, China
2 shared publications
Latest Publications
- Open Access
- 9 July 2025
- Published by MDPI AG in Micromachines
- Vol. 16 (7) , 801
Constant High-Voltage Triboelectric Nanogenerator with Stable AC for Sustainable Energy Harvesting
Triboelectric nanogenerators (TENGs) hold significant potential for decentralized energy harvesting; however, their dependence on rotational mechanical energy often limits their ability to harness ubiquitous horizontal motion in real-world applications. Here, a single horizontal linear-to-rotational triboelectric nanogenerator (SHLR-TENG) is presented, designed to efficiently convert linear motion into rotational energy using a robust gear system, enabling a high voltage and reliable full cycle of alternating current (AC). The device features a radially patterned disk with triboelectric layers composed of polyimide. The SHLR-TENG achieves a peak-to-peak voltage of 1420 V, a short-circuit current of 117 µA, and an average power output of 41.5 mW, with a surface charge density of 110 µC/m2. Moreover, it demonstrates a power density per unit volume of 371.2 W·m−3·Hz−1. The device retains 80% efficiency after 1.5 million cycles, demonstrating substantial durability under mechanical stress. These properties enable the SHLR-TENG to directly power commercial LEDs and low-power circuits without the need for energy storage. This study presents an innovative approach to sustainable energy generation by integrating horizontal motion harvesting with rotational energy conversion. The compact and scalable design of the SHLR-TENG, coupled with its resilience to humidity (20–90% RH) and temperature fluctuations (10–70 °C), positions it as a promising next-generation energy source for Internet of Things (IoT) devices and autonomous systems.
- 9 July 2025
- Published by MDPI AG in Micromachines
- Vol. 16 (7) , 801
Open AccessConstant High-Voltage Triboelectric Nanogenerator with Stable AC for Sustainable Energy Harvesting
Triboelectric nanogenerators (TENGs) hold significant potential for decentralized energy harvesting; however, their dependence on rotational mechanical energy often limits their ability to harness ubiquitous horizontal motion in real-world applications. Here, a single horizontal linear-to-rotational triboelectric nanogenerator (SHLR-TENG) is presented, designed to efficiently convert linear motion into rotational energy using a robust gear system, enabling a high voltage and reliable full cycle of alternating current (AC). The device features a radially patterned disk with triboelectric layers composed of polyimide. The SHLR-TENG achieves a peak-to-peak voltage of 1420 V, a short-circuit current of 117 µA, and an average power output of 41.5 mW, with a surface charge density of 110 µC/m2. Moreover, it demonstrates a power density per unit volume of 371.2 W·m−3·Hz−1. The device retains 80% efficiency after 1.5 million cycles, demonstrating substantial durability under mechanical stress. These properties enable the SHLR-TENG to directly power commercial LEDs and low-power circuits without the need for energy storage. This study presents an innovative approach to sustainable energy generation by integrating horizontal motion harvesting with rotational energy conversion. The compact and scalable design of the SHLR-TENG, coupled with its resilience to humidity (20–90% RH) and temperature fluctuations (10–70 °C), positions it as a promising next-generation energy source for Internet of Things (IoT) devices and autonomous systems.
- Open Access
- 25 December 2024
- Published by MDPI AG in Micromachines
- Vol. 16 (1) , 11
Generating a Full Cycle of Alternative Current Using a Triboelectric Nanogenerator for Energy Harvesting
The triboelectric nanogenerator (TENG) has emerged as a promising technology for efficiently converting ambient mechanical energy into electrical energy. Among various designs, the disk-based rotational TENG has demonstrated significant potential, as it can continuously harvest energy in a sliding mode via a grating mechanism. However, horizontal mechanical energy is more common than rotational energy in many practical applications. Herein, the present study introduces a novel device: the double horizontal linear-to-rotational triboelectric nanogenerator (DHLR-TENG). This innovative approach utilizes a gear system to convert horizontal linear mechanical energy into electrical energy. The experimental results revealed that the DHLR-TENG produces a full cycle of alternating current (AC) when integrated into an electrical circuit. It consistently delivers robust performance with an open-circuit voltage of 544 V, a short-circuit current of 61.16 µA, and a maximum power output of 33.27 mW. Additionally, the device durability, capable of withstanding over 1,000,000 cycles, makes it highly effective for powering small electronic devices, such as charging capacitors and illuminating commercial LEDs. The DHLR-TENG’s versatility and efficiency mark it as a major advancement in energy harvesting, with broad implications for powering portable electronic devices in a wide range of environments.
- 25 December 2024
- Published by MDPI AG in Micromachines
- Vol. 16 (1) , 11
Open AccessGenerating a Full Cycle of Alternative Current Using a Triboelectric Nanogenerator for Energy Harvesting
The triboelectric nanogenerator (TENG) has emerged as a promising technology for efficiently converting ambient mechanical energy into electrical energy. Among various designs, the disk-based rotational TENG has demonstrated significant potential, as it can continuously harvest energy in a sliding mode via a grating mechanism. However, horizontal mechanical energy is more common than rotational energy in many practical applications. Herein, the present study introduces a novel device: the double horizontal linear-to-rotational triboelectric nanogenerator (DHLR-TENG). This innovative approach utilizes a gear system to convert horizontal linear mechanical energy into electrical energy. The experimental results revealed that the DHLR-TENG produces a full cycle of alternating current (AC) when integrated into an electrical circuit. It consistently delivers robust performance with an open-circuit voltage of 544 V, a short-circuit current of 61.16 µA, and a maximum power output of 33.27 mW. Additionally, the device durability, capable of withstanding over 1,000,000 cycles, makes it highly effective for powering small electronic devices, such as charging capacitors and illuminating commercial LEDs. The DHLR-TENG’s versatility and efficiency mark it as a major advancement in energy harvesting, with broad implications for powering portable electronic devices in a wide range of environments.
- Open Access
- 3 December 2024
- Published by Royal Society of Chemistry (RSC) in RSC Advances
- Vol. 14 (52) , 38634-38644
In situ analysis of heavy metals and halogenated compounds in reclaimed water using novel electrospray ionization combined with plasma ionization linear ion trap mass spectrometry
Water scarcity is a global concern that needs addressing through alternative sources. One of the approaches is the use of reclaimed water for irrigation. However, the presence of halogenated compounds and heavy metals in reclaimed water poses significant food safety threats. Therefore, a comprehensive characterization of these contaminants using a reliable method is essential. This study presents an innovative analytical technique that combines electrospray ionization (ESI) with microwave plasma ionization mass spectrometry (MPIMS), enabling the simultaneous detection of organic compounds and heavy metals. The plasma ionization process in metals exhibits novel features, unlike traditional methods, making it suitable for organic and metallic detection in complex matrices. This technique achieved a recovery rate of 78.5–123% and 79.93–119.50% for halogenated compounds and heavy metals, respectively. The limits of detection and quantification ranged from 1.5 ng mL−1 to 3.5 ng mL−1 and 4.5 ng mL−1 to 12.75 ng mL−1, respectively. Analysis of reclaimed water from three irrigation systems revealed concentrations of halogenated compounds and heavy metals below allowable levels set by national agencies, indicating manageable pollution risks. H-compounds, such as diuron and linuron, were prevalent in all samples, while zinc and lead showed higher levels in flood and sub-irrigation systems. Compared to traditional methods, ESI-MPIMS performs well and demonstrates high efficiency, good quantification, and high sensitivity in the analysis of real samples. This study shows that ESI-MPIMS is promising for on-site analysis of organic compounds and heavy metals in complex matrices and is suitable for water quality control and environmental quality assessment for pollutant screening.
- 3 December 2024
- Published by Royal Society of Chemistry (RSC) in RSC Advances
- Vol. 14 (52) , 38634-38644
Open AccessIn situ analysis of heavy metals and halogenated compounds in reclaimed water using novel electrospray ionization combined with plasma ionization linear ion trap mass spectrometry
Water scarcity is a global concern that needs addressing through alternative sources. One of the approaches is the use of reclaimed water for irrigation. However, the presence of halogenated compounds and heavy metals in reclaimed water poses significant food safety threats. Therefore, a comprehensive characterization of these contaminants using a reliable method is essential. This study presents an innovative analytical technique that combines electrospray ionization (ESI) with microwave plasma ionization mass spectrometry (MPIMS), enabling the simultaneous detection of organic compounds and heavy metals. The plasma ionization process in metals exhibits novel features, unlike traditional methods, making it suitable for organic and metallic detection in complex matrices. This technique achieved a recovery rate of 78.5–123% and 79.93–119.50% for halogenated compounds and heavy metals, respectively. The limits of detection and quantification ranged from 1.5 ng mL−1 to 3.5 ng mL−1 and 4.5 ng mL−1 to 12.75 ng mL−1, respectively. Analysis of reclaimed water from three irrigation systems revealed concentrations of halogenated compounds and heavy metals below allowable levels set by national agencies, indicating manageable pollution risks. H-compounds, such as diuron and linuron, were prevalent in all samples, while zinc and lead showed higher levels in flood and sub-irrigation systems. Compared to traditional methods, ESI-MPIMS performs well and demonstrates high efficiency, good quantification, and high sensitivity in the analysis of real samples. This study shows that ESI-MPIMS is promising for on-site analysis of organic compounds and heavy metals in complex matrices and is suitable for water quality control and environmental quality assessment for pollutant screening.
- Open Access
- 4 March 2024
- Published by Springer Nature in Environmental Sciences Europe
- Vol. 36 (1) , 1-14
Traceability tagging of volatile organic compound sources and their contributions to ozone formation in Suzhou using vehicle-based portable single-photon ionization mass spectrometry
Background: In recent decades, there has been an increasing global preoccupation with atmospheric volatile organic compounds (VOCs). Given the significant impact of VOCs as pollutants and essential precursors of ozone (O3) in urban and industrial areas, it is imperative to identify and quantify the sources of their emissions to facilitate the development and implementation of effective environmental control strategies. Methods: A mobile laboratory vehicle equipped with a single-photon ionization–time-of-flight mass spectrometer (SPI–TOFMS) and a navigation system was employed to establish the traceability of VOCs that contribute to the formation of ozone in Suzhou Industrial Park. The method exhibited a favorable detection limit of 0.090 ppbv, accompanied by a mass resolution of 1500 for the instrument and a correlation coefficient ≥ 0.990. A positive matrix factorization (PMF) model was utilized to determine the source appointment of the VOCs. Results: The study tentatively traced and identified the VOCs emissions source and their contribution to ozone formation in Suzhou. Using the PMF model, the sources of VOCs were profiled: three primary sources of VOCs were identified, namely, vehicular emissions, an industrial solvent, and biofuel combustion. Alkanes groups were found to be the most abundant VOCs species, accounting for 60% of the total VOCs, followed by aromatics and alkenes. Maximum incremental reactivity (MIR) quantifies the impact of photochemical reaction mechanism on the potential ozone formation. Conclusions: The findings of this study complement existing knowledge on the pollution status of atmospheric VOCs and highlight the correlation with ozone formation potential in Suzhou. The aforementioned sources were identified as the primary factors responsible for the pollution in Suzhou. The successful implementation of SPI–TOFMS has demonstrated a promising methodology that is well-suited for the real-time and online monitoring of VOCs in the atmosphere. In addition, a library for identifying VOC fingerprints from the same plant was established. This library serves as a comprehensive resource for establishing on-site VOC traceability, estimating source apportionment, and evaluating their impact on ozone formation.
- 4 March 2024
- Published by Springer Nature in Environmental Sciences Europe
- Vol. 36 (1) , 1-14
Open AccessTraceability tagging of volatile organic compound sources and their contributions to ozone formation in Suzhou using vehicle-based portable single-photon ionization mass spectrometry
Background: In recent decades, there has been an increasing global preoccupation with atmospheric volatile organic compounds (VOCs). Given the significant impact of VOCs as pollutants and essential precursors of ozone (O3) in urban and industrial areas, it is imperative to identify and quantify the sources of their emissions to facilitate the development and implementation of effective environmental control strategies. Methods: A mobile laboratory vehicle equipped with a single-photon ionization–time-of-flight mass spectrometer (SPI–TOFMS) and a navigation system was employed to establish the traceability of VOCs that contribute to the formation of ozone in Suzhou Industrial Park. The method exhibited a favorable detection limit of 0.090 ppbv, accompanied by a mass resolution of 1500 for the instrument and a correlation coefficient ≥ 0.990. A positive matrix factorization (PMF) model was utilized to determine the source appointment of the VOCs. Results: The study tentatively traced and identified the VOCs emissions source and their contribution to ozone formation in Suzhou. Using the PMF model, the sources of VOCs were profiled: three primary sources of VOCs were identified, namely, vehicular emissions, an industrial solvent, and biofuel combustion. Alkanes groups were found to be the most abundant VOCs species, accounting for 60% of the total VOCs, followed by aromatics and alkenes. Maximum incremental reactivity (MIR) quantifies the impact of photochemical reaction mechanism on the potential ozone formation. Conclusions: The findings of this study complement existing knowledge on the pollution status of atmospheric VOCs and highlight the correlation with ozone formation potential in Suzhou. The aforementioned sources were identified as the primary factors responsible for the pollution in Suzhou. The successful implementation of SPI–TOFMS has demonstrated a promising methodology that is well-suited for the real-time and online monitoring of VOCs in the atmosphere. In addition, a library for identifying VOC fingerprints from the same plant was established. This library serves as a comprehensive resource for establishing on-site VOC traceability, estimating source apportionment, and evaluating their impact on ozone formation.
- 7 December 2023
- Published by American Chemical Society (ACS) in ACS Applied Materials & Interfaces
- Vol. 15 (50) , 58976-58983
Microstructured Gel Polymer Electrolyte and an Interdigital Electrode-Based Iontronic Barometric Pressure Sensor with High Resolution over a Broad Range
We present a novel iontronic barometric pressure sensor based on a gel polymer electrolyte and interdigital electrodes with a much simpler structure than that of existing devices. By introducing high-density microstructures on the gel polymer electrolyte and one side electrode arrangement configuration, the developed sensor offers high performances with an ultrahigh resolution of 10 Pa, an ultrawide barometric pressure-response range from -92 to 7 kPa, a fast response time of ∼15 ms, and excellent long-term stability. The single pressure sensor is able to detect positive and negative barometric pressures without needing any additional means and can operate as a barometric altimeter with a resolution of about one-floor height. The performances of the sensors significantly surpass those of existing barometric pressure sensors. This work provides a new strategy for making high-performance barometric pressure sensors that are highly sought for commercial applications such as altitude detection, negative pressure ambulance, and consumer electronics.
- 7 December 2023
- Published by American Chemical Society (ACS) in ACS Applied Materials & Interfaces
- Vol. 15 (50) , 58976-58983
Microstructured Gel Polymer Electrolyte and an Interdigital Electrode-Based Iontronic Barometric Pressure Sensor with High Resolution over a Broad Range
We present a novel iontronic barometric pressure sensor based on a gel polymer electrolyte and interdigital electrodes with a much simpler structure than that of existing devices. By introducing high-density microstructures on the gel polymer electrolyte and one side electrode arrangement configuration, the developed sensor offers high performances with an ultrahigh resolution of 10 Pa, an ultrawide barometric pressure-response range from -92 to 7 kPa, a fast response time of ∼15 ms, and excellent long-term stability. The single pressure sensor is able to detect positive and negative barometric pressures without needing any additional means and can operate as a barometric altimeter with a resolution of about one-floor height. The performances of the sensors significantly surpass those of existing barometric pressure sensors. This work provides a new strategy for making high-performance barometric pressure sensors that are highly sought for commercial applications such as altitude detection, negative pressure ambulance, and consumer electronics.
- Open Access
- 23 October 2023
- Published by AIP Publishing in Applied Physics Letters
- Vol. 123 (17)
Memristors with tunable characteristics based on the tellurene/Nb-doped MoS2 heterojunction toward bio-realistic synaptic emulation
Emerging intelligence applications, such as brain-inspired and in-memory computing, require memory with faster read/write speeds, higher integration, and lower energy consumption. To tackle these challenges, memristors, a type of synaptic device, are considered ideal candidates due to their potential for emulating biological synaptic connections. In this study, a two-dimensional (2D) heterostructure of tellurene/Nb-doped MoS2 (MoS2:Nb) was used as the resistive switching layer to fabricate memristors. By varying the maximum working voltage, the fabricated device can switch between one and two-memory windows, which can be used to imitate the postsynaptic inhibition effect. This is attributed to the competition between the drift and diffusion of the S vacancy in the MoS2:Nb layer, which can modulate the contact Schottky barrier in the material interfaces. Furthermore, biological synapse effects, such as long-term depression and long-term potentiation, can be well mimicked by applying several voltage pulses to the device with good repeatability. This study advances the device physics for understanding the physical working mechanism of the 2D memristor, which can benefit the realization of bio-realistic neuromorphic computing systems based on such memristors.
- 23 October 2023
- Published by AIP Publishing in Applied Physics Letters
- Vol. 123 (17)
Open AccessMemristors with tunable characteristics based on the tellurene/Nb-doped MoS2 heterojunction toward bio-realistic synaptic emulation
Emerging intelligence applications, such as brain-inspired and in-memory computing, require memory with faster read/write speeds, higher integration, and lower energy consumption. To tackle these challenges, memristors, a type of synaptic device, are considered ideal candidates due to their potential for emulating biological synaptic connections. In this study, a two-dimensional (2D) heterostructure of tellurene/Nb-doped MoS2 (MoS2:Nb) was used as the resistive switching layer to fabricate memristors. By varying the maximum working voltage, the fabricated device can switch between one and two-memory windows, which can be used to imitate the postsynaptic inhibition effect. This is attributed to the competition between the drift and diffusion of the S vacancy in the MoS2:Nb layer, which can modulate the contact Schottky barrier in the material interfaces. Furthermore, biological synapse effects, such as long-term depression and long-term potentiation, can be well mimicked by applying several voltage pulses to the device with good repeatability. This study advances the device physics for understanding the physical working mechanism of the 2D memristor, which can benefit the realization of bio-realistic neuromorphic computing systems based on such memristors.
- 25 September 2023
- Published by Springer Nature in Environmental Science and Pollution Research
- Vol. 30 (49) , 108263-108273
Rapid analysis of pharmaceutical and personal care products by soft microwave-based plasma ionization—linear ion trap mass spectrometer (SMPI-LTQ) in natural water
In this study, a soft microwave plasma torch (SMPT) combined with a mass spectrometer (MS) was used for the first time as an analytical method to detect and analyze various pharmaceutical and personal care products (PPCPs) in aquatic environments without the need for sample pretreatment. For this purpose, ambient SMPT was used to generate plasma for ionizing the analyte molecules. Accordingly, nine PPCPs were identified by the SMPT-MS, and their identification was verified by collision-induced dissociation (CID). The technique’s performance was verified with known PPCP samples, and the limits of detection (LOD) and quantification (LOQ) obtained over a linear range of 50–1 μg/L were 1.56 to 2.81 and 2.07 to 3.62 μg/L, respectively, with the standard addition recovery rate falling between 87.14 and 115.16%. These results show that the method has excellent sensitivity and selectivity, suggesting that SMPT can rapidly and directly detect PPCPs in environmental water, making it a promising method for rapid water quality inspection.
- 25 September 2023
- Published by Springer Nature in Environmental Science and Pollution Research
- Vol. 30 (49) , 108263-108273
Rapid analysis of pharmaceutical and personal care products by soft microwave-based plasma ionization—linear ion trap mass spectrometer (SMPI-LTQ) in natural water
In this study, a soft microwave plasma torch (SMPT) combined with a mass spectrometer (MS) was used for the first time as an analytical method to detect and analyze various pharmaceutical and personal care products (PPCPs) in aquatic environments without the need for sample pretreatment. For this purpose, ambient SMPT was used to generate plasma for ionizing the analyte molecules. Accordingly, nine PPCPs were identified by the SMPT-MS, and their identification was verified by collision-induced dissociation (CID). The technique’s performance was verified with known PPCP samples, and the limits of detection (LOD) and quantification (LOQ) obtained over a linear range of 50–1 μg/L were 1.56 to 2.81 and 2.07 to 3.62 μg/L, respectively, with the standard addition recovery rate falling between 87.14 and 115.16%. These results show that the method has excellent sensitivity and selectivity, suggesting that SMPT can rapidly and directly detect PPCPs in environmental water, making it a promising method for rapid water quality inspection.
- Open Access
- 26 July 2023
- Published by MDPI AG in Chemosensors
- Vol. 11 (8) , 419
Mass Spectrometry-Based Biosensing and Biopsy Technology
Sensitive and accurate detection of biomolecules by multiplexed methods is important for disease diagnosis, drug research, and biochemical analysis. Mass spectrometry has the advantages of high sensitivity, high throughput, and high resolution, making it ideal for biomolecular sensing. As a result of the development of atmospheric pressure mass spectrometry, researchers have been able to use a variety of means to identify target biomolecules and recognize the converted signals by mass spectrometry. In this review, three main approaches and tools are summarized for mass spectrometry sensing and biopsy techniques, including array biosensing, probe/pen-based mass spectrometry, and other biosensor–mass spectrometry coupling techniques. Portability and practicality of relevant mass spectrometry sensing methods are reviewed, together with possible future directions to promote the advancement of mass spectrometry for target identification of biomolecules and rapid detection of real biological samples.
- 26 July 2023
- Published by MDPI AG in Chemosensors
- Vol. 11 (8) , 419
Open AccessMass Spectrometry-Based Biosensing and Biopsy Technology
Sensitive and accurate detection of biomolecules by multiplexed methods is important for disease diagnosis, drug research, and biochemical analysis. Mass spectrometry has the advantages of high sensitivity, high throughput, and high resolution, making it ideal for biomolecular sensing. As a result of the development of atmospheric pressure mass spectrometry, researchers have been able to use a variety of means to identify target biomolecules and recognize the converted signals by mass spectrometry. In this review, three main approaches and tools are summarized for mass spectrometry sensing and biopsy techniques, including array biosensing, probe/pen-based mass spectrometry, and other biosensor–mass spectrometry coupling techniques. Portability and practicality of relevant mass spectrometry sensing methods are reviewed, together with possible future directions to promote the advancement of mass spectrometry for target identification of biomolecules and rapid detection of real biological samples.
- Open Access
LC-MS/MS Based Volatile Organic Compound Biomarkers Analysis for Early Detection of Lung Cancer
(1) Background: lung cancer is the world’s deadliest cancer, but early diagnosis helps to improve the cure rate and thus reduce the mortality rate. Annual low-dose computed tomography (LD-CT) screening is an efficient lung cancer-screening program for a high-risk population. However, LD-CT has often been characterized by a higher degree of false-positive results. To meet these challenges, a volatolomic approach, in particular, the breath volatile organic compounds (VOCs) fingerprint analysis, has recently received increased attention for its application in early lung cancer screening thanks to its convenience, non-invasiveness, and being well tolerated by patients. (2) Methods: a LC-MS/MS-based volatolomics analysis was carried out according to P/N 5046800 standard based breath analysis of VOC as novel cancer biomarkers for distinguishing early-stage lung cancer from the healthy control group. The discriminatory accuracy of identified VOCs was assessed using subject work characterization and a random forest risk prediction model. (3) Results: the proposed technique has good performance compared with existing approaches, the differences between the exhaled VOCs of the early lung cancer patients before operation, three to seven days after the operation, as well as four to six weeks after operation under fasting and 1 h after the meal were compared with the healthy controls. The results showed that only 1 h after a meal, the concentration of seven VOCs, including 3-hydroxy-2-butanone (TG-4), glycolaldehyde (TG-7), 2-pentanone (TG-8), acrolein (TG-11), nonaldehyde (TG-19), decanal (TG-20), and crotonaldehyde (TG-22), differ significantly between lung cancer patients and control, with the invasive adenocarcinoma of the lung (IAC) having the most significant difference. (4) Conclusions: this novel, non-invasive approach can improve the detection rate of early lung cancer, and LC-MS/MS-based breath analysis could be a promising method for clinical application.
Open AccessLC-MS/MS Based Volatile Organic Compound Biomarkers Analysis for Early Detection of Lung Cancer
(1) Background: lung cancer is the world’s deadliest cancer, but early diagnosis helps to improve the cure rate and thus reduce the mortality rate. Annual low-dose computed tomography (LD-CT) screening is an efficient lung cancer-screening program for a high-risk population. However, LD-CT has often been characterized by a higher degree of false-positive results. To meet these challenges, a volatolomic approach, in particular, the breath volatile organic compounds (VOCs) fingerprint analysis, has recently received increased attention for its application in early lung cancer screening thanks to its convenience, non-invasiveness, and being well tolerated by patients. (2) Methods: a LC-MS/MS-based volatolomics analysis was carried out according to P/N 5046800 standard based breath analysis of VOC as novel cancer biomarkers for distinguishing early-stage lung cancer from the healthy control group. The discriminatory accuracy of identified VOCs was assessed using subject work characterization and a random forest risk prediction model. (3) Results: the proposed technique has good performance compared with existing approaches, the differences between the exhaled VOCs of the early lung cancer patients before operation, three to seven days after the operation, as well as four to six weeks after operation under fasting and 1 h after the meal were compared with the healthy controls. The results showed that only 1 h after a meal, the concentration of seven VOCs, including 3-hydroxy-2-butanone (TG-4), glycolaldehyde (TG-7), 2-pentanone (TG-8), acrolein (TG-11), nonaldehyde (TG-19), decanal (TG-20), and crotonaldehyde (TG-22), differ significantly between lung cancer patients and control, with the invasive adenocarcinoma of the lung (IAC) having the most significant difference. (4) Conclusions: this novel, non-invasive approach can improve the detection rate of early lung cancer, and LC-MS/MS-based breath analysis could be a promising method for clinical application.
- 23 December 2022
- Published by American Chemical Society (ACS) in Analytical Chemistry
- Vol. 95 (3) , 2004-2010
Catalyst-Free Oxidation Reactions in a Microwave Plasma Torch-Based Ion/Molecular Reactor: An Approach for Predicting the Atmospheric Oxidation of Pollutants
The atmospheric oxidation of chemicals has produced many new unpredicted pollutants. A microwave plasma torch-based ion/molecular reactor (MPTIR) interfacing an online mass spectrometer has been developed for creating and monitoring rapid oxidation reactions. Oxygen in the air is activated by the plasma into highly reactive oxygen radicals, thereby achieving oxidation of thioethers, alcohols, and various environmental pollutants on a millisecond scale without the addition of external oxidants or catalysts (6 orders of magnitude faster than bulk). The direct and real-time oxidation products of polycyclic aromatic hydrocarbons and p-phenylenediamines from the MPTIR match those of the long-term multistep environmental oxidative process. Meanwhile, two unreported environmental compounds were identified with an MPTIR and measured in the actual water samples, which demonstrates the considerable significance of the proposed device for both predicting the environmental pollutants (non-target screening) and studying the mechanism of atmospheric oxidative processes.
- 23 December 2022
- Published by American Chemical Society (ACS) in Analytical Chemistry
- Vol. 95 (3) , 2004-2010
Catalyst-Free Oxidation Reactions in a Microwave Plasma Torch-Based Ion/Molecular Reactor: An Approach for Predicting the Atmospheric Oxidation of Pollutants
The atmospheric oxidation of chemicals has produced many new unpredicted pollutants. A microwave plasma torch-based ion/molecular reactor (MPTIR) interfacing an online mass spectrometer has been developed for creating and monitoring rapid oxidation reactions. Oxygen in the air is activated by the plasma into highly reactive oxygen radicals, thereby achieving oxidation of thioethers, alcohols, and various environmental pollutants on a millisecond scale without the addition of external oxidants or catalysts (6 orders of magnitude faster than bulk). The direct and real-time oxidation products of polycyclic aromatic hydrocarbons and p-phenylenediamines from the MPTIR match those of the long-term multistep environmental oxidative process. Meanwhile, two unreported environmental compounds were identified with an MPTIR and measured in the actual water samples, which demonstrates the considerable significance of the proposed device for both predicting the environmental pollutants (non-target screening) and studying the mechanism of atmospheric oxidative processes.