LYLiu Yang

Liu Yang

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Liu Yang has a total of 7 co-authors. Here are the top co-authors by number of shared publications:

  • Lanlan Nie

    Huazhong University of Science and Technology

    1 shared publication
  • Ma bin

    School of Electrical Engineering, Wuhan University, Wuhan 430072, China

    1 shared publication
  • Ruizhi Zhang

    State Key Laboratory of Advanced Electromagnetic Engineering and Technology, School of Electrical and Electronic Engineering, Huazhong University of Science and Technology, Wuhan 430074, China

    1 shared publication
  • Wang Jianguo

    School of Electrical Engineering, Wuhan University, Wuhan 430072, China

    1 shared publication
  • Xi Chen

    State Key Laboratory of Advanced Electromagnetic Engineering and Technology, School of Electrical and Electronic Engineering, Huazhong University of Science and Technology, Wuhan 430074, China

    1 shared publication
  • Xinpei Lu

    School of Electrical and Electronic Engineering Huazhong University of Science and Technology Wuhan China

    1 shared publication

Latest Publications

  • Open Access

    Discharge Characteristics and Bactericidal Effects of a Self-Condensing Water-Electrode Plasma

    by Yang Liu, Ruizhi Zhang, Xi Chen, Xinpei Lu, Lanlan Nie

    This study proposes a self-condensing water-electrode plasma device in which ambient water vapor is condensed on a cooled needle-tip electrode within a strong electric-field region, forming continuously renewed water droplets, Taylor cones, or water-film interfaces that participate in the discharge process. The effects of ambient humidity, needle-tip temperature, and applied voltage on the self-condensation behavior were investigated. The discharge modes at different applied voltages and discharge gaps, the generation of reactive species, and the inactivation efficacy against Staphylococcus aureus were also analyzed. The results showed that increasing ambient humidity, decreasing the needle-tip temperature, and increasing the applied voltage all promoted water condensation at the needle tip. The electric field shortened the droplet formation time and reduced the droplet detachment size. As the applied voltage increased, the device sequentially underwent water condensation, electrospray, stable Taylor-cone, water-film discharge, and bare-electrode discharge stages, while the boundary voltage of each stage increased with the discharge gap. The ozone concentration remained below the instrument’s limit of detection during discharge with the self-condensing water electrode, whereas hydroxyl-radical generation was significantly enhanced. Compared with a conventional metal electrode, the self-condensing water electrode exhibited greater inactivation of S. aureus at the same applied voltage, with a more pronounced advantage under low-voltage conditions. These findings demonstrate that introducing a self-condensing water interface can regulate the local discharge morphology and reactive-species composition, providing a new strategy for developing low-temperature plasma sterilization technologies with low ozone production and high bactericidal activity.

  • Lightning current withstand capacity and voltage limiting characteristics of TVS

    by Liu Yang, Wang Jianguo, Zhou Wenjun, Ma bin

    Lightning current withstand and voltage limiting characteristics of three kinds of transient voltage suppressor (TVS) are tested with 8/20 mus impulse current generator, and the relation between related voltage and impulse peak power is analyzed. The results show that the lightning current withstand capacity is decreasing with the increase of related voltage of TVS, and the impulse peak power can not increase the lightning current withstand capacity effectively. The limiting voltage will increase and critical voltage limiting factor will decrease with related voltage of TVS. There are decentralization characteristics on limiting voltage between different TVS of the same related voltage. The suggestion for usage and checking the insulation coordination of TVS is proposed in the paper