Changlin Pang
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Changlin Pang has a total of 5 co-authors. Here are the top co-authors by number of shared publications:
Joel W. Burdick
Department of Mechanical Engineering, California Institute of Technology, Pasadena, CA 91125, USA
2 shared publicationsRichard A. Andersen
Division of Biology, California Institute of Technology, Pasadena, CA 91125, USA
2 shared publicationsYu-Chong Tai
Caltech Micromachining Lab, California Institute of Technology, Pasadena, CA 91125, USA
2 shared publicationsJorge G. Cham
Department of Mechanical Engineering, California Institute of Technology, Pasadena, CA 91125, USA
1 shared publicationSam Musallam
Division of Biology, California Institute of Technology, Pasadena, CA 91125, USA
1 shared publication
Latest Publications
- 1 January 2007
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 913-916
Electrolysis-based Parylene Balloon Actuators for Movable Neural Probes
In order to track a specific neuron and keep good sampling neural signals during chronic implantation, the neural probes are highly desired to have moving capability. This paper presents a novel electrolysis-based parylene balloon actuator fabricated with MEMS technology. The actuator is integrated with silicon probe to make it movable. A new fabrication technology has been developed to build a parylene balloon structure with silicon spring structure, electrolysis electrodes and electrolyte inside. By applying little current to electrolysis electrodes, high pressure is generated inside the parylene balloon by electrolysis. The spring structure is stretched with the parylene balloon expansion. Therefore the neural probe is moved by the actuation. The electrolysis actuator can generate large stain and pressure, requires modest electrical power and produces minimal heat. Due to the large volume expansion obtained via electrolysis, the small actuator can create a large force. The new electrolysis actuators for movable neural probes have been fabricated and validated.
- 1 January 2007
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 913-916
Electrolysis-based Parylene Balloon Actuators for Movable Neural Probes
In order to track a specific neuron and keep good sampling neural signals during chronic implantation, the neural probes are highly desired to have moving capability. This paper presents a novel electrolysis-based parylene balloon actuator fabricated with MEMS technology. The actuator is integrated with silicon probe to make it movable. A new fabrication technology has been developed to build a parylene balloon structure with silicon spring structure, electrolysis electrodes and electrolyte inside. By applying little current to electrolysis electrodes, high pressure is generated inside the parylene balloon by electrolysis. The spring structure is stretched with the parylene balloon expansion. Therefore the neural probe is moved by the actuation. The electrolysis actuator can generate large stain and pressure, requires modest electrical power and produces minimal heat. Due to the large volume expansion obtained via electrolysis, the small actuator can create a large force. The new electrolysis actuators for movable neural probes have been fabricated and validated.
- 1 January 2006
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1125-1128
Monolithic Silicon Probes with Flexible Parylene Cables for Neural Prostheses
This work presents the first parylene-insulated silicon probes, which are used for neural prostheses to record high-level cognitive neural signals. With parylene technology, our probes have several advantages compared with the current devices. First, instead of inorganic materials (e.g. silicon dioxide, silicon nitride), the electrodes and conduction traces on the probes are insulated by parylene, an easily-deposited polymer with mechanical flexibility and biocompatibility. As a result, the probes exhibit better electrical and mechanical properties. Second, flexible parylene cables are monolithically integrated with the probes, which arm the probes with very high flexibility to be easily assembled to a high density 3-D array and at the same time provide an ideal method to transmit neural signals through skull during chronic recording. The all dry fabrication process and a 4times4 probe array (64 electrodes) were demonstrated. The probes were successfully tested electrically and mechanically in rat cortex. Neural signals were properly recorded
- 1 January 2006
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1125-1128
Monolithic Silicon Probes with Flexible Parylene Cables for Neural Prostheses
This work presents the first parylene-insulated silicon probes, which are used for neural prostheses to record high-level cognitive neural signals. With parylene technology, our probes have several advantages compared with the current devices. First, instead of inorganic materials (e.g. silicon dioxide, silicon nitride), the electrodes and conduction traces on the probes are insulated by parylene, an easily-deposited polymer with mechanical flexibility and biocompatibility. As a result, the probes exhibit better electrical and mechanical properties. Second, flexible parylene cables are monolithically integrated with the probes, which arm the probes with very high flexibility to be easily assembled to a high density 3-D array and at the same time provide an ideal method to transmit neural signals through skull during chronic recording. The all dry fabrication process and a 4times4 probe array (64 electrodes) were demonstrated. The probes were successfully tested electrically and mechanically in rat cortex. Neural signals were properly recorded