Annamalai Annamalai
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Annamalai Annamalai has a total of 14 co-authors. Here are the top co-authors by number of shared publications:
- Mohamed Chouikha
Department of Electrical and Computer Engineering, College of Engineering, Prairie View A&M University, Prairie View, TX 77446, USA
11 shared publications - Samir Abood
Department of Electrical and Computer Engineering, College of Engineering, Prairie View A&M University, Prairie View, TX 77446, USA
10 shared publications - Turki Nejress
Department of Electrical and Computer Engineering, College of Engineering, Prairie View A&M University, Prairie View, TX 77446, USA
6 shared publications - Somayeh Soroush
Department of Electrical and Computer Engineering, College of Engineering, Prairie View A&M University, Prairie View, TX 77446, USA
4 shared publications - Dhadesugoor R. Vaman
ARO Center for Battlefield Communication (CeBCom), Department of Electrical & Computer Engineering, Prairie View A&M University, P. O. Box 519, Mail Stop 2520, Prairie View, TX 77446
2 shared publications - Jing Lu
ARO Center for Battlefield Communication (CeBCom), Department of Electrical & Computer Engineering, Prairie View A&M University, P. O. Box 519, Mail Stop 2520, Prairie View, TX 77446
2 shared publications
Latest Publications
- Open Access
- 2 October 2026
- Published by MDPI AG in Electronics
- Vol. 15 (19) , 4522
Next-Generation Modulation and Control of Power Electronic Systems: AI-Enabled Control, Digital Twins, Fault-Tolerant Operation, and Cyber-Physical Security
Power electronic systems are evolving from conventional fixed-function converters toward intelligent, adaptive, and cyber-physical energy-conversion platforms in which modulation, predictive control, artificial intelligence (AI), digital twins (DTs), fault diagnosis, and cybersecurity increasingly interact within a unified closed-loop architecture. This paper presents an integrated review and mathematical framework for next-generation modulation and control of power electronic systems, with an emphasis on advanced modulation, predictive control, AI-assisted adaptation, converter-oriented digital state estimation, fault-tolerant operation, and cyber-resilient control. The proposed framework links converter dynamics, state and parameter estimation, physical faults, cyber disturbances, supervisory anomaly assessment, and mode-dependent control reconfiguration. Two clearly separated validation levels complement the literature synthesis: experimentally measured operating data are used to establish physically representative operating conditions, whereas a dedicated converter-control model is used to evaluate closed-loop dynamic resilience. Under a combined physical/cyber disturbance, resilient reconfiguration reduced the post-event speed RMSE from 9.203 to 0.425 rad/s, the peak speed error from 29.999 to 1.724 rad/s, and the maximum current from 69.112 to 10.662 A, while eliminating 829 current-constraint violations observed without resilience. Across 100 randomized Monte Carlo trials, the mean post-event RMSE decreased from 11.951 ± 3.060 to 0.769 ± 0.291 rad/s, with the corresponding 95% confidence interval narrowing from 11.351–12.550 to 0.712–0.826 rad/s. The results provide simulation-based, closed-loop evidence that coordinated state estimation, anomaly assessment, and resilient reconfiguration can substantially limit disturbance propagation while maintaining converter-control performance under combined physical and cyber abnormalities. Hardware-in-the-loop and embedded real-time implementation remain subjects for future validation.
- 2 October 2026
- Published by MDPI AG in Electronics
- Vol. 15 (19) , 4522
Open AccessNext-Generation Modulation and Control of Power Electronic Systems: AI-Enabled Control, Digital Twins, Fault-Tolerant Operation, and Cyber-Physical Security
Power electronic systems are evolving from conventional fixed-function converters toward intelligent, adaptive, and cyber-physical energy-conversion platforms in which modulation, predictive control, artificial intelligence (AI), digital twins (DTs), fault diagnosis, and cybersecurity increasingly interact within a unified closed-loop architecture. This paper presents an integrated review and mathematical framework for next-generation modulation and control of power electronic systems, with an emphasis on advanced modulation, predictive control, AI-assisted adaptation, converter-oriented digital state estimation, fault-tolerant operation, and cyber-resilient control. The proposed framework links converter dynamics, state and parameter estimation, physical faults, cyber disturbances, supervisory anomaly assessment, and mode-dependent control reconfiguration. Two clearly separated validation levels complement the literature synthesis: experimentally measured operating data are used to establish physically representative operating conditions, whereas a dedicated converter-control model is used to evaluate closed-loop dynamic resilience. Under a combined physical/cyber disturbance, resilient reconfiguration reduced the post-event speed RMSE from 9.203 to 0.425 rad/s, the peak speed error from 29.999 to 1.724 rad/s, and the maximum current from 69.112 to 10.662 A, while eliminating 829 current-constraint violations observed without resilience. Across 100 randomized Monte Carlo trials, the mean post-event RMSE decreased from 11.951 ± 3.060 to 0.769 ± 0.291 rad/s, with the corresponding 95% confidence interval narrowing from 11.351–12.550 to 0.712–0.826 rad/s. The results provide simulation-based, closed-loop evidence that coordinated state estimation, anomaly assessment, and resilient reconfiguration can substantially limit disturbance propagation while maintaining converter-control performance under combined physical and cyber abnormalities. Hardware-in-the-loop and embedded real-time implementation remain subjects for future validation.
- Open Access
Experimentally Validated Adaptive Digital Twin for AI-Driven Fault Diagnosis and Predictive Health Monitoring of Multi-Machine Electric Drive Systems
This paper presents an adaptive digital twin framework for intelligent fault diagnosis and predictive health monitoring of a coupled multi-machine electric drive system. The experimental platform consists of two synchronous motors and a synchronous generator arranged in an interconnected electromechanical configuration and instrumented through the Lucas-Nülle laboratory platform. A physics-based digital representation is integrated with experimental measurements to reproduce the electrical and mechanical behavior of the drive system under different operating conditions. Physical-to-digital residuals are subsequently used for health assessment, fault detection, fault isolation, and intelligent classification. Experimental validation under five load conditions resulted in mean root-mean-square errors of 0.0391 N·m for torque, 0.1079 A for motor current, and 0.4555 V for motor voltage, with an overall mean normalized RMSE of 4.16%. The experimentally validated healthy-state digital twin was subsequently evaluated using model-based current-sensor, voltage-sensor, and torque-degradation scenarios. Channel-specific residual analysis successfully detected and isolated the abnormalities under investigation. Using digital twin residual features, an Ensemble classifier achieved a test accuracy of 98.61%, outperforming Artificial Neural Network (ANN) and Support Vector Machine (SVM) classifiers. In addition, a prognostic indicator was developed to characterize progressive degradation, with threshold crossings observed at simulated severities of 1.26%, 12.44%, and 17.37% for voltage-sensor deviation, torque degradation, and current-sensor deviation, respectively. The results demonstrate that integrating experimentally validated digital twin modeling, residual-based diagnostics, intelligent classification, and degradation monitoring provides a unified framework for condition assessment of coupled multi-machine electric-drive systems.
Open AccessExperimentally Validated Adaptive Digital Twin for AI-Driven Fault Diagnosis and Predictive Health Monitoring of Multi-Machine Electric Drive Systems
This paper presents an adaptive digital twin framework for intelligent fault diagnosis and predictive health monitoring of a coupled multi-machine electric drive system. The experimental platform consists of two synchronous motors and a synchronous generator arranged in an interconnected electromechanical configuration and instrumented through the Lucas-Nülle laboratory platform. A physics-based digital representation is integrated with experimental measurements to reproduce the electrical and mechanical behavior of the drive system under different operating conditions. Physical-to-digital residuals are subsequently used for health assessment, fault detection, fault isolation, and intelligent classification. Experimental validation under five load conditions resulted in mean root-mean-square errors of 0.0391 N·m for torque, 0.1079 A for motor current, and 0.4555 V for motor voltage, with an overall mean normalized RMSE of 4.16%. The experimentally validated healthy-state digital twin was subsequently evaluated using model-based current-sensor, voltage-sensor, and torque-degradation scenarios. Channel-specific residual analysis successfully detected and isolated the abnormalities under investigation. Using digital twin residual features, an Ensemble classifier achieved a test accuracy of 98.61%, outperforming Artificial Neural Network (ANN) and Support Vector Machine (SVM) classifiers. In addition, a prognostic indicator was developed to characterize progressive degradation, with threshold crossings observed at simulated severities of 1.26%, 12.44%, and 17.37% for voltage-sensor deviation, torque degradation, and current-sensor deviation, respectively. The results demonstrate that integrating experimentally validated digital twin modeling, residual-based diagnostics, intelligent classification, and degradation monitoring provides a unified framework for condition assessment of coupled multi-machine electric-drive systems.
- Open Access
- 14 September 2026
- Published by MDPI AG in Preprints.org
Next-Generation Modulation and Control of Power Electronic Systems: AI-Enabled Control, Digital Twins, Fault-Tolerant Operation, and Cyber-Physical Security
Power electronic systems are evolving from conventional fixed-function converters toward intelligent, adaptive, and cyber-physical energy-conversion platforms in which modulation, predictive control, artificial intelligence (AI), digital twins (DTs), fault diagnosis, and cybersecurity increasingly interact within a single closed-loop architecture. This paper presents an integrated review and unified mathematical framework for next-generation modulation and control of power electronic systems, with emphasis on advanced pulse-width and space-vector modulation, model predictive control (MPC), AI-assisted adaptation, DT-enabled monitoring, fault-tolerant operation, and cyber-resilient control. Unlike conventional reviews that address these technologies independently, the proposed framework links switched-converter dynamics, state and parameter estimation, residual-based diagnosis, physical faults, cyber disturbances, risk-adaptive control, and mode-dependent reconfiguration within a common formulation. The literature synthesis is complemented by an illustrative experimental case study that uses measured electrical machine operating data to evaluate the DT-based diagnostic and monitoring layers of the proposed architecture. Across five evaluated load conditions, the DT maintained a mean normalized root-mean-square error of 4.16%, with health indices remaining above 0.90, demonstrating consistent healthy-state tracking. Under representative injected sensor and torque-degradation scenarios, channel-specific residuals provided clear separation between healthy and abnormal conditions. AI-based residual classification achieved test accuracies above 97% across the evaluated classifiers, with the best-performing model reaching 98.61%. These experimentally grounded results support the feasibility of DT-assisted health assessment and intelligent diagnosis within the proposed cross-layer framework, while closed-loop integration of modulation, predictive control, fault-tolerant reconfiguration, and cyber-resilient operation remains an important direction for future experimental validation.
- 14 September 2026
- Published by MDPI AG in Preprints.org
Open AccessNext-Generation Modulation and Control of Power Electronic Systems: AI-Enabled Control, Digital Twins, Fault-Tolerant Operation, and Cyber-Physical Security
Power electronic systems are evolving from conventional fixed-function converters toward intelligent, adaptive, and cyber-physical energy-conversion platforms in which modulation, predictive control, artificial intelligence (AI), digital twins (DTs), fault diagnosis, and cybersecurity increasingly interact within a single closed-loop architecture. This paper presents an integrated review and unified mathematical framework for next-generation modulation and control of power electronic systems, with emphasis on advanced pulse-width and space-vector modulation, model predictive control (MPC), AI-assisted adaptation, DT-enabled monitoring, fault-tolerant operation, and cyber-resilient control. Unlike conventional reviews that address these technologies independently, the proposed framework links switched-converter dynamics, state and parameter estimation, residual-based diagnosis, physical faults, cyber disturbances, risk-adaptive control, and mode-dependent reconfiguration within a common formulation. The literature synthesis is complemented by an illustrative experimental case study that uses measured electrical machine operating data to evaluate the DT-based diagnostic and monitoring layers of the proposed architecture. Across five evaluated load conditions, the DT maintained a mean normalized root-mean-square error of 4.16%, with health indices remaining above 0.90, demonstrating consistent healthy-state tracking. Under representative injected sensor and torque-degradation scenarios, channel-specific residuals provided clear separation between healthy and abnormal conditions. AI-based residual classification achieved test accuracies above 97% across the evaluated classifiers, with the best-performing model reaching 98.61%. These experimentally grounded results support the feasibility of DT-assisted health assessment and intelligent diagnosis within the proposed cross-layer framework, while closed-loop integration of modulation, predictive control, fault-tolerant reconfiguration, and cyber-resilient operation remains an important direction for future experimental validation.
- Open Access
- 1 September 2026
- Published by MDPI AG in Preprints.org
Experimentally Validated Adaptive Digital Twin for AI-Driven Fault Diagnosis and Predictive Health Monitoring of Multi-Machine Electric Drive Systems
This paper presents an adaptive digital twin framework for intelligent fault diagnosis and predictive health monitoring of a coupled multi-machine electric drive system. The experimental platform consists of two synchronous motors and a synchronous generator arranged in an interconnected electromechanical configuration and instrumented through the Lucas-Nülle laboratory platform. A physics-based digital representation is integrated with experimental measurements to reproduce the electrical and mechanical behavior of the drive system under different operating conditions. Physical-to-digital residuals are subsequently used for health assessment, fault detection, fault isolation, and intelligent classification. Experimental validation under five load conditions resulted in mean root-mean-square errors of 0.0391 N·m for torque, 0.1079 A for motor current, and 0.4555 V for motor voltage, with an overall mean normalized RMSE of 4.16%. The experimentally validated healthy-state digital twin was subsequently evaluated using model-based current-sensor, voltage-sensor, and torque-degradation scenarios. Channel-specific residual analysis successfully detected and isolated the abnormalities under investigation. Using digital-twin residual features, an Ensemble classifier achieved a test accuracy of 98.61%, outperforming ANN and SVM classifiers. In addition, a prognostic indicator was developed to characterize progressive degradation, with threshold crossings observed at simulated severities of 1.26%, 12.44%, and 17.37% for voltage-sensor deviation, torque degradation, and current-sensor deviation, respectively. The results demonstrate that integrating experimentally validated digital-twin modeling, residual-based diagnostics, intelligent classification, and degradation monitoring provides a unified framework for condition assessment of coupled multi-machine electric-drive systems.
- 1 September 2026
- Published by MDPI AG in Preprints.org
Open AccessExperimentally Validated Adaptive Digital Twin for AI-Driven Fault Diagnosis and Predictive Health Monitoring of Multi-Machine Electric Drive Systems
This paper presents an adaptive digital twin framework for intelligent fault diagnosis and predictive health monitoring of a coupled multi-machine electric drive system. The experimental platform consists of two synchronous motors and a synchronous generator arranged in an interconnected electromechanical configuration and instrumented through the Lucas-Nülle laboratory platform. A physics-based digital representation is integrated with experimental measurements to reproduce the electrical and mechanical behavior of the drive system under different operating conditions. Physical-to-digital residuals are subsequently used for health assessment, fault detection, fault isolation, and intelligent classification. Experimental validation under five load conditions resulted in mean root-mean-square errors of 0.0391 N·m for torque, 0.1079 A for motor current, and 0.4555 V for motor voltage, with an overall mean normalized RMSE of 4.16%. The experimentally validated healthy-state digital twin was subsequently evaluated using model-based current-sensor, voltage-sensor, and torque-degradation scenarios. Channel-specific residual analysis successfully detected and isolated the abnormalities under investigation. Using digital-twin residual features, an Ensemble classifier achieved a test accuracy of 98.61%, outperforming ANN and SVM classifiers. In addition, a prognostic indicator was developed to characterize progressive degradation, with threshold crossings observed at simulated severities of 1.26%, 12.44%, and 17.37% for voltage-sensor deviation, torque degradation, and current-sensor deviation, respectively. The results demonstrate that integrating experimentally validated digital-twin modeling, residual-based diagnostics, intelligent classification, and degradation monitoring provides a unified framework for condition assessment of coupled multi-machine electric-drive systems.
- Open Access
Cyber-Physical Fault Diagnosis of Three-Phase Induction Motors Under Coordinated Network Attacks Using Explainable AI
The convergence of industrial communication networks and electric drive systems has increased the range of risks associated with induction motor operation, with abnormal motor operation potentially arising from either physical motor faults or malicious cyber operations. This study examines the impact of coordinated network attacks on a three-phase induction motor drive system in a real-time laboratory environment through a PLC–SCADA controlled environment. The following operating conditions were investigated experimentally: normal operation, stator disturbance, rotor abnormalities, false data injection attack, replay-based communication manipulation, and cyber-physical events. In the attack scenarios, significant differences were observed in motor speed, electromagnetic torque, stator current distortion, and communication latency compared with normal operating conditions. To differentiate between actual machine failures and cyber-induced anomalies, an explainable AI-based diagnostic framework was introduced that employs both electrical and network-layer features. Experimental results revealed that the proposed model achieved an overall classification accuracy of 93.17%, with precision and recall > 97% across most operating classes. When subjected to a coordinated attack, communication latency rose from 4.8 ms under normal operation to 37.6 ms, and the current THD increased from 3.2% to 14.7%. The proposed framework also successfully distinguished cyber-attack-induced abnormal behavior from genuine motor faults at a 96.9% detection rate, which is lower than that of conventional AI classifiers. Explainability analysis also showed that the top features that affect the diagnostic decision process were packet delay, stator current distortion, torque oscillation, and rotor speed deviation. The results demonstrate the necessity of incorporating cybersecurity awareness into intelligent fault diagnosis systems for modern induction motors in industrial cyber-physical environments.
Open AccessCyber-Physical Fault Diagnosis of Three-Phase Induction Motors Under Coordinated Network Attacks Using Explainable AI
The convergence of industrial communication networks and electric drive systems has increased the range of risks associated with induction motor operation, with abnormal motor operation potentially arising from either physical motor faults or malicious cyber operations. This study examines the impact of coordinated network attacks on a three-phase induction motor drive system in a real-time laboratory environment through a PLC–SCADA controlled environment. The following operating conditions were investigated experimentally: normal operation, stator disturbance, rotor abnormalities, false data injection attack, replay-based communication manipulation, and cyber-physical events. In the attack scenarios, significant differences were observed in motor speed, electromagnetic torque, stator current distortion, and communication latency compared with normal operating conditions. To differentiate between actual machine failures and cyber-induced anomalies, an explainable AI-based diagnostic framework was introduced that employs both electrical and network-layer features. Experimental results revealed that the proposed model achieved an overall classification accuracy of 93.17%, with precision and recall > 97% across most operating classes. When subjected to a coordinated attack, communication latency rose from 4.8 ms under normal operation to 37.6 ms, and the current THD increased from 3.2% to 14.7%. The proposed framework also successfully distinguished cyber-attack-induced abnormal behavior from genuine motor faults at a 96.9% detection rate, which is lower than that of conventional AI classifiers. Explainability analysis also showed that the top features that affect the diagnostic decision process were packet delay, stator current distortion, torque oscillation, and rotor speed deviation. The results demonstrate the necessity of incorporating cybersecurity awareness into intelligent fault diagnosis systems for modern induction motors in industrial cyber-physical environments.
- Open Access
- 1 July 2026
- Published by MDPI AG in Preprints.org
Cyber-Physical Fault Diagnosis of Three-Phase Induction Motors Under Coordinated Network Attacks Using Explainable AI
The convergence of industrial communication networks and electric drive systems has increased the range of risks associated with induction motor operation, with abnormal motor operation potentially arising from either physical motor faults or malicious cyber operations. This study examines the impact of coordinated network attacks on a three-phase induction motor drive system in a real-time laboratory environment through a PLC–SCADA controlled environment. The following operating conditions were investigated experimentally: normal operation, stator disturbance, rotor abnormalities, false data injection attack, replay-based communication manipulation, and cyber-physical events. In the attack scenarios, significant differences were observed in motor speed, electromagnetic torque, stator current distortion, and communication latency compared with normal operating conditions. To differentiate between actual machine failures and cyber-induced anomalies, an explainable AI-based diagnostic framework was introduced that employs both electrical and network-layer features. Experimental results revealed that the proposed model achieved an overall classification accuracy of 93.17%, with precision and recall> 97% across most operating classes. When subjected to a coordinated attack, communication latency rose from 4.8ms under normal operation to 37.6ms, and the current THD increased from 3.2% to 14.7%. The proposed framework also successfully distinguished cyber-attack-induced abnormal behavior from genuine motor faults at a 96.9% detection rate, which is lower than that of conventional AI classifiers. Explainability analysis also showed that the top features that affect the diagnostic decision process were packet delay, stator current distortion, torque oscillation, and rotor speed deviation. The results demonstrate the necessity of incorporating cybersecurity awareness into intelligent fault diagnosis systems for modern induction motors in industrial cyber-physical environments.
- 1 July 2026
- Published by MDPI AG in Preprints.org
Open AccessCyber-Physical Fault Diagnosis of Three-Phase Induction Motors Under Coordinated Network Attacks Using Explainable AI
The convergence of industrial communication networks and electric drive systems has increased the range of risks associated with induction motor operation, with abnormal motor operation potentially arising from either physical motor faults or malicious cyber operations. This study examines the impact of coordinated network attacks on a three-phase induction motor drive system in a real-time laboratory environment through a PLC–SCADA controlled environment. The following operating conditions were investigated experimentally: normal operation, stator disturbance, rotor abnormalities, false data injection attack, replay-based communication manipulation, and cyber-physical events. In the attack scenarios, significant differences were observed in motor speed, electromagnetic torque, stator current distortion, and communication latency compared with normal operating conditions. To differentiate between actual machine failures and cyber-induced anomalies, an explainable AI-based diagnostic framework was introduced that employs both electrical and network-layer features. Experimental results revealed that the proposed model achieved an overall classification accuracy of 93.17%, with precision and recall> 97% across most operating classes. When subjected to a coordinated attack, communication latency rose from 4.8ms under normal operation to 37.6ms, and the current THD increased from 3.2% to 14.7%. The proposed framework also successfully distinguished cyber-attack-induced abnormal behavior from genuine motor faults at a 96.9% detection rate, which is lower than that of conventional AI classifiers. Explainability analysis also showed that the top features that affect the diagnostic decision process were packet delay, stator current distortion, torque oscillation, and rotor speed deviation. The results demonstrate the necessity of incorporating cybersecurity awareness into intelligent fault diagnosis systems for modern induction motors in industrial cyber-physical environments.
- Open Access
- 20 May 2026
- Published by MDPI AG in Electronics
- Vol. 15 (10) , 2197
Privacy-Preserving Federated Cybersecurity Analytics for Smart-Grid SCADA: Maintaining Controllability and Observability Under Coordinated Attacks
Ensuring resilient controllability and observability in SCADA-based smart grids under coordinated cyberattacks remains a critical and unresolved challenge in modern cyber-physical power systems. This paper investigates the impact of coordinated cyberattacks on the stability and monitoring capabilities of SCADA-based smart-grid systems within a controlled cyber-physical environment. An active cyber-physical testbed representing a multi-bus power system was created to analyze how attacks targeting communication channels affect controllability and observability. Several attack scenarios were implemented, including remote access attacks via Secure Shell (SSH), Modbus/TCP flooding, and ICMP-based attacks, to monitor their impact on control actions, communication reliability, and system responsiveness. To address these vulnerabilities, a SCADA-based cybersecurity monitoring system was implemented within the controlled testbed environment. The system analyzes SCADA operational logs from smart grid devices while packet-level network traffic is captured and examined using monitoring tools such as Wireshark. A central monitoring layer coordinates system-wide attack detection and response. System resilience was evaluated using controllability and observability matrix rank analysis, together with dynamic stability metrics during attack conditions. Experimental and simulation results show that coordinated cyberattacks significantly degrade system performance, with the average delay rising from 12 ms to 210 ms, the packet loss rate increasing to 15.5%, and the command execution error rate reaching 40%. Furthermore, the ranks of the controllability and observability matrices dropped from 4 to 2, indicating a critical partial loss of the system’s control and monitoring capabilities. In this work, the federated-learning-based component is explored as a distributed, privacy-preserving cybersecurity monitoring framework for anomaly detection and observability enhancement using SCADA-derived datasets, rather than as a fully integrated real-time SCADA operational control mechanism. At the same time, the attack’s impact on electrical properties remained limited to less than 2%.
- 20 May 2026
- Published by MDPI AG in Electronics
- Vol. 15 (10) , 2197
Open AccessPrivacy-Preserving Federated Cybersecurity Analytics for Smart-Grid SCADA: Maintaining Controllability and Observability Under Coordinated Attacks
Ensuring resilient controllability and observability in SCADA-based smart grids under coordinated cyberattacks remains a critical and unresolved challenge in modern cyber-physical power systems. This paper investigates the impact of coordinated cyberattacks on the stability and monitoring capabilities of SCADA-based smart-grid systems within a controlled cyber-physical environment. An active cyber-physical testbed representing a multi-bus power system was created to analyze how attacks targeting communication channels affect controllability and observability. Several attack scenarios were implemented, including remote access attacks via Secure Shell (SSH), Modbus/TCP flooding, and ICMP-based attacks, to monitor their impact on control actions, communication reliability, and system responsiveness. To address these vulnerabilities, a SCADA-based cybersecurity monitoring system was implemented within the controlled testbed environment. The system analyzes SCADA operational logs from smart grid devices while packet-level network traffic is captured and examined using monitoring tools such as Wireshark. A central monitoring layer coordinates system-wide attack detection and response. System resilience was evaluated using controllability and observability matrix rank analysis, together with dynamic stability metrics during attack conditions. Experimental and simulation results show that coordinated cyberattacks significantly degrade system performance, with the average delay rising from 12 ms to 210 ms, the packet loss rate increasing to 15.5%, and the command execution error rate reaching 40%. Furthermore, the ranks of the controllability and observability matrices dropped from 4 to 2, indicating a critical partial loss of the system’s control and monitoring capabilities. In this work, the federated-learning-based component is explored as a distributed, privacy-preserving cybersecurity monitoring framework for anomaly detection and observability enhancement using SCADA-derived datasets, rather than as a fully integrated real-time SCADA operational control mechanism. At the same time, the attack’s impact on electrical properties remained limited to less than 2%.
- Open Access
- 7 April 2026
- Published by MDPI AG in Preprints.org
Privacy-Preserving Federated Cybersecurity Analytics for Smart-Grid SCADA: Maintaining Controllability and Observability Under Coordinated Attacks
Ensuring resilient controllability and observability in SCADA-based smart grids under coordinated cyberattacks remains a critical and unresolved challenge in modern cyber-physical power systems. This paper demonstrates the impact of coordinated cyberattacks on the stability and monitoring capabilities of SCADA-based smart grid systems in a controlled cyber-physical environment. An active cyber-physical testbed representing a multi-bus power system was created to be able to analyze how attacks targeting communication channels affect controllability and observability. Several attack scenarios were implemented, including remote access attacks via Secure Shell (SSH), Modbus/TCP flooding, and ICMP-based attacks, to monitor their impact on control actions, measure accuracy, and assess system responsiveness. To address these vulnerabilities, a SCADA-based cybersecurity monitoring system was implemented within the controlled testbed environment. The system analyzes SCADA operational logs from smart grid devices while packet-level network traffic is captured and examined using monitoring tools such as Wireshark. A central monitoring layer coordinates system-wide attack detection and response. System resilience was evaluated using controllability and observability matrix rank analysis, together with dynamic stability metrics during attack conditions. Experimental and simulation results show that coordinated cyberattacks lead to a significant degradation in system performance, with the average delay rising from 12 ms to 210 ms, the packet loss rate increasing to 15.5%, and the command execution error rate reaching 40%. Furthermore, the ranks of the controllability and observability matrices dropped from 4 to 2, indicating a critical partial loss of the systemʹs control and monitoring capabilities. At the same time, the attackʹs impact on electrical properties remained limited to less than 2%.
- 7 April 2026
- Published by MDPI AG in Preprints.org
Open AccessPrivacy-Preserving Federated Cybersecurity Analytics for Smart-Grid SCADA: Maintaining Controllability and Observability Under Coordinated Attacks
Ensuring resilient controllability and observability in SCADA-based smart grids under coordinated cyberattacks remains a critical and unresolved challenge in modern cyber-physical power systems. This paper demonstrates the impact of coordinated cyberattacks on the stability and monitoring capabilities of SCADA-based smart grid systems in a controlled cyber-physical environment. An active cyber-physical testbed representing a multi-bus power system was created to be able to analyze how attacks targeting communication channels affect controllability and observability. Several attack scenarios were implemented, including remote access attacks via Secure Shell (SSH), Modbus/TCP flooding, and ICMP-based attacks, to monitor their impact on control actions, measure accuracy, and assess system responsiveness. To address these vulnerabilities, a SCADA-based cybersecurity monitoring system was implemented within the controlled testbed environment. The system analyzes SCADA operational logs from smart grid devices while packet-level network traffic is captured and examined using monitoring tools such as Wireshark. A central monitoring layer coordinates system-wide attack detection and response. System resilience was evaluated using controllability and observability matrix rank analysis, together with dynamic stability metrics during attack conditions. Experimental and simulation results show that coordinated cyberattacks lead to a significant degradation in system performance, with the average delay rising from 12 ms to 210 ms, the packet loss rate increasing to 15.5%, and the command execution error rate reaching 40%. Furthermore, the ranks of the controllability and observability matrices dropped from 4 to 2, indicating a critical partial loss of the systemʹs control and monitoring capabilities. At the same time, the attackʹs impact on electrical properties remained limited to less than 2%.
- 27 April 2025
- Published by Springer Nature
- p. 155-165
Detection of Network Anomalies Using Unsupervised and Reinforcement Learning Models
- 27 April 2025
- Published by Springer Nature
- p. 155-165
Detection of Network Anomalies Using Unsupervised and Reinforcement Learning Models
- Open Access
Fault Diagnostics of Synchronous Motor Based on Artificial Intelligence
Electrical motors and drives are the unseen forces driving our modern world, powering everything from electric vehicles to industrial machinery. The efficiency, precision, and sustainability of these systems are very important. Unexpected motor failures can cause major disruptions, risk human lives, and cause costly downtime. This research aims to improve the efficiency and performance of three-phase synchronous machines using Artificial Intelligence (AI) strategies. The research uses real-time data and optimization techniques to explore advanced diagnostic techniques, fault diagnosis, fault tolerance, and condition monitoring schemes to enhance safety, reliability, and performance in electric synchronous operations. Experimental results demonstrated that AI-driven methods achieve higher fault detection accuracy than traditional techniques. The findings highlight the potential of AI in improving the reliability of industrial synchronous motors.
Open AccessFault Diagnostics of Synchronous Motor Based on Artificial Intelligence
Electrical motors and drives are the unseen forces driving our modern world, powering everything from electric vehicles to industrial machinery. The efficiency, precision, and sustainability of these systems are very important. Unexpected motor failures can cause major disruptions, risk human lives, and cause costly downtime. This research aims to improve the efficiency and performance of three-phase synchronous machines using Artificial Intelligence (AI) strategies. The research uses real-time data and optimization techniques to explore advanced diagnostic techniques, fault diagnosis, fault tolerance, and condition monitoring schemes to enhance safety, reliability, and performance in electric synchronous operations. Experimental results demonstrated that AI-driven methods achieve higher fault detection accuracy than traditional techniques. The findings highlight the potential of AI in improving the reliability of industrial synchronous motors.