N. Vinoth Kumar
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
N. Vinoth Kumar has a total of 20 co-authors. Here are the top co-authors by number of shared publications:
V. Kumar Chinnaiyan
KPR Institute of Engineering and Technology, Coimbatore, India
6 shared publicationsM. Pradish
Central Power Research Institute, Bangalore, INDIA
3 shared publications- Ranganathan S
Department of Electronics & Instrumentation Engineering, Kumaraguru College of Technology, Coimbatore, Tamil Nadu, India
2 shared publications - Arumugam Paventhan
ERNET India
1 shared publication Divekar
Central Power Research Institute, Bangalore-560080, India
1 shared publication- Kuldeep Chouhan
Department of Computer Science and Applications, Sharda School of Engineering and Technology, India
1 shared publication
Latest Publications
- 14 November 2026
- Published by IWA Publishing in Water Supply
Machine learning-based leak detection and predefined leak-location classification in water distribution systems using experimental pressure and vibration data
Leakage in water distribution systems can cause substantial water loss, infrastructure deterioration, and operational challenges, motivating data-driven detection and localization methods. This study investigates experimentally acquired pressure and vibration measurements from a laboratory water-distribution pipeline using a unified machine-learning framework. The approximately 6.0-m test loop used nominal 1-inch pipeline sections, a 1.3-kW, 2,700-rpm circulation pump, an inlet valve maintained at approximately 70% open, and an observed no-leak operating pressure of approximately 1 bar. Three artificial leakage locations used 8-mm openings. Three sensing configurations – pressure-only, vibration-only, and pressure–vibration fusion – were evaluated using Random Forest, XGBoost, LightGBM, and Multi-Layer Perceptron models with engineered time- and frequency-domain features. Binary leak detection and predefined single-leak-location classification were evaluated separately using fixed held-out test partitions. The majority-class baseline achieved 85.0% accuracy, demonstrating that accuracy alone can be misleading under class imbalance. Localization was substantially more challenging, with a maximum accuracy of 40.0% and macro-F1 of 38.89%. Statistical comparisons did not identify significant pairwise differences after correction. The study provides an offline experimental proof-of-concept requiring independent-run and field-scale validation.
- 14 November 2026
- Published by IWA Publishing in Water Supply
Machine learning-based leak detection and predefined leak-location classification in water distribution systems using experimental pressure and vibration data
Leakage in water distribution systems can cause substantial water loss, infrastructure deterioration, and operational challenges, motivating data-driven detection and localization methods. This study investigates experimentally acquired pressure and vibration measurements from a laboratory water-distribution pipeline using a unified machine-learning framework. The approximately 6.0-m test loop used nominal 1-inch pipeline sections, a 1.3-kW, 2,700-rpm circulation pump, an inlet valve maintained at approximately 70% open, and an observed no-leak operating pressure of approximately 1 bar. Three artificial leakage locations used 8-mm openings. Three sensing configurations – pressure-only, vibration-only, and pressure–vibration fusion – were evaluated using Random Forest, XGBoost, LightGBM, and Multi-Layer Perceptron models with engineered time- and frequency-domain features. Binary leak detection and predefined single-leak-location classification were evaluated separately using fixed held-out test partitions. The majority-class baseline achieved 85.0% accuracy, demonstrating that accuracy alone can be misleading under class imbalance. Localization was substantially more challenging, with a maximum accuracy of 40.0% and macro-F1 of 38.89%. Statistical comparisons did not identify significant pairwise differences after correction. The study provides an offline experimental proof-of-concept requiring independent-run and field-scale validation.
- 19 August 2026
- Published by IWA Publishing in Water Practice & Technology
- Vol. 21 (9) , 4675-4699
Rule-based hydraulic severity classification strategy for adaptive pressure management in water distribution networks
Water leakage significantly affects the hydraulic performance, operational efficiency, and service reliability of water distribution networks. This study proposes a Hydraulic Severity Classification Strategy (HSCS) for adaptive pressure management using EPANET-based hydraulic simulation. The proposed framework integrates multi-scenario leak simulation, engineering-based hydraulic severity assessment, and a transparent rule-based control strategy to support computationally efficient operational decision-making. The benchmark EPANET Net3 water distribution network was evaluated under thirty leak scenarios generated from representative leak locations and leak magnitudes, from which twenty-three representative scenarios were selected for detailed validation. Hydraulic performance was assessed using pressure root mean square error (RMSE), pressure deviation, pressure recovery, service-pressure deficiency, and hydraulic severity indicators. The calculated Hydraulic Severity Score was used to classify leak scenarios and automatically determine adaptive pump speed adjustments without iterative optimization. The proposed HSCS reduced the average pressure RMSE from 1.2923 to 1.2538 m, achieving an average improvement of 2.28%, while providing an average pressure recovery of 1.378 m with a mean pump speed factor of 1.0346. Statistical validation further confirmed the consistency and reliability of the proposed framework. The results demonstrate that HSCS provides a transparent, computationally efficient, and practical engineering decision-support tool for adaptive pressure management in water distribution networks.
- 19 August 2026
- Published by IWA Publishing in Water Practice & Technology
- Vol. 21 (9) , 4675-4699
Rule-based hydraulic severity classification strategy for adaptive pressure management in water distribution networks
Water leakage significantly affects the hydraulic performance, operational efficiency, and service reliability of water distribution networks. This study proposes a Hydraulic Severity Classification Strategy (HSCS) for adaptive pressure management using EPANET-based hydraulic simulation. The proposed framework integrates multi-scenario leak simulation, engineering-based hydraulic severity assessment, and a transparent rule-based control strategy to support computationally efficient operational decision-making. The benchmark EPANET Net3 water distribution network was evaluated under thirty leak scenarios generated from representative leak locations and leak magnitudes, from which twenty-three representative scenarios were selected for detailed validation. Hydraulic performance was assessed using pressure root mean square error (RMSE), pressure deviation, pressure recovery, service-pressure deficiency, and hydraulic severity indicators. The calculated Hydraulic Severity Score was used to classify leak scenarios and automatically determine adaptive pump speed adjustments without iterative optimization. The proposed HSCS reduced the average pressure RMSE from 1.2923 to 1.2538 m, achieving an average improvement of 2.28%, while providing an average pressure recovery of 1.378 m with a mean pump speed factor of 1.0346. Statistical validation further confirmed the consistency and reliability of the proposed framework. The results demonstrate that HSCS provides a transparent, computationally efficient, and practical engineering decision-support tool for adaptive pressure management in water distribution networks.
- 9 August 2018
- Published by Taylor & Francis in Electric Power Components and Systems
- Vol. 46 (13) , 1432-1447
A Recommended Cascaded Structure for Multilevel Inverter with Minimum Power Electronic Components
Multi-level inverters (MLIs) are the best choice for medium and higher power applications. As the requirement of switches is more for higher levels, its cost and space are high in comparison with two-level inverters. A new structure for sub multi-level inverter (sub-MLI) is proposed with single source module and double source module to reduce power electronic components such as power switches, diodes, and drivers. The recommended cascaded structure is formed by connecting basic sub-MLI units in series to achieve minimum blocking voltage with less cost. In order to increase the voltage levels, the asymmetric topologies with different DC voltage values are also suggested. In addition, an optimal structure is arrived and compared with the conventional topologies to explore its advantages. It is found that the components, blocking voltage, and inverter cost are less. The proposed recommended cascaded structure is designed and analyzed for both symmetric and asymmetric configurations. The prototype is developed and performance of the inverter is experimentally verified for 13 and 31 level outputs.
- 9 August 2018
- Published by Taylor & Francis in Electric Power Components and Systems
- Vol. 46 (13) , 1432-1447
A Recommended Cascaded Structure for Multilevel Inverter with Minimum Power Electronic Components
Multi-level inverters (MLIs) are the best choice for medium and higher power applications. As the requirement of switches is more for higher levels, its cost and space are high in comparison with two-level inverters. A new structure for sub multi-level inverter (sub-MLI) is proposed with single source module and double source module to reduce power electronic components such as power switches, diodes, and drivers. The recommended cascaded structure is formed by connecting basic sub-MLI units in series to achieve minimum blocking voltage with less cost. In order to increase the voltage levels, the asymmetric topologies with different DC voltage values are also suggested. In addition, an optimal structure is arrived and compared with the conventional topologies to explore its advantages. It is found that the components, blocking voltage, and inverter cost are less. The proposed recommended cascaded structure is designed and analyzed for both symmetric and asymmetric configurations. The prototype is developed and performance of the inverter is experimentally verified for 13 and 31 level outputs.
- Open Access
- 1 June 2017
- Published by Elsevier in Energy Procedia
- Vol. 117, 855-861
Simulated Annealing Based Selective Harmonic Elimination for Multi-level Inverter
- 1 June 2017
- Published by Elsevier in Energy Procedia
- Vol. 117, 855-861
Open AccessSimulated Annealing Based Selective Harmonic Elimination for Multi-level Inverter
- 1 September 2016
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- Vol. 99, 157-162
Selective harmonic elimination: An comparative analysis for seven level inverter
Various control and modulation techniques such as Sine Pulse Width Modulation (SPWM), Space Vector modulation (SVM) and Selective Harmonic Elimination (SHE) have been used for multilevel inverter (MLI). The best method is SHE due to low switching losses and it suppress the specific unwanted harmonic. The various algorithms such as Genetic Algorithm (GA), bee algorithm, resultant theory and swarm intelligence have been applied by researchers. In this paper, a comparative analysis of SHE based seven levels inverter have been made using Particle Swarm Optimization (PSO), Simulated Annealing (SA), Bat Algorithm (BA) and Cuckoo Search Algorithm (CSA). The simulation has been done by MATLAB for seven level and the performance has been verified experimentally.
- 1 September 2016
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- Vol. 99, 157-162
Selective harmonic elimination: An comparative analysis for seven level inverter
Various control and modulation techniques such as Sine Pulse Width Modulation (SPWM), Space Vector modulation (SVM) and Selective Harmonic Elimination (SHE) have been used for multilevel inverter (MLI). The best method is SHE due to low switching losses and it suppress the specific unwanted harmonic. The various algorithms such as Genetic Algorithm (GA), bee algorithm, resultant theory and swarm intelligence have been applied by researchers. In this paper, a comparative analysis of SHE based seven levels inverter have been made using Particle Swarm Optimization (PSO), Simulated Annealing (SA), Bat Algorithm (BA) and Cuckoo Search Algorithm (CSA). The simulation has been done by MATLAB for seven level and the performance has been verified experimentally.
- 1 October 2015
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 42-47
Enhanced power quality of MLI using PSO based selective harmonic elimination
Multilevel inverter (MLI) has various advantages such as less EMI issues, voltage stress and switching losses, it is a best choice for industrial application. In tradition inverters, Harmonics can be eliminated by using large size of filters due to the lower order harmonics. This leads to increase the overall size, volume and cost of an inverter. But in MLI, the implementation of selective harmonic elimination (SHE) techniques eliminates lower order harmonics. In this work, the Particle Swarm Optimization algorithm (PSO) is applied to find the optimum switch angles which eliminates the lower order harmonics. PSO based optimization is applied for seven and nine level MLI. The simulation results are much closer with experimental result for seven and nine level inverter which provides better solution in comparison with existing algorithm.
- 1 October 2015
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 42-47
Enhanced power quality of MLI using PSO based selective harmonic elimination
Multilevel inverter (MLI) has various advantages such as less EMI issues, voltage stress and switching losses, it is a best choice for industrial application. In tradition inverters, Harmonics can be eliminated by using large size of filters due to the lower order harmonics. This leads to increase the overall size, volume and cost of an inverter. But in MLI, the implementation of selective harmonic elimination (SHE) techniques eliminates lower order harmonics. In this work, the Particle Swarm Optimization algorithm (PSO) is applied to find the optimum switch angles which eliminates the lower order harmonics. PSO based optimization is applied for seven and nine level MLI. The simulation results are much closer with experimental result for seven and nine level inverter which provides better solution in comparison with existing algorithm.
- 20 November 2014
- Published by Springer Nature
- p. 341-350
A Novel MLI Topology with Reduced Power Switches
- 20 November 2014
- Published by Springer Nature
- p. 341-350
A Novel MLI Topology with Reduced Power Switches
- 1 March 2014
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-6
Survey on smart grid technologies- smart metering, IoT and EMS
The application of communication and information technology in electrical utility makes consumers to be very comfortable. From the perspective of energy saving and power efficiency in Generation, Utility, Industry and homes an effective supervising of appliances is required. Now a day, smart grid conceptusing various cost effective communication technology and architecture proves electrical sector to have a bidirectional communication with utility and consumers as well as remote monitoring. Research and development in smart grid come up with new technology to make human life easier. This paper gives a strong idea about various technologies and standards for smart grid as well as smart metering /AMI. Also it provides knowledge on energy management system (EMS) and Internet of Things (IoT) for various applications.
- 1 March 2014
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-6
Survey on smart grid technologies- smart metering, IoT and EMS
The application of communication and information technology in electrical utility makes consumers to be very comfortable. From the perspective of energy saving and power efficiency in Generation, Utility, Industry and homes an effective supervising of appliances is required. Now a day, smart grid conceptusing various cost effective communication technology and architecture proves electrical sector to have a bidirectional communication with utility and consumers as well as remote monitoring. Research and development in smart grid come up with new technology to make human life easier. This paper gives a strong idea about various technologies and standards for smart grid as well as smart metering /AMI. Also it provides knowledge on energy management system (EMS) and Internet of Things (IoT) for various applications.