Jiann-Shiou Yang
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Jiann-Shiou Yang has a total of 4 co-authors. Here are the top co-authors by number of shared publications:
Aaron D. Vant
Member, IEEE, Department of Electrical and Computer Engineering, University of Minnesota, Duluth, MN 55812, USA
1 shared publicationDaniel Billings
Student Member, IEEE, Department of Electrical and Computer Engineering, University of Minnesota, Duluth, MN 55812, USA
1 shared publicationNicholas St. Jacque
Department of Electrical and Computer Engineering, University of Minnesota, Duluth, MN 55812, USA
1 shared publicationSamuel W. Rud
Member, IEEE, Department of Electrical and Computer Engineering, University of Minnesota, Duluth, MN 55812, USA
1 shared publication
Latest Publications
- 1 October 2006
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- Vol. 4 (1062922X) , 3503-3508
Non-Invasive Infrasound Heart Murmur Detection with a Support Vector Machine (SVM) Classification Approach
The goal of this paper is to present new devices and techniques that detect low frequency vibrations from the human chest and correlate them to cardiac conditions. Several new devices and techniques of detecting a human heart murmur have been developed through the extraction of vibrations primarily in the range of 10 -150 Hertz (Hz) on the human chest. The devices and techniques have been tested on different types of simulators and through clinical trials with the consent of the University of Minnesota Institutional Review Board (IRB). Signals were collected using a kardiac infrasound device (KID) and accelerometers integrated with a custom MATLAB software interface and a data acquisition system. Using the interface, the data was analyzed and classified by a support vector machine (SVM) approach. Results show that the SVM was able to classify signals under different testing environments. For clinical trials, the SVM distinguished between normal and abnormal cardiac conditions and between pathological and non-pathological cardiac conditions. Finally, using the various devices, a correlation between heart murmurs and normal hearts was observed from human chest vibrations.
- 1 October 2006
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- Vol. 4 (1062922X) , 3503-3508
Non-Invasive Infrasound Heart Murmur Detection with a Support Vector Machine (SVM) Classification Approach
The goal of this paper is to present new devices and techniques that detect low frequency vibrations from the human chest and correlate them to cardiac conditions. Several new devices and techniques of detecting a human heart murmur have been developed through the extraction of vibrations primarily in the range of 10 -150 Hertz (Hz) on the human chest. The devices and techniques have been tested on different types of simulators and through clinical trials with the consent of the University of Minnesota Institutional Review Board (IRB). Signals were collected using a kardiac infrasound device (KID) and accelerometers integrated with a custom MATLAB software interface and a data acquisition system. Using the interface, the data was analyzed and classified by a support vector machine (SVM) approach. Results show that the SVM was able to classify signals under different testing environments. For clinical trials, the SVM distinguished between normal and abnormal cardiac conditions and between pathological and non-pathological cardiac conditions. Finally, using the various devices, a correlation between heart murmurs and normal hearts was observed from human chest vibrations.
- 1 October 2006
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- Vol. 3 (1062922X) , 2529-2534
Application of the ARIMA Models to Urban Roadway Travel Time Prediction - A Case Study
Travel time is the time required to traverse a route between any two points of interest and it is an important parameter that can be used to measure the effectiveness of transportation systems. The ability to accurately predict freeway and arterial travel times in transportation networks is a critical component for many Intelligent Transportation Systems (ITS) applications. In this paper, we focus on the application of using time series models to study the arterial travel time prediction problem for urban roadways and a section of Minnesota State Highway 194 is chosen as our case study. We use the Global Positioning System (GPS) probe vehicle method to collect data. The time series modeling is then developed, in particular, we focus on the autoregressive integrated moving average (ARIMA) model due to the non-stationary property of the data collected. The section models established for the corridor are verified via both the residual analysis and portmanteau lack-of-fit test. Finally, based on the models developed we present our prediction results. Our study indicates the potential and effectiveness of using the ARIMA modeling in the prediction of travel time. The method presented in this paper can be easily modified and applied to short-term arterial travel time prediction for other urban areas.
- 1 October 2006
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- Vol. 3 (1062922X) , 2529-2534
Application of the ARIMA Models to Urban Roadway Travel Time Prediction - A Case Study
Travel time is the time required to traverse a route between any two points of interest and it is an important parameter that can be used to measure the effectiveness of transportation systems. The ability to accurately predict freeway and arterial travel times in transportation networks is a critical component for many Intelligent Transportation Systems (ITS) applications. In this paper, we focus on the application of using time series models to study the arterial travel time prediction problem for urban roadways and a section of Minnesota State Highway 194 is chosen as our case study. We use the Global Positioning System (GPS) probe vehicle method to collect data. The time series modeling is then developed, in particular, we focus on the autoregressive integrated moving average (ARIMA) model due to the non-stationary property of the data collected. The section models established for the corridor are verified via both the residual analysis and portmanteau lack-of-fit test. Finally, based on the models developed we present our prediction results. Our study indicates the potential and effectiveness of using the ARIMA modeling in the prediction of travel time. The method presented in this paper can be easily modified and applied to short-term arterial travel time prediction for other urban areas.