Mohammed E. Salem
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Mohammed E. Salem has a total of 5 co-authors. Here are the top co-authors by number of shared publications:
- Salina Abdul Samad
Department of Electrical, Electronics and Systems Engineering, Universiti Kebangsaan Malaysia, 43600Bangi, Malaysia
2 shared publications Azah Mohamed
IEEE Member
1 shared publication- Azah Mohamed
Universiti Kebangsaan Malaysia
1 shared publication - Iskandar Yahya
Lecturer at the Electrical, Electronic and Systems Engineering Department, Universiti Kebangsaan Malaysia
1 shared publication Oswald Jones
1 shared publication
Latest Publications
- 1 January 2007
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-5
Software Tool for Real Time Power Quality Disturbance Analysis and Classification
Real time detection and classification of power quality disturbances is important for quick diagnosis and mitigation of such disturbances. This paper presents the development of a software tool based on MatLab for power quality disturbance analysis and classification. Prior to the development of the software tool, the disturbance signals are captured and processed in real-time using the TMS320C6711DSP starter kit. Digital signal processor is used to provide fast data capture, fast data processing and signal processing flexibility with increased system performance and reduced system cost. The developed software tool can be used for real-time and off-line disturbance analysis by displaying the detected disturbance, % harmonics of a signal, total harmonic distortion and results of the S-transform, fast Fourier transform and continuous wavelet transform analyses. In addition, graphical representation of the input signal, power quality indices including sag and swell magnitudes are also displayed on the graphical user interface. PQ disturbance classification results show that accurate disturbance classification can be obtained with a total % of correct classification of 99.3%. Such a software tool can serve as a simple and reliable means for PQ disturbance detection and classification.
- 1 January 2007
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-5
Software Tool for Real Time Power Quality Disturbance Analysis and Classification
Real time detection and classification of power quality disturbances is important for quick diagnosis and mitigation of such disturbances. This paper presents the development of a software tool based on MatLab for power quality disturbance analysis and classification. Prior to the development of the software tool, the disturbance signals are captured and processed in real-time using the TMS320C6711DSP starter kit. Digital signal processor is used to provide fast data capture, fast data processing and signal processing flexibility with increased system performance and reduced system cost. The developed software tool can be used for real-time and off-line disturbance analysis by displaying the detected disturbance, % harmonics of a signal, total harmonic distortion and results of the S-transform, fast Fourier transform and continuous wavelet transform analyses. In addition, graphical representation of the input signal, power quality indices including sag and swell magnitudes are also displayed on the graphical user interface. PQ disturbance classification results show that accurate disturbance classification can be obtained with a total % of correct classification of 99.3%. Such a software tool can serve as a simple and reliable means for PQ disturbance detection and classification.
- 1 November 2006
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 94-98
DSP Implementation of Power Quality Disturbance Analysis Using Continuous Wavelet Transform
This paper presents a digital signal processor based prototype instrument to provide real-time analysis of power disturbances that can be used to perform quick power quality monitoring. The proposed instrument uses the Texas Instrument TMS320C6711DSP starter kit with a TIADS8364EVM 250-kHz, 16-bit, 6-channel and an analog digital converter mounted on the daughter card. For real-time analysis of power disturbances, the continuous wavelet transform is used to detect different types of disturbances such as voltage sag, swell, transient and harmonics. The results of analysis show that the implementation of continuous wavelet transform algorithm in DSP-based system provides accurate and fast detection of power quality disturbances.
- 1 November 2006
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 94-98
DSP Implementation of Power Quality Disturbance Analysis Using Continuous Wavelet Transform
This paper presents a digital signal processor based prototype instrument to provide real-time analysis of power disturbances that can be used to perform quick power quality monitoring. The proposed instrument uses the Texas Instrument TMS320C6711DSP starter kit with a TIADS8364EVM 250-kHz, 16-bit, 6-channel and an analog digital converter mounted on the daughter card. For real-time analysis of power disturbances, the continuous wavelet transform is used to detect different types of disturbances such as voltage sag, swell, transient and harmonics. The results of analysis show that the implementation of continuous wavelet transform algorithm in DSP-based system provides accurate and fast detection of power quality disturbances.