Ji-Hyun Kim
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Research Interests
Ji-Hyun Kim has a total of 10 co-authors. Here are the top co-authors by number of shared publications:
- Jae-Min Seo
Department of Prosthodontics, School of Dentistry, Jeonbuk National University, Jeonju, Republic of Korea
3 shared publications - Jung-Jin Lee
Department of Prosthodontics, School of Dentistry, Jeonbuk National University, Jeonju, Republic of Korea
3 shared publications - Tae-Sung Bae
Department of Dental Biomaterials, Institute of Biodegradable Materials, School of Dentistry, Jeonbuk National University, Jeonju, Korea
3 shared publications - Yeon-Hee Park
Department of Prosthodontics, School of Dentistry, Jeonbuk National University, Jeonju, Republic of Korea
3 shared publications - Min-Soo Bae
Department of Prosthodontics, School of Dentistry, Jeonbuk National University, Jeonju, Republic of Korea
2 shared publications - Jae-Hoon Park
Department of Prosthodontics, Institute of Oral Bio-Science, School of Dentistry, Jeonbuk National University and Research Institute of Clinical Medicine of Jeonbuk National University, Jeonju, Republic of Korea
1 shared publication
Latest Publications
- 8 October 2024
- Published by Springer Nature in Odontology
- Vol. 113 (2) , 645-654
Impact of liner treatment on the translucency of CAD/CAM multi-colored lithium disilicate and multi-layered zirconia implant-supported crowns, and evaluation of fracture strength of ceramic crowns
This study aimed to evaluate the optical properties of liner-treated CAD/CAM Multi-colored lithium disilicate (Amber Mill Direct; AMD) and multi-layered zirconia (Omega multi; OM) implant-supported crowns, as well as their effect on the fracture strength of Ti or Zr abutments to which they were applied. After sintering AMD and OM ceramic blocks, they were classified into three groups: untreated, liner-treated, and liner-treated with added color. Optical properties were evaluated by analyzing color differences using background materials to assess translucency and the masking ability of liner-treated ceramics. Subsequently, the fracture strength of implant-supported crowns applied to Ti or Zr abutments was measured, and statistical analysis was conducted using Weibull statistics. Untreated AMD exhibited the highest translucency. Liner treatment reduced translucency in both ceramics, while color-added liner treatment increased translucency. Liner-treated AMD showed greater color difference compared to OM, whereas color-added liner treatment reduced the color difference. Fracture strength was highest in Ti abutment-OM crowns (548.03 N) and lowest in Zr abutment-AMD crowns (283.58 N). Additionally, the Weibull coefficient was over twice as high in Ti abutment-AMD crowns (m = 17.500). Color liners can adjust the high translucency of lithium disilicate ceramics to block discoloration, providing natural tooth-like color and enabling the creation of esthetic restorations. Furthermore, lithium disilicate ceramic crowns applied to Ti abutments exhibited high Weibull coefficients and fracture strengths.
- 8 October 2024
- Published by Springer Nature in Odontology
- Vol. 113 (2) , 645-654
Impact of liner treatment on the translucency of CAD/CAM multi-colored lithium disilicate and multi-layered zirconia implant-supported crowns, and evaluation of fracture strength of ceramic crowns
This study aimed to evaluate the optical properties of liner-treated CAD/CAM Multi-colored lithium disilicate (Amber Mill Direct; AMD) and multi-layered zirconia (Omega multi; OM) implant-supported crowns, as well as their effect on the fracture strength of Ti or Zr abutments to which they were applied. After sintering AMD and OM ceramic blocks, they were classified into three groups: untreated, liner-treated, and liner-treated with added color. Optical properties were evaluated by analyzing color differences using background materials to assess translucency and the masking ability of liner-treated ceramics. Subsequently, the fracture strength of implant-supported crowns applied to Ti or Zr abutments was measured, and statistical analysis was conducted using Weibull statistics. Untreated AMD exhibited the highest translucency. Liner treatment reduced translucency in both ceramics, while color-added liner treatment increased translucency. Liner-treated AMD showed greater color difference compared to OM, whereas color-added liner treatment reduced the color difference. Fracture strength was highest in Ti abutment-OM crowns (548.03 N) and lowest in Zr abutment-AMD crowns (283.58 N). Additionally, the Weibull coefficient was over twice as high in Ti abutment-AMD crowns (m = 17.500). Color liners can adjust the high translucency of lithium disilicate ceramics to block discoloration, providing natural tooth-like color and enabling the creation of esthetic restorations. Furthermore, lithium disilicate ceramic crowns applied to Ti abutments exhibited high Weibull coefficients and fracture strengths.
- 30 June 2023
- Published by Korean Society for Dental Materials in Korean Journal of Dental Materials
- Vol. 50 (2) , 91-98
Aesthetic restoration using liner-treated lithium disilicate laminate veneers in discolored teeth after endodontic treatment : A case report
세라믹 재료의 기계적, 광학적 특성의 향상과 상아질 접착제의 발달로 심미성이 요구되는 전치부 수복 시 보다 성공적인 결과를 얻을 수 있게 되었다. 그 중 PLV (Porcelain Laminate Veneer)는 치아 삭제를 최소화하면서 보존적인 방식으로 심미적 개선을 이룰 수 있다. 20대 여성 환자가 상악 전치부의 심미적 개선을 위해 내원하였다. 환자의 주소는 외상 및 근관치료 후 발생한 지대치 변색이었고, 최소한의 치아 삭제를 원하는 환자의 요구를 반영하여 porcelain laminate veneer 수복을 결정하였다. PLV의 재료로는 높은 광투과성과 강도를 가지는 리튬 디실리케이트계 세라믹을 선택하였다. 더불어 수복물의 내면에 라이너를 처리하여, 자연 치아과 유사한 색조와 투과율을 갖는 본 소재의 심미적 특성을 유지하면서도 지대치의 변색을 효과적으로 차단하여 만족스러운 결과를 얻었기에 이를 보고하는 바이다.
- 30 June 2023
- Published by Korean Society for Dental Materials in Korean Journal of Dental Materials
- Vol. 50 (2) , 91-98
Aesthetic restoration using liner-treated lithium disilicate laminate veneers in discolored teeth after endodontic treatment : A case report
세라믹 재료의 기계적, 광학적 특성의 향상과 상아질 접착제의 발달로 심미성이 요구되는 전치부 수복 시 보다 성공적인 결과를 얻을 수 있게 되었다. 그 중 PLV (Porcelain Laminate Veneer)는 치아 삭제를 최소화하면서 보존적인 방식으로 심미적 개선을 이룰 수 있다. 20대 여성 환자가 상악 전치부의 심미적 개선을 위해 내원하였다. 환자의 주소는 외상 및 근관치료 후 발생한 지대치 변색이었고, 최소한의 치아 삭제를 원하는 환자의 요구를 반영하여 porcelain laminate veneer 수복을 결정하였다. PLV의 재료로는 높은 광투과성과 강도를 가지는 리튬 디실리케이트계 세라믹을 선택하였다. 더불어 수복물의 내면에 라이너를 처리하여, 자연 치아과 유사한 색조와 투과율을 갖는 본 소재의 심미적 특성을 유지하면서도 지대치의 변색을 효과적으로 차단하여 만족스러운 결과를 얻었기에 이를 보고하는 바이다.
- 30 June 2023
- Published by Korean Society for Dental Materials in Korean Journal of Dental Materials
- Vol. 50 (2) , 81-90
Aesthetic restoration of maxillary central incisor with discoloration using lithium disilicate treated with liner: A case report
최근 치과임상에서 도입되어 사용되고 있는 리튬디실리케이트 계의 다색 블록은 지르코니아계 블록으로 제작한 수복물에 비해 광투과성이 우수하여 전치부 수복에 적용시 심미적으로 양호한 결과를 얻을 수 있다. 또한 굴곡강도가 충분히 크고 레진 시멘트와 화학적 결합이 가능한 장점을 갖는다. 하지만 변색이 심한 지대치의 수복에 있어서는 높은 광투광성은 오히려 단점으로 작용할 수 있으며, 이를 보완하기 위해 다양한 방법들이 시도된 바 있다. 본 연구에서는 지대치 변색이 심한 중절치의 수복에서 리튬디실리케이트 계의 다색 블록으로 제작한 크라운의 내면을 라이너로 처리하여 하부의 색조를 차단함으로써 심미적으로 만족스러운 결과를 얻을 수 있었기에 보고하는 바이다.
- 30 June 2023
- Published by Korean Society for Dental Materials in Korean Journal of Dental Materials
- Vol. 50 (2) , 81-90
Aesthetic restoration of maxillary central incisor with discoloration using lithium disilicate treated with liner: A case report
최근 치과임상에서 도입되어 사용되고 있는 리튬디실리케이트 계의 다색 블록은 지르코니아계 블록으로 제작한 수복물에 비해 광투과성이 우수하여 전치부 수복에 적용시 심미적으로 양호한 결과를 얻을 수 있다. 또한 굴곡강도가 충분히 크고 레진 시멘트와 화학적 결합이 가능한 장점을 갖는다. 하지만 변색이 심한 지대치의 수복에 있어서는 높은 광투광성은 오히려 단점으로 작용할 수 있으며, 이를 보완하기 위해 다양한 방법들이 시도된 바 있다. 본 연구에서는 지대치 변색이 심한 중절치의 수복에서 리튬디실리케이트 계의 다색 블록으로 제작한 크라운의 내면을 라이너로 처리하여 하부의 색조를 차단함으로써 심미적으로 만족스러운 결과를 얻을 수 있었기에 보고하는 바이다.
- Open Access
- 1 January 2023
- Published by XMLink in The Journal of Korean Academy of Prosthodontics
- Vol. 61 (4) , 344-355
A comparative study of impression methods using stock tray and intraoral scanner in a completely edentulous patient with an atypical arch shape: a case report
박재훈, et al. J Korean Acad Prosthodont. 2023 Oct;61(4):344-355. https://doi.org/10.4047/jkap.2023.61.4.344
- 1 January 2023
- Published by XMLink in The Journal of Korean Academy of Prosthodontics
- Vol. 61 (4) , 344-355
Open AccessA comparative study of impression methods using stock tray and intraoral scanner in a completely edentulous patient with an atypical arch shape: a case report
박재훈, et al. J Korean Acad Prosthodont. 2023 Oct;61(4):344-355. https://doi.org/10.4047/jkap.2023.61.4.344