Max Reijman
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Max Reijman has a total of 29 co-authors. Here are the top co-authors by number of shared publications:
- Britt Barvelink
Department of Orthopedics and Sports Medicine, Erasmus University Medical Centre, Rotterdam, The Netherlands
2 shared publications - Joost W. Colaris
Department of Orthopaedics and Sports Medicine, Erasmus University Medical Center, Rotterdam, The Netherlands
2 shared publications - Andrew D. Duckworth
Edinburgh Orthopaedics, Royal Infirmary of Edinburgh, Edinburgh EH16 4SA, UK
1 shared publication Anne-Eva Bulstra
1 shared publication- Charlotte L. E. Laane
From the Division of Hand Surgery, Department of Orthopaedic Surgery, Massachusetts General Hospital, Boston, MA (Laane, Pratap, Cross, Shen, Chen, and Bhashyam), the Department of Surgery, Trauma Research Unit, University Medical Centre Rotterdam, Erasmus MC (Laane, and Wijffels), the Department of Statistics, Harvard University, Cambridge, MA (Pratap), and the Harvard Medical School, Boston, MA (Chen, and Bhashyam)
1 shared publication - Frank F. A. Ijpma
Department of Trauma Surgery, University Medical Center Groningen, University of Groningen, Groningen, Netherlands
1 shared publication
Latest Publications
- Open Access
- 17 January 2025
- Published by Springer Nature in European Journal of Trauma and Emergency Surgery
- Vol. 51 (1) , 1-8
An open source convolutional neural network to detect and localize distal radius fractures on plain radiographs
Purpose: Distal radius fractures (DRFs) are often initially assessed by junior doctors under time constraints, with limited supervision, risking significant consequences if missed. Convolutional Neural Networks (CNNs) can aid in diagnosing fractures. This study aims to internally and externally validate an open source algorithm for the detection and localization of DRFs. Methods: Patients from a level 1 trauma center from Adelaide, Australia that presented between 2016 and 2020 with wrist trauma were retrospectively included. Radiographs were reviewed confirming the presence or absence of a fracture, as well as annotating radius, ulna, and fracture location. An internal validation dataset from the same hospital was created. An external validation set was created with two other level 1 trauma centers, from Groningen and Rotterdam, the Netherlands. Three surgeons reviewed both sets for DRFs. Results: The algorithm was trained on 659 radiographs. The internal validation set included 190 patients, showing an accuracy of 87% and an AUC of 0.93 for DRF detection. The external validation set consisted of 188 patients, with an accuracy and AUC were 82% and 0.88 respectively. Radial and ulnar bone segmentation on the internal validation was excellent with an AP50 of 99 and 98, but moderate for fracture segmentation with an AP50 of 29. For external validation the AP50 was 92, 89 and 25 for radius, ulna, and fracture respectively. Conclusion: This open-source algorithm effectively detects DRFs with high accuracy and localizes them with moderate accuracy. It can assist clinicians in diagnosing suspected DRFs and is the first radiograph-based CNN externally validated on patients from multiple hospitals.
- 17 January 2025
- Published by Springer Nature in European Journal of Trauma and Emergency Surgery
- Vol. 51 (1) , 1-8
Open AccessAn open source convolutional neural network to detect and localize distal radius fractures on plain radiographs
Purpose: Distal radius fractures (DRFs) are often initially assessed by junior doctors under time constraints, with limited supervision, risking significant consequences if missed. Convolutional Neural Networks (CNNs) can aid in diagnosing fractures. This study aims to internally and externally validate an open source algorithm for the detection and localization of DRFs. Methods: Patients from a level 1 trauma center from Adelaide, Australia that presented between 2016 and 2020 with wrist trauma were retrospectively included. Radiographs were reviewed confirming the presence or absence of a fracture, as well as annotating radius, ulna, and fracture location. An internal validation dataset from the same hospital was created. An external validation set was created with two other level 1 trauma centers, from Groningen and Rotterdam, the Netherlands. Three surgeons reviewed both sets for DRFs. Results: The algorithm was trained on 659 radiographs. The internal validation set included 190 patients, showing an accuracy of 87% and an AUC of 0.93 for DRF detection. The external validation set consisted of 188 patients, with an accuracy and AUC were 82% and 0.88 respectively. Radial and ulnar bone segmentation on the internal validation was excellent with an AP50 of 99 and 98, but moderate for fracture segmentation with an AP50 of 29. For external validation the AP50 was 92, 89 and 25 for radius, ulna, and fracture respectively. Conclusion: This open-source algorithm effectively detects DRFs with high accuracy and localizes them with moderate accuracy. It can assist clinicians in diagnosing suspected DRFs and is the first radiograph-based CNN externally validated on patients from multiple hospitals.
- Open Access
- 1 July 2024
- Published by British Editorial Society of Bone & Joint Surgery in The Bone & Joint Journal
- Vol. 106-B (7) , 696-704
Redisplacement of reduced distal radius fractures in adults: does the type of casting play a role? The CAST study, a multicentre cluster randomized controlled trial
Aims: It is not clear which type of casting provides the best initial treatment in adults with a distal radial fracture. Given that between 32% and 64% of adequately reduced fractures redisplace during immobilization in a cast, preventing redisplacement and a disabling malunion or secondary surgery is an aim of treatment. In this study, we investigated whether circumferential casting leads to fewer the redisplacement of fewer fractures and better one-year outcomes compared with plaster splinting.Methods: In a pragmatic, open-label, multicentre, two-period cluster-randomized superiority trial, we compared these two types of casting. Recruitment took place in ten hospitals. Eligible patients aged ≥ 18 years with a displaced distal radial fracture, which was acceptably aligned after closed reduction, were included. The primary outcome measure was the rate of redisplacement within five weeks of immobilization. Secondary outcomes were the rate of complaints relating to the cast, clinical outcomes at three months, patient-reported outcome measures (PROMs) (using the numerical rating scale (NRS), the abbreviated version of the Disabilities of the Arm, Shoulder and Hand (QuickDASH), and Patient-Rated Wrist/Hand Evaluation (PRWHE) scores), and adverse events such as the development of compartment syndrome during one year of follow-up. We used multivariable mixed-effects logistic regression for the analysis of the primary outcome measure.Results: The study included 420 patients. There was no significant difference between the rate of redisplacement of the fracture between the groups: 47% (n = 88) for those treated with a plaster splint and 49% (n = 90) for those treated with a circumferential cast (odds ratio 1.05 (95% confidence interval (CI) 0.65 to 1.70); p = 0.854). Patients treated in a plaster splint reported significantly more pain than those treated with a circumferential cast, during the first week of treatment (estimated mean NRS 4.7 (95% CI 4.3 to 5.1) vs 4.1 (95% CI 3.7 to 4.4); p = 0.014). The rate of complaints relating to the cast, clinical outcomes and PROMs did not differ significantly between the groups (p > 0.05). Compartment syndrome did not occur.Conclusion: Circumferential casting did not result in a significantly different rate of redisplacement of the fracture compared with the use of a plaster splint. There were comparable outcomes in both groups.Cite this article: Bone Joint J 2024;106-B(7):696–704.
- 1 July 2024
- Published by British Editorial Society of Bone & Joint Surgery in The Bone & Joint Journal
- Vol. 106-B (7) , 696-704
Open AccessRedisplacement of reduced distal radius fractures in adults: does the type of casting play a role? The CAST study, a multicentre cluster randomized controlled trial
Aims: It is not clear which type of casting provides the best initial treatment in adults with a distal radial fracture. Given that between 32% and 64% of adequately reduced fractures redisplace during immobilization in a cast, preventing redisplacement and a disabling malunion or secondary surgery is an aim of treatment. In this study, we investigated whether circumferential casting leads to fewer the redisplacement of fewer fractures and better one-year outcomes compared with plaster splinting.Methods: In a pragmatic, open-label, multicentre, two-period cluster-randomized superiority trial, we compared these two types of casting. Recruitment took place in ten hospitals. Eligible patients aged ≥ 18 years with a displaced distal radial fracture, which was acceptably aligned after closed reduction, were included. The primary outcome measure was the rate of redisplacement within five weeks of immobilization. Secondary outcomes were the rate of complaints relating to the cast, clinical outcomes at three months, patient-reported outcome measures (PROMs) (using the numerical rating scale (NRS), the abbreviated version of the Disabilities of the Arm, Shoulder and Hand (QuickDASH), and Patient-Rated Wrist/Hand Evaluation (PRWHE) scores), and adverse events such as the development of compartment syndrome during one year of follow-up. We used multivariable mixed-effects logistic regression for the analysis of the primary outcome measure.Results: The study included 420 patients. There was no significant difference between the rate of redisplacement of the fracture between the groups: 47% (n = 88) for those treated with a plaster splint and 49% (n = 90) for those treated with a circumferential cast (odds ratio 1.05 (95% confidence interval (CI) 0.65 to 1.70); p = 0.854). Patients treated in a plaster splint reported significantly more pain than those treated with a circumferential cast, during the first week of treatment (estimated mean NRS 4.7 (95% CI 4.3 to 5.1) vs 4.1 (95% CI 3.7 to 4.4); p = 0.014). The rate of complaints relating to the cast, clinical outcomes and PROMs did not differ significantly between the groups (p > 0.05). Compartment syndrome did not occur.Conclusion: Circumferential casting did not result in a significantly different rate of redisplacement of the fracture compared with the use of a plaster splint. There were comparable outcomes in both groups.Cite this article: Bone Joint J 2024;106-B(7):696–704.
- 18 May 2016
- Published by Elsevier in The Journal of Arthroplasty
- Vol. 31 (10) , 2374
Letter to the Editor on "What Do Scottish Patients Expect of Their Total Knee Arthroplasty?".
- 18 May 2016
- Published by Elsevier in The Journal of Arthroplasty
- Vol. 31 (10) , 2374
Letter to the Editor on "What Do Scottish Patients Expect of Their Total Knee Arthroplasty?".