Mohamed Alaama
Mohamed Alaama has a total of 7 co-authors. Here are the top co-authors by number of shared publications:
Reem Saadi Khalid
3 shared publicationsAbdualrahman M. Abdualkader
Department of Pharmaceutical Chemistry Faculty of Pharmacy Analytical and Bio-Analytical Research Laboratory International Islamic University Malaysia (IIUM) Jalan Istana Bandar Indera Mahkota
2 shared publicationsAbdulrazak Kasmuri
Department of Pharmaceutical Chemistry Faculty of Pharmacy Analytical and Bio-Analytical Research Laboratory International Islamic University Malaysia (IIUM) Jalan Istana Bandar Indera Mahkota
2 shared publications- Abul Bashar Mohammed Helaluddin
Drug Discovery and Synthetic Chemistry Research Group, Department of Pharmaceutical Chemistry, Kulliyyah of Pharmacy, International Islamic University Malaysia (IIUM), Kuantan, Malaysia
2 shared publications Syed Atif Abbas
School of Pharmacy Taylors University 1 Jalan Taylor's Subang Jaya Selangor Darul Ehsan 47500 Malaysia
2 shared publicationsAbm Helal Uddin
Analytical and Bio Analytical Research Laboratory, Department of Pharmaceutical Chemistry, Faculty of Pharmacy, International Islamic University Malaysia (IIUM), Kuantan, Malaysia
1 shared publication
Latest Publications
- Open Access
- 5 October 2016
- Published by African Journals Online (AJOL) in Tropical Journal of Pharmaceutical Research
- Vol. 15 (9) , 1967
Reliability of graphite furnace atomic absorption spectrometry as alternative method for trace analysis of arsenic in natural medicinal products
Purpose: To evaluate the comparative efficiency of graphite furnace atomic absorption spectrometry (GFAAS) and hydride generation atomic absorption spectrometry (HGAAS) for trace analysis of arsenic (As) in natural herbal products (NHPs). Method: Arsenic analysis in natural herbal products and standard reference material was conducted using atomic absorption spectrometry (AAS), namely, hydride generation ASSAAS (HGAAS) and graphite furnace (GFAAS). The samples were digested with HNO3–H2O2 in a ratio of 4:1 using microwave-assisted acid digestion. The methods were validated with the aid of the standard reference material 1515 Apple Leaves (SRM) from NIST Results: Mean recovery of three different samples of NHPs, using HGAAS and GFAAS, ranged from 89.3 - 91.4 %, and 91.7 - 93.0 %, respectively. The difference between the two methods was insignificant. A (P= 0.5), B (P=0.4) and C (P=0.88) Relative standard deviation (RSD) RSD, i.e., precision was 2.5 - 6.5 % and 2.3 - 6.7 % using HGAAS and GFAAS techniques, respectively. Recovery of arsenic in SRM was 98 and 102 % by GFAAS and HGAAS, respectively. Conclusion: GFAAS demonstrates acceptable levels of precision and accuracy. Both techniques possess comparable accuracy and repeatability. Thus, the two methods are recommended as an alternative approach for trace analysis of arsenic in natural herbal products. Keywords: Arsenic, Graphite furnace atomic absorption spectrometer (GFAAS), Hydride generation atomic absorption spectrometer (HGAAS), Natural herbal products
- 5 October 2016
- Published by African Journals Online (AJOL) in Tropical Journal of Pharmaceutical Research
- Vol. 15 (9) , 1967
Open AccessReliability of graphite furnace atomic absorption spectrometry as alternative method for trace analysis of arsenic in natural medicinal products
Purpose: To evaluate the comparative efficiency of graphite furnace atomic absorption spectrometry (GFAAS) and hydride generation atomic absorption spectrometry (HGAAS) for trace analysis of arsenic (As) in natural herbal products (NHPs). Method: Arsenic analysis in natural herbal products and standard reference material was conducted using atomic absorption spectrometry (AAS), namely, hydride generation ASSAAS (HGAAS) and graphite furnace (GFAAS). The samples were digested with HNO3–H2O2 in a ratio of 4:1 using microwave-assisted acid digestion. The methods were validated with the aid of the standard reference material 1515 Apple Leaves (SRM) from NIST Results: Mean recovery of three different samples of NHPs, using HGAAS and GFAAS, ranged from 89.3 - 91.4 %, and 91.7 - 93.0 %, respectively. The difference between the two methods was insignificant. A (P= 0.5), B (P=0.4) and C (P=0.88) Relative standard deviation (RSD) RSD, i.e., precision was 2.5 - 6.5 % and 2.3 - 6.7 % using HGAAS and GFAAS techniques, respectively. Recovery of arsenic in SRM was 98 and 102 % by GFAAS and HGAAS, respectively. Conclusion: GFAAS demonstrates acceptable levels of precision and accuracy. Both techniques possess comparable accuracy and repeatability. Thus, the two methods are recommended as an alternative approach for trace analysis of arsenic in natural herbal products. Keywords: Arsenic, Graphite furnace atomic absorption spectrometer (GFAAS), Hydride generation atomic absorption spectrometer (HGAAS), Natural herbal products
- Open Access
- 4 March 2016
- Published by African Journals Online (AJOL) in Tropical Journal of Pharmaceutical Research
- Vol. 15 (2) , 427
Main Analytical Techniques Used for Elemental Analysis in Various Matrices
Main Analytical Techniques Used for Elemental Analysis in Various Matrices
- 4 March 2016
- Published by African Journals Online (AJOL) in Tropical Journal of Pharmaceutical Research
- Vol. 15 (2) , 427
Open AccessMain Analytical Techniques Used for Elemental Analysis in Various Matrices
Main Analytical Techniques Used for Elemental Analysis in Various Matrices
- Top Cited PapersOpen Access
- 30 January 2016
- Published by Springer Nature in Journal of Analytical Science and Technology
- Vol. 7 (1) , 1-7
Comparative study of three digestion methods for elemental analysis in traditional medicine products using atomic absorption spectrometry
- 30 January 2016
- Published by Springer Nature in Journal of Analytical Science and Technology
- Vol. 7 (1) , 1-7
Top Cited PapersOpen AccessComparative study of three digestion methods for elemental analysis in traditional medicine products using atomic absorption spectrometry