SDShengbao Duan

Shengbao Duan

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Shengbao Duan has a total of 44 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Marked platelet transfusion refractoriness caused by anti-HLA-I and anti-HPA-5b antibodies: A case report

    by Yihan Wang, Zhen Liu, Shengbao Duan, Chunyan Lin, Yiming Jin, Hongmei Wang, Yujue Wang, Longhai Tang, Mingyuan Wang

    Rationale: Platelet transfusions are the key treatment for patients with severely low platelet counts and significant bleeding symptoms. Platelet transfusion refractorines (PTR) is defined as unsatisfactory transfusion of platelets with at least 2 ABO blood groups matched and stored for <72 hours. Patient concerns: A 37-year-old woman presented for medical evaluation due to the cessation of fetal heart activity after 50 days of gestation. Diagnoses: AML-M2, PTR. Interventions: To explore potential immune-mediated causes of platelet refractoriness, the following diagnostic evaluations were conducted: Platelet antibody screening using the PAK-Lx assay (Immucor) to detect anti-HLA class I and HPA antibodies. Anti-HLA class I specificity determination via LIFECODES LSA Single Antigen bead assays (Luminex). Molecular typing of HLA class I and HPA alleles using PCR-sequence based typing (PCR-SBT), as well as CD36 phenotyping via flow cytometry. Confirmation testing for anti-HPA-5b antibodies using chloroquine-treated platelet solid-phase assays. Outcomes: The patient had high-fluorescence-intensity HLA antibodies along with HPA antibodies, resulting in severe refractoriness to platelet transfusion. Lessons: Various methods were used to comprehensively analyze the specificity of anti-platelet antibodies in the samples of patients with ineffective platelet transfusion, thus providing a reference for the clinical diagnosis and treatment of PTR.

  • Open Access

    A novel colorimetric immunosensor based on silk cocoon membrane-integrated ELISA for treponemal antibody detection

    by Hongmei Wang, Yizhi Huang, Qi Xiao, Yezhou Chen, Yujue Wang, Jingjing Tian, Yuqing Cai, Longhai Tang, Shaohua Ding, Shengbao Duan

    The global rise in syphilis incidence and the challenges of early diagnosis highlight the urgent need for convenient diagnostic tools. In this study, we present a colorimetric immunosensor for the detection of Treponema pallidum antibodies (TP-Ab) using a natural silk cocoon membrane (SCM) as the substrate, based on the principle of enzyme-linked immunosorbent assay (ELISA). The TP monoclonal antibody 3H12 and the chimera antigen TP99, comprising epitopes TP15, TP17, and TP47, were sequentially coupled to functionalized SCM to form the SCM-based TP-Ab immunosensor. The detection was quantified by color extraction, and the Corrected I red values were used as a judgment parameter. The TP-Ab immunosensor demonstrated a detection limit of 0.48 mIU/mL, lower than the 0.68 mIU/mL limit of commercial microplate ELISA kits. Furthermore, it exhibited no cross-reactivity with antibodies against other pathogens. Testing with a reference serum panel yielded 100% concordance with the reference results. Comprehensive statistical analysis of the Corrected I red values from the reference serum panel and banked samples indicated an optimal cutoff value of 0.0921, achieving 100% sensitivity, 97.96% specificity, and high overall accuracy, with an area under the curve of 0.9995 and a 95% confidence interval of 0.9979–1.00. Moreover, a statistically significant correlation with microplate ELISA was observed ( r = 0.9217, P < 0.0001). This reliable ELISA-integrated colorimetric immunosensor, featuring a three-dimensional porous structure and inherent bioactivity, contributes to improving the detection performance and provides a rapid and convenient diagnostic solution for syphilis. It is particularly well-suited for resource-limited settings where on-site testing is critical. IMPORTANCE: Syphilis remains a major global public health concern, particularly in resource-limited settings where early and accurate diagnosis is often hindered by technical and economic barriers. Here, we report a novel treponemal antibody (TP-Ab) immunosensor based on natural silk cocoon membrane (SCM), a biocompatible and porous material with intrinsic bioactivity. By integrating enzyme-linked immunosorbent assay principles and a recombinant TP15-17-47 chimera antigen, the SCM-based immunosensor enables colorimetric detection of TP-Ab with high specificity and visual readout. Unlike traditional methods that require complex instrumentation or expensive reagents, this platform offers a low-cost, portable, and easy-to-use alternative suitable for on-site or point-of-care testing. The findings highlight the potential of silk-derived biosensors in a promising direction for syphilis screening technologies.


  • Open Access

    CircRNA ZFR promotes cell progression by regulating miR-96a-5p/SLC1A1 axis in hepatocellular carcinoma

    by Christian Cedric Bongolo, Yu Zhang, ShengBao Duan, Louise Virginie Mounoume Lobe, Erick Thokerunga, Peter Kisembo, HongMei Wang, ShaoHua Ding, JingJing Tian, YeZhou Chen, et al.

    Research has identified the dysregulation of circular RNA ZFR (circRNA ZFR) as a key factor in hepatocellular carcinoma (HCC) progression, though its precise molecular mechanisms remain unclear. This study assessed circRNA ZFR expression in clinical samples and HCC cells using qRT-PCR and Fluorescent In Situ Hybridization assays. Cell functions were evaluated through colony formation, transwell, and wound healing assays. circRNA ZFR and miR-96a-5p interaction was investigated using luciferase reporter assays and qRT-PCR, while miR-96a-5p and SLC1A1 interaction was examined using luciferase reporter assays, western blot analysis, and Chromatin Isolation by RNA Purification/Mass Spectrometry (CHIRP/MS). CircRNA ZFR was significantly upregulated in blood, tissue samples and HCC cells compared to their respective normal controls (P < 0.001), and were associated with tumor differentiation (r = 0.249, p = 0.031), tumor size (r = 0.258, p = 0.027) and tumor-node-metastasis (TNM) stage (r = 0.287, p = 0.020). CircRNA ZFR overexpression promoted HCC cell proliferation, migration and invasion while its knockdown inhibited HCC progression. miR-96a-5p was identified as the putative target for CircRNA ZFR and its inhibition promoted HCC through modulating the expression of SLC1A1 gene. Collectively, circRNA ZFR knockdown retarded HCC progression by sponging miR-96a-5p and modulating SLC1A1 expression, suggesting that the circZFR/miR-96a-5p/SLC1A1 axis may serve as potential therapeutic targets for HCC.


  • Open Access

    Scalability and application of silk fiber paper as a natural-based matrix for immunosensing

    by Shaohua Ding, Hongmei Wang, Yezhou Chen, Jingjing Tian, Feiran Wu, Yujue Wang, Zebin Hu, Shengbao Duan


  • Analysis of cluster of differentiation 36 expression and genetic variation in blood donors in Zhongshan City, China

    by Ainong Sun, Yujue Wang, Yonglun Wu, Feng Ge, Xin Ye, Hongmei Wang, Yezhou Chen, Shaohua Ding, Jingjing Tian, Qiao Li, et al.

    OBJECTIVE: Individuals with a cluster of differentiation 36 (CD36) deficiency are at risk of developing anti-CD36 antibodies after platelet transfusion or pregnancy. Therefore, we investigated CD36 expression on platelets of blood donors in Zhongshan city, and analyzed the frequency of CD36 deficiency and gene polymorphism. METHODS: A total of 846 healthy donors were randomly selected. CD36 expression on platelets was tested and monocytes from CD36-negative samples were further analyzed to determine the type of CD36 deficiency through flow cytometry. Genetic variation was analyzed through genomic DNA sequencing of exons 3–14 in the protein-coding region of CD36. Anti-CD36 antibody detection for the donors with CD36 deficiency was performed. RESULTS: The frequency of CD36-negative platelets in blood donors was 1.77% (15/846), of which Type I deficiency accounted for 0.12% (1/846) and Type II accounted for 1.65% (14/846). Seven types of gene mutations in eight cases of CD36-negative samples were discovered: 329_330 del AC (n = 2), 287 G > C (n = 1), 220 C > T and 1228_1239 ATTGTGCCTATT (n = 1), 1228_1239 ATTGTGCCTATT (n = 1), 538 T > C and 879 T > C (n = 1), 287 G > C and 1163 A > T (n = 1), and 429 + 3 dup G (n = 1). Moreover, the anti-CD36 antibody was detected in the plasma of donors with Type I CD36 deficiency. CONCLUSION: A new mutation site in exon 5 (429 + 3 dup G) was identified. The establishment of a CD36-negative database can provide compatible platelets to improve the efficacy of transfusion.

  • Open Access

    High-Throughput CD36 Phenotyping on Human Platelets Based on Sandwich ELISA and Mutant Gene Analysis

    by Honghong He, Longhai Tang, Yiming Jin, Yujue Wang, Hongmei Wang, Shaohua Ding, Yezhou Chen, Jingjing Tian, Mingyuan Wang, Shengbao Duan

    Background: CD36 deficiency is closely associated with fetal/neonatal alloimmune thrombocytopenia, platelet transfusion refractoriness, and other hemorrhage disorders, particularly in Asian and African populations. There is a clinical need for rapid and high-throughput methods of platelet CD36 (pCD36) phenotyping to improve the availability of CD36 typing of donors and assist clinical blood transfusions for patients with anti-CD36 antibodies. Such methods can also support the establishment of databases of pCD36-negative phenotypes. Study Design and Methods: A sandwich enzyme-linked immunosorbent assay (ELISA) for CD36 phenotyping of human platelets was developed using anti-CD36 monoclonal antibodies. The reliability of the assay was evaluated by calculating the intra-assay and inter-assay coefficients of variation (CV). A total of 1,691 anticoagulant whole blood samples from healthy blood donors were randomly selected. PCD36 expression was measured using a sandwich ELISA. PCD36 deficiency was confirmed by flow cytometry (FC). Mutations underlying pCD36 deficiency were identified using polymerase chain reaction sequence-based typing (PCR-SBT). Results: The sandwich ELISA for pCD36 phenotyping had high reliability (intra-assay CV, 2.1–4.8%; inter-assay CV, 2.3–5.2%). The sandwich ELISA was used to screen for CD36 expression on platelets isolated from 1,691 healthy blood donors. Of these, 36 samples were pCD36-negative. FC demonstrated absence of CD36 expression on monocytes in three of the 36 cases. In the present study population, the frequency of CD36 deficiency was 2.13% (36/1,691), of which 0.18% (3/1,691) was type I deficiency and 1.95% (33/1,691) was type II deficiency. In addition, we used PCR-SBT to characterize the gene mutations in exons 3–14 of the CD36 gene in 27 cases of CD36 deficiency and discovered 10 types of mutations in 13 pCD36-negative samples. Conclusion: The present study describes the development and characterization of a highly reliable sandwich ELISA for high-throughput screening for pCD36 expression. This novel method is feasible for clinical applications and provides a useful tool for the establishment of databases of pCD36-negative phenotype donors.


  • A CNN-LASSO ensemble classification model for incomplete antibody reactants screening in coombs test

    by Keqing Wu, Hongmei Wang, Yujue Wang, Shengbao Duan, Xin Gao

    BACKGROUND: Precise classification of incomplete antibody reactants (IAR) in the Coombs test is the primary means to prevent incompatible blood transfusions. Currently, an automatic and contactless method is required for accurate IAR classification to avoid human error. OBJECTIVE: We present an ensemble learning algorithm that integrates five convolutional neural networks and the least absolute shrinkage and selection operator (LASSO) regression algorithm into an IAR intensity classification model. METHODS: A dataset including 1628 IAR and corresponding labels of IAR intensity categories ((-), (1+), (2+), (3+), and (4+)) was used. We trained the ensemble model using 1302 IAR and validated its performance using 326 IAR. The optimal ensemble model was used to assist immunologists in classifying IAR. The chord diagrams based on the human-machine interaction were established. RESULTS: The ensemble model achieved 98.8%, 98.4%, 99.7%, 99.5%, and 99.4% accuracies in the (-), (1+), (2+), (3+), and (4+) categories, respectively. The results were compared with those of manual classification by immunologists (average accuracy: 99.2% vs. 75.6%). Using the model, all three immunologists achieved increased accuracy (average accuracy: +8.4%). CONCLUSIONS: The proposed algorithm can thus effectively improve the accuracy and efficiency of IAR intensity classification and facilitate the automation of haemolytic disease screening equipment.