Hemanth Kumar Karaka
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Hemanth Kumar Karaka has a total of 3 co-authors. Here are the top co-authors by number of shared publications:
Rajesh Kumar Tripathi
Department of Civil Engineering, National Institute of Technology Raipur, Raipur, India
3 shared publications- Rajesh Kumar Tripathi
Department of Civil Engineering, National Institute of Technology Raipur, Raipur, India
3 shared publications R.K. Tripathi
Department of Civil Engineering, Professor, National Institute of Technology, Raipur, 492010, India
1 shared publication
Latest Publications
- 1 December 2023
- Published by Springer Nature in Bulletin of Earthquake Engineering
- Vol. 22 (3) , 1387-1423
Damage assessment of infilled frame structures using applied element method
- 1 December 2023
- Published by Springer Nature in Bulletin of Earthquake Engineering
- Vol. 22 (3) , 1387-1423
Damage assessment of infilled frame structures using applied element method
- 31 October 2023
- Published by Springer Nature in Innovative Infrastructure Solutions
- Vol. 8 (11) , 1-25
Assessing potential damage and energy dissipation in low-rise high-strength concrete frames with strong infill walls using applied element method
- 31 October 2023
- Published by Springer Nature in Innovative Infrastructure Solutions
- Vol. 8 (11) , 1-25
Assessing potential damage and energy dissipation in low-rise high-strength concrete frames with strong infill walls using applied element method
- 4 August 2023
- Published by Springer Nature in Asian Journal of Civil Engineering
- Vol. 25 (2) , 1225-1239
Numerical modeling of weak infills with a central opening in high-strength concrete frames under pseudo-static loading using applied element method
- 4 August 2023
- Published by Springer Nature in Asian Journal of Civil Engineering
- Vol. 25 (2) , 1225-1239
Numerical modeling of weak infills with a central opening in high-strength concrete frames under pseudo-static loading using applied element method
- Open Access
- 25 July 2023
- Published by Springer Nature in Research Square
Damage assessment of High Strength Reinforced Concrete Frames subjected to Cyclic Displacement-controlled Loading Condition using Applied Element Method
When building structures are subjected to extreme loads, such as earthquakes, explosions, crane loads, natural calamities, etc., both the structural and non-structural components suffer significant damage. It is necessary to determine the magnitude of these damages and required to improve upcoming designs and take additional action for the damaged structures. High Strength Concrete (HSC) frames generally have smaller cross-sections of members with high strength and stiffness than Normal Strength Concrete (NSC), with non-structural components like masonry walls playing a crucial part. Masonry walls significantly further increase the stiffness and strength of these slender structures. But because of their brittle nature, structural and non-structural elements abruptly fail under heavy loading circumstances, causing further casualties. Numerous computational techniques, including FEM, XFEM, and DEM, were used better to understand the crack location of RC-framed infill masonry walls. However, these techniques could not identify adistinct damage pattern under extreme operating conditions. The Applied Element Method (AEM) has recently become a powerful numerical tool with acceptable accuracy and processing time for monitoring the development of structural cracks. This study uses AEM to analyse the damage patterns based on displacement-controlled in-plane cyclic loads on single- and multi-storey reinforced concrete frames with and without infill walls. The investigation concluded that the infilled frame has better in-plane lateral load resistance than the bare frame. The multi-storey soft-storey frame resisted a higher load than the multi-storey infilled frame because the slender HSC frames with strong infill induced rapid shear failure at the beam-column connection of the first floor. HSC structures are constantly challenged by the need for a robust infill wall to increase the stiffness of the frames. The AEM results showed that it provided a trustworthy endorsement of the experimental and theoretical findings.
- 25 July 2023
- Published by Springer Nature in Research Square
Open AccessDamage assessment of High Strength Reinforced Concrete Frames subjected to Cyclic Displacement-controlled Loading Condition using Applied Element Method
When building structures are subjected to extreme loads, such as earthquakes, explosions, crane loads, natural calamities, etc., both the structural and non-structural components suffer significant damage. It is necessary to determine the magnitude of these damages and required to improve upcoming designs and take additional action for the damaged structures. High Strength Concrete (HSC) frames generally have smaller cross-sections of members with high strength and stiffness than Normal Strength Concrete (NSC), with non-structural components like masonry walls playing a crucial part. Masonry walls significantly further increase the stiffness and strength of these slender structures. But because of their brittle nature, structural and non-structural elements abruptly fail under heavy loading circumstances, causing further casualties. Numerous computational techniques, including FEM, XFEM, and DEM, were used better to understand the crack location of RC-framed infill masonry walls. However, these techniques could not identify adistinct damage pattern under extreme operating conditions. The Applied Element Method (AEM) has recently become a powerful numerical tool with acceptable accuracy and processing time for monitoring the development of structural cracks. This study uses AEM to analyse the damage patterns based on displacement-controlled in-plane cyclic loads on single- and multi-storey reinforced concrete frames with and without infill walls. The investigation concluded that the infilled frame has better in-plane lateral load resistance than the bare frame. The multi-storey soft-storey frame resisted a higher load than the multi-storey infilled frame because the slender HSC frames with strong infill induced rapid shear failure at the beam-column connection of the first floor. HSC structures are constantly challenged by the need for a robust infill wall to increase the stiffness of the frames. The AEM results showed that it provided a trustworthy endorsement of the experimental and theoretical findings.
- Open Access
- 20 July 2023
- Published by Springer Nature in Research Square
Numerical modelling of weak infills with a central opening in high-strength concrete frames under pseudo-static loading using Applied Element Method
High-strength concrete (HSC) is widely used in developed countries for reinforced concrete structures due to benefits like lower concrete usage, smaller columns, increased floor area, and economic advantages. HSC reduces deflections and offers a high elastic modulus and low creep deformations, making it valuable in seismic-prone areas by decreasing inertial loads and lateral drift. However, the lack of new Concrete Standards for HSC challenges structural engineers. Infill walls are essential for separating interior spaces, particularly in seismic regions where weak infill within a strong frame dissipates energy and reduces lateral displacements. Nonetheless, weak infill behaves more brittle under intense seismic loads, posing risks like falling debris and causing casualties. Openings in infill walls are necessary for practical, architectural, or aesthetic reasons, but their strength and stiffness contributions are often neglected in current design practices. Infill walls significantly alter a building's seismic response compared to a bare frame, while frequent openings reduce the infilled frame's lateral stiffness and strength. A micro-modelling study using the Applied Element Method (AEM) examines the role of brick masonry infill with various sizes and positions of openings. Ten single-story, single-bay infilled frames with different percentages of openings undergo displacement-controlled cyclic loading. The lateral load capacities, displacements, and energy dissipation are compared for high-strength concrete frames with openings. Results showed that weak infill-strong frames with and without openings altered lateral load resistance, and severe failure was observed on either side of the central opening. The vertical position and shape of the openings also influence the studied parameters.
- 20 July 2023
- Published by Springer Nature in Research Square
Open AccessNumerical modelling of weak infills with a central opening in high-strength concrete frames under pseudo-static loading using Applied Element Method
High-strength concrete (HSC) is widely used in developed countries for reinforced concrete structures due to benefits like lower concrete usage, smaller columns, increased floor area, and economic advantages. HSC reduces deflections and offers a high elastic modulus and low creep deformations, making it valuable in seismic-prone areas by decreasing inertial loads and lateral drift. However, the lack of new Concrete Standards for HSC challenges structural engineers. Infill walls are essential for separating interior spaces, particularly in seismic regions where weak infill within a strong frame dissipates energy and reduces lateral displacements. Nonetheless, weak infill behaves more brittle under intense seismic loads, posing risks like falling debris and causing casualties. Openings in infill walls are necessary for practical, architectural, or aesthetic reasons, but their strength and stiffness contributions are often neglected in current design practices. Infill walls significantly alter a building's seismic response compared to a bare frame, while frequent openings reduce the infilled frame's lateral stiffness and strength. A micro-modelling study using the Applied Element Method (AEM) examines the role of brick masonry infill with various sizes and positions of openings. Ten single-story, single-bay infilled frames with different percentages of openings undergo displacement-controlled cyclic loading. The lateral load capacities, displacements, and energy dissipation are compared for high-strength concrete frames with openings. Results showed that weak infill-strong frames with and without openings altered lateral load resistance, and severe failure was observed on either side of the central opening. The vertical position and shape of the openings also influence the studied parameters.
- Open Access
- 19 December 2022
- Published by Alwaha Scientific Publishing Services SARL in Asps Conference Proceedings
- Vol. 1 (1) , 625-630
Effect of Vertical Setbacks of Space Frame Structure under Seismic and Blast Loads using Applied Element Method
Structures, when subjected to nonlinear dynamic loading, drastically affect the structure’s physical properties. The structural failure occurred at the critical points of weakness during the earthquake. These structural weaknesses observed in irregular structures are mainly due to the improper distribution of mass, geometry and stiffness. Architects usually prefer irregular buildings for the aesthetics point of view. These irregular structures are more vulnerable to dynamic loading. On the other hand, the devastating failure due to bomb blast is also the concern for the study as many vital structures collapsed because of the terrorist attack. Such failures need to be checked by studying the performance of building under the earthquake and blast loading. The objectives of this paper are to compare the peak responses at each storey level of mass irregular space frame structure to the dynamic effect. Firstly, Time History of the Northridge earthquake spectra with Peak Ground Acceleration (P.G.A.) =8.660 m/s2 = 0.883g at 9.82 seconds considered and analysed. Secondly, blast material [1] composed of two different charge weights [2] 1000 kg TNT and 2500 kg TNT at a distance of 10m was considered. For responses to the structure, the most advanced numerical tool viz., Applied Element Method (AEM) has been used. It is concluded that the amplitude of Northridge earthquake’s maximum x-displacement at the terrace level is closer to maximum x-displacement for the blast load of 2500kg TNT but the time of occurrence was changed abruptly, i.e., Northridge earthquake maximum displacement occurs at the duration of nearly 10 sec, but the maximum displacement of blast load of 2500kg TNT is occurring almost at 0.2 sec, i.e., 50 times quicker in occurrence.
- 19 December 2022
- Published by Alwaha Scientific Publishing Services SARL in Asps Conference Proceedings
- Vol. 1 (1) , 625-630
Open AccessEffect of Vertical Setbacks of Space Frame Structure under Seismic and Blast Loads using Applied Element Method
Structures, when subjected to nonlinear dynamic loading, drastically affect the structure’s physical properties. The structural failure occurred at the critical points of weakness during the earthquake. These structural weaknesses observed in irregular structures are mainly due to the improper distribution of mass, geometry and stiffness. Architects usually prefer irregular buildings for the aesthetics point of view. These irregular structures are more vulnerable to dynamic loading. On the other hand, the devastating failure due to bomb blast is also the concern for the study as many vital structures collapsed because of the terrorist attack. Such failures need to be checked by studying the performance of building under the earthquake and blast loading. The objectives of this paper are to compare the peak responses at each storey level of mass irregular space frame structure to the dynamic effect. Firstly, Time History of the Northridge earthquake spectra with Peak Ground Acceleration (P.G.A.) =8.660 m/s2 = 0.883g at 9.82 seconds considered and analysed. Secondly, blast material [1] composed of two different charge weights [2] 1000 kg TNT and 2500 kg TNT at a distance of 10m was considered. For responses to the structure, the most advanced numerical tool viz., Applied Element Method (AEM) has been used. It is concluded that the amplitude of Northridge earthquake’s maximum x-displacement at the terrace level is closer to maximum x-displacement for the blast load of 2500kg TNT but the time of occurrence was changed abruptly, i.e., Northridge earthquake maximum displacement occurs at the duration of nearly 10 sec, but the maximum displacement of blast load of 2500kg TNT is occurring almost at 0.2 sec, i.e., 50 times quicker in occurrence.
- 4 September 2021
- Published by Springer Nature
- p. 941-953
Performance Evaluation of Masonry Infill Walls in Reinforced Concrete Frames Under Cyclic Loading Using Applied Element Method
- 4 September 2021
- Published by Springer Nature
- p. 941-953
Performance Evaluation of Masonry Infill Walls in Reinforced Concrete Frames Under Cyclic Loading Using Applied Element Method