George A. Richards
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
George A. Richards has a total of 7 co-authors. Here are the top co-authors by number of shared publications:
- Jared Ramsey
Allegheny Orthopedic Associates, Pittsburgh, PA 15241, USA
2 shared publications - Jeffrey D. Buxton
Department of Exercise Science, Grove City College, Grove City, PA 16127, USA
2 shared publications - Kelly J. Shields
Data Science R&D, Highmark Health, Pittsburgh, PA 15222, USA
2 shared publications - Christopher Adams
School of Osteopathic Medicine, Campbell University, Lillington, NC 27546, USA
1 shared publication - Christopher Adams
Department of Pediatrics, Pediatric Resident, Akron Children’s Hospital, Akron, OH 44308, USA
1 shared publication - Holyna Nhean
EnGen, Highmark Health, Pittsburgh, PA 15222, USA
1 shared publication
Latest Publications
- Open Access
- 23 January 2025
- Published by MDPI AG in Biomechanics
- Vol. 5 (1) , 7
Investigation of Acoustic Signals for Gait Analysis
Background: Previous literature has demonstrated that footstep sounds can be related to the unique gait pattern of individuals. This paper investigates the potential of using footstep sounds as a diagnostic tool in gait analysis. Methods: Fifteen participants ran on a treadmill at 2.7 m/s (6.0 MPH) while simultaneously recording plantar pressure and acoustic signals. Participants repeated the same recordings after completing an exhaustive fatigue protocol, thereby creating a modified gait pattern. Results: The modified gait was evident in the center-of-force trajectory, contact pressures, and acoustic signatures. Analysis of the peak contact pressure and acoustic amplitude showed a modest, statistically significant correlation (r = 0.42, p = 0.02). A method to measure the gait stance time from features in the acoustic signature was tested. Conclusions: The results show that acoustic signals can be used to characterize gait changes, but additional work is needed to link acoustic signal features to gait events like toe lift.
- 23 January 2025
- Published by MDPI AG in Biomechanics
- Vol. 5 (1) , 7
Open AccessInvestigation of Acoustic Signals for Gait Analysis
Background: Previous literature has demonstrated that footstep sounds can be related to the unique gait pattern of individuals. This paper investigates the potential of using footstep sounds as a diagnostic tool in gait analysis. Methods: Fifteen participants ran on a treadmill at 2.7 m/s (6.0 MPH) while simultaneously recording plantar pressure and acoustic signals. Participants repeated the same recordings after completing an exhaustive fatigue protocol, thereby creating a modified gait pattern. Results: The modified gait was evident in the center-of-force trajectory, contact pressures, and acoustic signatures. Analysis of the peak contact pressure and acoustic amplitude showed a modest, statistically significant correlation (r = 0.42, p = 0.02). A method to measure the gait stance time from features in the acoustic signature was tested. Conclusions: The results show that acoustic signals can be used to characterize gait changes, but additional work is needed to link acoustic signal features to gait events like toe lift.
- Open Access
- 23 July 2023
- Published by MDPI AG in Biomechanics
- Vol. 3 (3) , 310-321
Fatigue Effects on Peak Plantar Pressure and Bilateral Symmetry during Gait at Various Speeds
Fatigue-related changes in gait biomechanics, specifically plantar pressures, are well documented in the general population. However, research is generally confined to unilateral measures across a limited range of speeds, while changes in more well-trained populations remain largely unknown. Therefore, we sought to assess the impact of fatigue on bilateral peak plantar pressure (PP) and plantar pressure symmetry angle (SA) in well-trained runners across a range of speeds. Data from 16 (females, n = 9) well-trained runners were collected using in-sole pressure sensors pre- and post-fatigue at the following speeds: walking (1.3 m/s), jogging (2.7 m/s), running (3.3 m/s), and sprinting (4.5 m/s). Pre-fatigue PP significantly increased from walking to jogging (p < 0.001) and from jogging to running (p < 0.005) with no difference between running and sprinting (p > 0.05). Post-fatigue PP for walking was less than jogging (p < 0.002), running (p < 0.001), and sprinting (p < 0.001), with no other significant differences (p > 0.05). Post-fatigue PP was significantly greater when compared to pre-fatigue PP at all speeds (p < 0.001 for all). Though SA was not significantly different pre- to post-fatigue across speeds (p’s > 0.05) at the cohort level, noteworthy changes were observed at the individual level. Overall, fatigue effects are present at all running speeds but isolating these effects to a single side (left or right) may be inadequate.
- 23 July 2023
- Published by MDPI AG in Biomechanics
- Vol. 3 (3) , 310-321
Open AccessFatigue Effects on Peak Plantar Pressure and Bilateral Symmetry during Gait at Various Speeds
Fatigue-related changes in gait biomechanics, specifically plantar pressures, are well documented in the general population. However, research is generally confined to unilateral measures across a limited range of speeds, while changes in more well-trained populations remain largely unknown. Therefore, we sought to assess the impact of fatigue on bilateral peak plantar pressure (PP) and plantar pressure symmetry angle (SA) in well-trained runners across a range of speeds. Data from 16 (females, n = 9) well-trained runners were collected using in-sole pressure sensors pre- and post-fatigue at the following speeds: walking (1.3 m/s), jogging (2.7 m/s), running (3.3 m/s), and sprinting (4.5 m/s). Pre-fatigue PP significantly increased from walking to jogging (p < 0.001) and from jogging to running (p < 0.005) with no difference between running and sprinting (p > 0.05). Post-fatigue PP for walking was less than jogging (p < 0.002), running (p < 0.001), and sprinting (p < 0.001), with no other significant differences (p > 0.05). Post-fatigue PP was significantly greater when compared to pre-fatigue PP at all speeds (p < 0.001 for all). Though SA was not significantly different pre- to post-fatigue across speeds (p’s > 0.05) at the cohort level, noteworthy changes were observed at the individual level. Overall, fatigue effects are present at all running speeds but isolating these effects to a single side (left or right) may be inadequate.