Benjamin Neumann
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Benjamin Neumann has a total of 12 co-authors. Here are the top co-authors by number of shared publications:
- Arja Suzanne Vink
Department of Cardiology, Amsterdam University Medical Center, University of Amsterdam, 1105 AZ Amsterdam, The Netherlands
1 shared publication - Arthur Arnold Maria Wilde
ERN GUARD‐Heart Amsterdam the Netherlands
1 shared publication - Ben J. M. Hermans
Department of Cardiology, Cardiovascular Research Institute Maastricht (CARIM), Maastricht University Medical Center+ , P. Debyelaan 25, Maastricht 6229 HX
1 shared publication Britt-Maria Beckmann
Department of Medicine I, LMU University Hospital, LMU Munich , Munich , Germany
1 shared publication- Didem Cömert
Department of Clinical and Experimental Cardiology, Amsterdam UMC, University of Amsterdam, Heart Center , Amsterdam , The Netherlands
1 shared publication - Krystien V. V. Lieve
AMC Heart Center, Department of Clinical and Experimental Cardiology, Academic Medical Center, Amsterdam, the Netherlands
1 shared publication
Latest Publications
- Open Access
- 20 July 2023
- Published by Oxford University Press (OUP) in EP Europace
- Vol. 25 (9)
Manual vs. automatic assessment of the QT-interval and corrected QT
Aims: Sudden cardiac death (SCD) is challenging to predict. Electrocardiogram (ECG)-derived heart rate-corrected QT-interval (QTc) is used for SCD-risk assessment. QTc is preferably determined manually, but vendor-provided automatic results from ECG recorders are convenient. Agreement between manual and automatic assessments is unclear for populations with aberrant QTc. We aimed to systematically assess pairwise agreement of automatic and manual QT-intervals and QTc. Methods and results: A multi-centre cohort enriching aberrant QTc comprised ECGs of healthy controls and long-QT syndrome (LQTS) patients. Manual QT-intervals and QTc were determined by the tangent and threshold methods and compared to automatically generated, vendor-provided values. We assessed agreement globally by intra-class correlation coefficients and pairwise by Bland–Altman analyses and 95% limits of agreement (LoA). Further, manual results were compared to a novel automatic QT-interval algorithm. ECGs of 1263 participants (720 LQTS patients; 543 controls) were available [median age 34 (inter-quartile range 35) years, 55% women]. Comparing cohort means, automatic and manual QT-intervals and QTc were similar. However, pairwise Bland–Altman-based agreement was highly discrepant. For QT-interval, LoAs spanned 95 (tangent) and 92 ms (threshold), respectively. For QTc, the spread was 108 and 105 ms, respectively. LQTS patients exhibited more pronounced differences. For automatic QTc results from 440–540 ms (tangent) and 430–530 ms (threshold), misassessment risk was highest. Novel automatic QT-interval algorithms may narrow this range. Conclusion: Pairwise vendor-provided automatic and manual QT-interval and QTc results can be highly discrepant. Novel automatic algorithms may improve agreement. Within the above ranges, automatic QT-interval and QTc results require manual confirmation, particularly if T-wave morphology is challenging.
- 20 July 2023
- Published by Oxford University Press (OUP) in EP Europace
- Vol. 25 (9)
Open AccessManual vs. automatic assessment of the QT-interval and corrected QT
Aims: Sudden cardiac death (SCD) is challenging to predict. Electrocardiogram (ECG)-derived heart rate-corrected QT-interval (QTc) is used for SCD-risk assessment. QTc is preferably determined manually, but vendor-provided automatic results from ECG recorders are convenient. Agreement between manual and automatic assessments is unclear for populations with aberrant QTc. We aimed to systematically assess pairwise agreement of automatic and manual QT-intervals and QTc. Methods and results: A multi-centre cohort enriching aberrant QTc comprised ECGs of healthy controls and long-QT syndrome (LQTS) patients. Manual QT-intervals and QTc were determined by the tangent and threshold methods and compared to automatically generated, vendor-provided values. We assessed agreement globally by intra-class correlation coefficients and pairwise by Bland–Altman analyses and 95% limits of agreement (LoA). Further, manual results were compared to a novel automatic QT-interval algorithm. ECGs of 1263 participants (720 LQTS patients; 543 controls) were available [median age 34 (inter-quartile range 35) years, 55% women]. Comparing cohort means, automatic and manual QT-intervals and QTc were similar. However, pairwise Bland–Altman-based agreement was highly discrepant. For QT-interval, LoAs spanned 95 (tangent) and 92 ms (threshold), respectively. For QTc, the spread was 108 and 105 ms, respectively. LQTS patients exhibited more pronounced differences. For automatic QTc results from 440–540 ms (tangent) and 430–530 ms (threshold), misassessment risk was highest. Novel automatic QT-interval algorithms may narrow this range. Conclusion: Pairwise vendor-provided automatic and manual QT-interval and QTc results can be highly discrepant. Novel automatic algorithms may improve agreement. Within the above ranges, automatic QT-interval and QTc results require manual confirmation, particularly if T-wave morphology is challenging.