Jinsheng Lai
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Jinsheng Lai has a total of 11 co-authors. Here are the top co-authors by number of shared publications:
- Chen Chen
Division of Cardiology, Department of Internal Medicine, Tongji Hospital, Tongji Medical College, Huazhong University of Science and Technology, Wuhan, China
3 shared publications Guoran Ruan
Division of Cardiology and Hubei Key Laboratory of Genetics and Molecular Mechanisms of Cardiological Disorders, Tongji Hospital, Tongji Medical College, Huazhong University of Science and Technology, Wuhan, China
3 shared publicationsJin Wang
Division of Cardiology and Hubei Key Laboratory of Genetics and Molecular Mechanisms of Cardiological Disorders, Tongji Hospital, Tongji Medical College, Huazhong University of Science and Technology, Wuhan, China
3 shared publicationsLijian Ding
School of Electrical Engineering and Automation, Hefei University of Technology, Hefei, China
3 shared publicationsMengying He
Division of Cardiology and Hubei Key Laboratory of Genetics and Molecular Mechanisms of Cardiological Disorders, Tongji Hospital, Tongji Medical College, Huazhong University of Science and Technology, Wuhan, China
3 shared publicationsXingfa Liu
State Key Laboratory of Power Grid Environmental Protection, High Voltage Research Institute, China Electric Power Research Institute, Wuhan, China
3 shared publications
Latest Publications
- 27 October 2020
- Published by Taylor & Francis in Electromagnetic Biology and Medicine
- Vol. 40 (1) , 138-149
The effects of extremely low frequency electromagnetic fields exposure at 1 mT on hemogram and blood biochemisgtry in rats
The biological effects of extremely low-frequency electromagnetic fields (ELF-EMF) exposure are not fully clarified. We conducted this investigation to explore the effects of ELF-EMF on hematologic and biochemical indexes in adult rats. Thirty adult male Sprague-Dawley rats were exposed to ELF-EMF at 1 mT for 24 weeks, while another 30 SD rats were sham exposed. During the exposure, peripheral blood was collected every 4 weeks to analyze the hematologic parameters and biochemical indexes. The morphology of liver and kidney was detected by hematoxylin-eosin staining at the end of the experiment. Exposed to ELF-EMF at 1 mT did not exert any statistic difference on hematologic parameters including total white blood cell count, neutrophil ratio, lymphocyte ratio, red blood cells, hemoglobin concentration and platelets count, compared to the control group. Similarly, biochemical indexes, such as glucose, lipid profile, liver function and renal function, were not affected by ELF-EMF exposure. In addition, no morphological change was observed in the liver and kidney from the exposure group. The exposure to ELF-EMF at the intensity of 1 mT for 24 weeks did not affect hematologic and biochemical indexes in adult rats.
- 27 October 2020
- Published by Taylor & Francis in Electromagnetic Biology and Medicine
- Vol. 40 (1) , 138-149
The effects of extremely low frequency electromagnetic fields exposure at 1 mT on hemogram and blood biochemisgtry in rats
The biological effects of extremely low-frequency electromagnetic fields (ELF-EMF) exposure are not fully clarified. We conducted this investigation to explore the effects of ELF-EMF on hematologic and biochemical indexes in adult rats. Thirty adult male Sprague-Dawley rats were exposed to ELF-EMF at 1 mT for 24 weeks, while another 30 SD rats were sham exposed. During the exposure, peripheral blood was collected every 4 weeks to analyze the hematologic parameters and biochemical indexes. The morphology of liver and kidney was detected by hematoxylin-eosin staining at the end of the experiment. Exposed to ELF-EMF at 1 mT did not exert any statistic difference on hematologic parameters including total white blood cell count, neutrophil ratio, lymphocyte ratio, red blood cells, hemoglobin concentration and platelets count, compared to the control group. Similarly, biochemical indexes, such as glucose, lipid profile, liver function and renal function, were not affected by ELF-EMF exposure. In addition, no morphological change was observed in the liver and kidney from the exposure group. The exposure to ELF-EMF at the intensity of 1 mT for 24 weeks did not affect hematologic and biochemical indexes in adult rats.
- 25 August 2020
- Published by Wiley in Bioelectromagnetics
- Vol. 41 (7) , 511-525
An Investigation Into the Effects of Long‐Term 50‐Hz Power‐Frequency Electromagnetic Field Exposure on Hematogram, Blood Chemistry, Fibrosis, and Oxidant Stress Status in the Liver and the Kidney From Sprague–Dawley Rats
Power‐frequency electromagnetic fields (PF‐EMFs) at 50 Hz are potential health risk factors. This study aimed to explore the effects of long‐term exposure to 50‐Hz PF‐EMFs on general physiological conditions in Sprague–Dawley (SD) rats. During a 24‐week exposure period, the body mass and water and food intake of the animals were recorded regularly. The hematologic parameters were detected every 12 weeks, and blood chemistry analyses were performed every 4 weeks. After sacrifice, morphology was identified by hematoxylin–eosin, Masson, and immunohistochemical staining. Fibrosis‐related gene expression and oxidative stress status were also detected. Compared with the control group, exposure to 30, 100, or 500 μT PF‐EMF did not exert any effect on body mass, food intake, or water intake. Similarly, no significant differences were found in hematologic parameters or blood chemistry analyses among these groups. Furthermore, morphological assays showed that exposure to PF‐EMFs had no influence on the structure of the liver or kidney. Finally, fibrosis‐related gene expression and oxidative stress status were unaltered by PF‐EMF exposure. The present study indicates that 24 weeks of exposure to PF‐EMFs at intensities of 30, 100, or 500 μT might not affect hemograms, blood chemistry, fibrosis, or oxidative stress in the liver or kidney in SD rats. © 2020 Bioelectromagnetics Society
- 25 August 2020
- Published by Wiley in Bioelectromagnetics
- Vol. 41 (7) , 511-525
An Investigation Into the Effects of Long‐Term 50‐Hz Power‐Frequency Electromagnetic Field Exposure on Hematogram, Blood Chemistry, Fibrosis, and Oxidant Stress Status in the Liver and the Kidney From Sprague–Dawley Rats
Power‐frequency electromagnetic fields (PF‐EMFs) at 50 Hz are potential health risk factors. This study aimed to explore the effects of long‐term exposure to 50‐Hz PF‐EMFs on general physiological conditions in Sprague–Dawley (SD) rats. During a 24‐week exposure period, the body mass and water and food intake of the animals were recorded regularly. The hematologic parameters were detected every 12 weeks, and blood chemistry analyses were performed every 4 weeks. After sacrifice, morphology was identified by hematoxylin–eosin, Masson, and immunohistochemical staining. Fibrosis‐related gene expression and oxidative stress status were also detected. Compared with the control group, exposure to 30, 100, or 500 μT PF‐EMF did not exert any effect on body mass, food intake, or water intake. Similarly, no significant differences were found in hematologic parameters or blood chemistry analyses among these groups. Furthermore, morphological assays showed that exposure to PF‐EMFs had no influence on the structure of the liver or kidney. Finally, fibrosis‐related gene expression and oxidative stress status were unaltered by PF‐EMF exposure. The present study indicates that 24 weeks of exposure to PF‐EMFs at intensities of 30, 100, or 500 μT might not affect hemograms, blood chemistry, fibrosis, or oxidative stress in the liver or kidney in SD rats. © 2020 Bioelectromagnetics Society
- Open Access
- 7 April 2020
- Published by Frontiers Media SA in Frontiers in Public Health
- Vol. 8, 87
Examination of the Effect of a 50-Hz Electromagnetic Field at 500 μT on Parameters Related With the Cardiovascular System in Rats
Background: Whether electromagnetic field (EMF) exposure affects the function of the cardiovascular system is under debate. The present study aimed to investigate the effects of 500 μT EMF exposure on the cardiovascular system in rats. Methods: Forty-eight-week-old male Sprague-Dawley rats were randomly divided into two groups: the sham group and the exposure group. During 24-week EMF exposure (20 h per day), the blood pressure and pulse rate were recorded every 4 weeks. Before sacrifice, electrocardiography, echocardiography, and cardiac catheterization analysis were conducted to evaluate the cardiac function. Meanwhile, hematoxylin-eosin (HE) staining, Western blot, and real-time polymerase chain reaction (PCR) were performed to identify morphological and molecular changes indicative of cardiac remodeling. Results: The heart rate, blood pressure, and pulse rate were not influenced by EMF exposure compared with the control group. In addition, HE staining showed no change in the morphology and arrangement of cardiomyocytes. Further, we found that the mRNA and protein levels of cardiac hypertrophy-related genes were not affected by EMF exposure. Finally, no significant difference was observed in cardiac function between the two groups by echocardiography and cardiac catheterization detection. Conclusion: The 24-week exposure to EMF at 500 μT did not have apparent effects on the cardiovascular system in rats, at least for the variables studied.
- 7 April 2020
- Published by Frontiers Media SA in Frontiers in Public Health
- Vol. 8, 87
Open AccessExamination of the Effect of a 50-Hz Electromagnetic Field at 500 μT on Parameters Related With the Cardiovascular System in Rats
Background: Whether electromagnetic field (EMF) exposure affects the function of the cardiovascular system is under debate. The present study aimed to investigate the effects of 500 μT EMF exposure on the cardiovascular system in rats. Methods: Forty-eight-week-old male Sprague-Dawley rats were randomly divided into two groups: the sham group and the exposure group. During 24-week EMF exposure (20 h per day), the blood pressure and pulse rate were recorded every 4 weeks. Before sacrifice, electrocardiography, echocardiography, and cardiac catheterization analysis were conducted to evaluate the cardiac function. Meanwhile, hematoxylin-eosin (HE) staining, Western blot, and real-time polymerase chain reaction (PCR) were performed to identify morphological and molecular changes indicative of cardiac remodeling. Results: The heart rate, blood pressure, and pulse rate were not influenced by EMF exposure compared with the control group. In addition, HE staining showed no change in the morphology and arrangement of cardiomyocytes. Further, we found that the mRNA and protein levels of cardiac hypertrophy-related genes were not affected by EMF exposure. Finally, no significant difference was observed in cardiac function between the two groups by echocardiography and cardiac catheterization detection. Conclusion: The 24-week exposure to EMF at 500 μT did not have apparent effects on the cardiovascular system in rats, at least for the variables studied.