Kiagus Aufa Ibrahim
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Kiagus Aufa Ibrahim has a total of 27 co-authors. Here are the top co-authors by number of shared publications:
- Masahiro Takei
Graduate School of Engineering, Chiba University
7 shared publications Hiroshi Fujimoto
Department of General Surgery, Graduate School of Medicine, Chiba University, Chiba, Japan
3 shared publicationsHiroto Yamamoto
Department of General Surgery, Graduate School of Medicine, Chiba University, Chiba, Japan
3 shared publications- Prima Asmara Sejati
Universitas Gadjah Mada
3 shared publications - Galih Setyawan
Department of Electrical Engineering and Informatics, Vocational College, Universitas Gadjah Mada, Yogyakarta., Indonesia
2 shared publications - Marlin Ramadhan Baidillah
Research Center for Electronics, National Research and Innovation Agency, KST Samaun Samadikun, Bandung 40135, Indonesia
2 shared publications
Latest Publications
- 17 June 2026
- Published by IOP Publishing in Measurement Science and Technology
- Vol. 37 (25) , 255701
Sodium-ion concentration imaging within dermis layer by planar electrical impedance tomography implementing gamma-Jacobian matrix ( γ J-pEIT)
Sodium-ion (Na + ) accumulation in the dermis has been increasingly recognized as a functional biomarker associated with various pathological conditions. Non-invasive and accessible methods for localized assessment remain limited. A planar electrical impedance tomography (pEIT) implementing gamma-Jacobian matrix ( γ J -pEIT ) has been proposed to image the sodium-ion concentration c Na within dermis layer. The gamma-Jacobian matrix γ J establishes a relationship between conductivity distribution σ and the peaks of deconvolved reactance γ ^ associated with c Na within the dermis layer. The γ J integrates frequency-dependent features derived from deconvolved reactance γ into Jacobian matrix formulation to enhance sensitivity to dermis-associated electrical responses. The γ J -pEIT is applied for c Na imaging within dermis layer in both simulation and ex-vivo experiments across a range of c Na from 5 to 50 mM . As results, the γ J shows broader spatial sensitivity and higher dermis-related sensitivity than the Typ J , with 33.8 and 19.32 times increases in the standard deviation ς and mean absolute dermis-related sensitivity | de J m | , respectively. Overall, the γ J -pEIT demonstrates enhanced sensitivity and reliable accuracy in visualizing c Na within the dermis layer. In simulation, the γ J -pEIT accurately reconstructed conductivity changes γ sim Δσ across the various c Na within the dermis layer with a strong agreement ( R = 0.982 ) . The γ J provides an 18-fold increase in sensitivity to c Na relative to Typ J . Experimental results further demonstrate a strong relationship ( R = 0.997 ) between c Na and ⟨ Δ σ ⟩ . These results demonstrate the potential of the proposed γ J -pEIT for functional imaging of sodium-related processes in the dermis, providing a promising pathway towards non-invasive assessment of tissue ionic microenvironments.
- 17 June 2026
- Published by IOP Publishing in Measurement Science and Technology
- Vol. 37 (25) , 255701
Sodium-ion concentration imaging within dermis layer by planar electrical impedance tomography implementing gamma-Jacobian matrix ( γ J-pEIT)
Sodium-ion (Na + ) accumulation in the dermis has been increasingly recognized as a functional biomarker associated with various pathological conditions. Non-invasive and accessible methods for localized assessment remain limited. A planar electrical impedance tomography (pEIT) implementing gamma-Jacobian matrix ( γ J -pEIT ) has been proposed to image the sodium-ion concentration c Na within dermis layer. The gamma-Jacobian matrix γ J establishes a relationship between conductivity distribution σ and the peaks of deconvolved reactance γ ^ associated with c Na within the dermis layer. The γ J integrates frequency-dependent features derived from deconvolved reactance γ into Jacobian matrix formulation to enhance sensitivity to dermis-associated electrical responses. The γ J -pEIT is applied for c Na imaging within dermis layer in both simulation and ex-vivo experiments across a range of c Na from 5 to 50 mM . As results, the γ J shows broader spatial sensitivity and higher dermis-related sensitivity than the Typ J , with 33.8 and 19.32 times increases in the standard deviation ς and mean absolute dermis-related sensitivity | de J m | , respectively. Overall, the γ J -pEIT demonstrates enhanced sensitivity and reliable accuracy in visualizing c Na within the dermis layer. In simulation, the γ J -pEIT accurately reconstructed conductivity changes γ sim Δσ across the various c Na within the dermis layer with a strong agreement ( R = 0.982 ) . The γ J provides an 18-fold increase in sensitivity to c Na relative to Typ J . Experimental results further demonstrate a strong relationship ( R = 0.997 ) between c Na and ⟨ Δ σ ⟩ . These results demonstrate the potential of the proposed γ J -pEIT for functional imaging of sodium-related processes in the dermis, providing a promising pathway towards non-invasive assessment of tissue ionic microenvironments.
- 11 May 2026
- Published by IOP Publishing in Measurement Science and Technology
- Vol. 37 (25)
Area clustering of breast cancer tissues by electrical impedance tomography implemented with poisson and gaussian mixture models (EIT-PGMM)
Area of breast cancer tissues has been clustered by newly-proposed electrical impedance tomography (EIT) implemented with Poisson and Gaussian mixture models (EIT-PGMM) for breast cancer identification. EIT-PGMM comprises two distinct methods for comparison: EIT-PMM (Poisson Mixture Model) and EIT-GMM (Gaussian Mixture Model). EIT-PGMM consists of two sections which are 1) reconstruction section by EIT to reconstruct conductivity distribution σ ∈R ( F × N ) ( f : frequency 1≤ f ≤ F , n : area resolution 1≤ n ≤ N ) from impedance distribution Z ∈C ( F × M ) ( f : frequency 1≤ f ≤ F , m : measurement number 1≤ m ≤ M ) on injection current i between electrodes on measurement boundary and measurement voltages v , and 2) clustering section by PGMM to cluster breast cancer area B with cluster assignment (one-hot vector) s ∈R ( N × K ) ( k : cluster number 1≤ k ≤ K ) to sharpen the border between cancerous and normal breast tissues. The s is probabilistically determined through posterior p ( s|σ,Θ ) ( Θ : parameters of Poisson and Gaussian mixture models) assigns each spatial resolution to a specific cluster, which highest mean conductivity distribution 〈 σ k 〉 among the K clusters is identified as the breast cancer region B . The EIT-PGMM was applied to the mastectomized breast tissues from 5 patients placed inside hemispherical sensor of EIT under the condition of injection current frequencies f ranging from 1 [kHz] to 3 [MHz]. Qualitatively, breast cancer region B remains similar across different values of K and between EIT-PMM and EIT-GMM. In order to quantitatively evaluate B , the results of EIT-PMM and EIT-GMM were compared with the diameter D measured clinically and area A of breast cancer segmented from the coronal plane of CT scan. EIT-GMM provides a more accurate estimation of breast cancer region B with accuracy of 90.2% in diameter D K GMM . and 79.3% in area A K GMM .
- 11 May 2026
- Published by IOP Publishing in Measurement Science and Technology
- Vol. 37 (25)
Area clustering of breast cancer tissues by electrical impedance tomography implemented with poisson and gaussian mixture models (EIT-PGMM)
Area of breast cancer tissues has been clustered by newly-proposed electrical impedance tomography (EIT) implemented with Poisson and Gaussian mixture models (EIT-PGMM) for breast cancer identification. EIT-PGMM comprises two distinct methods for comparison: EIT-PMM (Poisson Mixture Model) and EIT-GMM (Gaussian Mixture Model). EIT-PGMM consists of two sections which are 1) reconstruction section by EIT to reconstruct conductivity distribution σ ∈R ( F × N ) ( f : frequency 1≤ f ≤ F , n : area resolution 1≤ n ≤ N ) from impedance distribution Z ∈C ( F × M ) ( f : frequency 1≤ f ≤ F , m : measurement number 1≤ m ≤ M ) on injection current i between electrodes on measurement boundary and measurement voltages v , and 2) clustering section by PGMM to cluster breast cancer area B with cluster assignment (one-hot vector) s ∈R ( N × K ) ( k : cluster number 1≤ k ≤ K ) to sharpen the border between cancerous and normal breast tissues. The s is probabilistically determined through posterior p ( s|σ,Θ ) ( Θ : parameters of Poisson and Gaussian mixture models) assigns each spatial resolution to a specific cluster, which highest mean conductivity distribution 〈 σ k 〉 among the K clusters is identified as the breast cancer region B . The EIT-PGMM was applied to the mastectomized breast tissues from 5 patients placed inside hemispherical sensor of EIT under the condition of injection current frequencies f ranging from 1 [kHz] to 3 [MHz]. Qualitatively, breast cancer region B remains similar across different values of K and between EIT-PMM and EIT-GMM. In order to quantitatively evaluate B , the results of EIT-PMM and EIT-GMM were compared with the diameter D measured clinically and area A of breast cancer segmented from the coronal plane of CT scan. EIT-GMM provides a more accurate estimation of breast cancer region B with accuracy of 90.2% in diameter D K GMM . and 79.3% in area A K GMM .
- Open Access
- 22 January 2026
- Published by Springer Nature in Annals of Biomedical Engineering
- Vol. 54 (6) , 1709-1722
Conductive Response Imaging in Thigh Muscle Compartments by Electrical Impedance Tomography for Efficient Bicycle Training Strategy
The conductive response in thigh muscle compartments has been imaged by electrical impedance tomography (EIT) under bicycle-operation conditions and muscle-stimulation conditions to determine an efficient training strategy. EIT is already applied to evaluate the effectiveness of electrical muscle stimulation (EMS) on human muscle, and hybrid of EMS which combines EMS on biceps and voluntary resistance training simultaneously. In this study, we newly applied EIT to the thigh muscle compartments and imaged the conductive response under bicycle-operation conditions and muscle-stimulation conditions. The bicycle-operation conditions are high pedal rate in low torque (HPLT) and low pedal rate in high torque (LPHT). The muscle-stimulation conditions are bicycle condition and EMS-combined bicycle condition. As a result, EIT successfully imaged the conductive response in three muscle compartments which are T1 compartment (quadriceps), T2 compartment (hamstrings), and T3 compartment (other than the quadriceps and hamstrings). The spatial-mean conductivity changes $$\Delta \langle {{\varvec{\sigma}}}_{{\varvec{P}}}\rangle$$ (the power of bicycle training $${\varvec{P}}=103,152,\mathbf{o}\mathbf{r}194[\mathbf{W}]$$ ) increased with increasing power $${\varvec{P}}$$ of the bicycle training across all four conditions and in all muscle compartments ( $${\varvec{\beta}}=0.531,\boldsymbol{ }{\varvec{p}}<0.001$$ ). The $$\Delta \langle {{\varvec{\sigma}}}_{{\varvec{P}}}\rangle$$ of HPLT tended to be larger than $$\Delta \langle {{\varvec{\sigma}}}_{{\varvec{P}}}\rangle$$ of LPHT ( $${\varvec{\beta}}=-35.52,\boldsymbol{ }{\varvec{p}}<0.001$$ ). The $$\Delta \langle {{\varvec{\sigma}}}_{{\varvec{P}}}\rangle$$ of EMS-combined bicycle condition tended to be larger than $$\Delta \langle {{\varvec{\sigma}}}_{{\varvec{P}}}\rangle$$ of bicycle condition ( $${\varvec{\beta}}=12.85,{\varvec{p}}<0.05$$ ). The key findings are that HPLT and EMS-combined bicycle condition are a more efficient bicycle training than LPHT and bicycle condition for increasing $$\Delta \langle {{\varvec{\sigma}}}_{{\varvec{P}}}\rangle$$ .- 22 January 2026
- Published by Springer Nature in Annals of Biomedical Engineering
- Vol. 54 (6) , 1709-1722
Open AccessConductive Response Imaging in Thigh Muscle Compartments by Electrical Impedance Tomography for Efficient Bicycle Training Strategy
The conductive response in thigh muscle compartments has been imaged by electrical impedance tomography (EIT) under bicycle-operation conditions and muscle-stimulation conditions to determine an efficient training strategy. EIT is already applied to evaluate the effectiveness of electrical muscle stimulation (EMS) on human muscle, and hybrid of EMS which combines EMS on biceps and voluntary resistance training simultaneously. In this study, we newly applied EIT to the thigh muscle compartments and imaged the conductive response under bicycle-operation conditions and muscle-stimulation conditions. The bicycle-operation conditions are high pedal rate in low torque (HPLT) and low pedal rate in high torque (LPHT). The muscle-stimulation conditions are bicycle condition and EMS-combined bicycle condition. As a result, EIT successfully imaged the conductive response in three muscle compartments which are T1 compartment (quadriceps), T2 compartment (hamstrings), and T3 compartment (other than the quadriceps and hamstrings). The spatial-mean conductivity changes $$\Delta \langle {{\varvec{\sigma}}}_{{\varvec{P}}}\rangle$$ (the power of bicycle training $${\varvec{P}}=103,152,\mathbf{o}\mathbf{r}194[\mathbf{W}]$$ ) increased with increasing power $${\varvec{P}}$$ of the bicycle training across all four conditions and in all muscle compartments ( $${\varvec{\beta}}=0.531,\boldsymbol{ }{\varvec{p}}<0.001$$ ). The $$\Delta \langle {{\varvec{\sigma}}}_{{\varvec{P}}}\rangle$$ of HPLT tended to be larger than $$\Delta \langle {{\varvec{\sigma}}}_{{\varvec{P}}}\rangle$$ of LPHT ( $${\varvec{\beta}}=-35.52,\boldsymbol{ }{\varvec{p}}<0.001$$ ). The $$\Delta \langle {{\varvec{\sigma}}}_{{\varvec{P}}}\rangle$$ of EMS-combined bicycle condition tended to be larger than $$\Delta \langle {{\varvec{\sigma}}}_{{\varvec{P}}}\rangle$$ of bicycle condition ( $${\varvec{\beta}}=12.85,{\varvec{p}}<0.05$$ ). The key findings are that HPLT and EMS-combined bicycle condition are a more efficient bicycle training than LPHT and bicycle condition for increasing $$\Delta \langle {{\varvec{\sigma}}}_{{\varvec{P}}}\rangle$$ . - 20 January 2026
- Published by IOP Publishing in Medical Engineering & Physics
- Vol. 147 (2) , 025002
Assessment of gastric electrical impedance tomography by 13 C-acetate breath test for gastric retention evaluation
The gastric electrical impedance tomography (gEIT) has been assessed by the conventional13C-acetate breath test (BT) for gastric retention evaluation. ThegEIT images the conductivity distribution of the gastric volumeVtmin the stomach. ThegEIT was applied to seven healthy subjects during gastric emptying under the experimental conditions which are (i) frequencies of applied current is 30 kHz and 200 ml of 200 kcal liquid meal added with 100 mg sodium acetate- 1-13C. During the 90 min of measurement time, thegEIT measured each subject at five-minutes intervals, followed by the BT measurement. ThegEIT calculated the gastric volumeVtm[%] based on the gastric conductivity distributionσobtained from the reconstructed image. Fifty percent completion time of gastric emptyingt50and13CO2-peak exhalation timetmaxwere used as parameters to characterize gastric emptying during the BT. ThegEIT images the conductivity distribution of the gastric volumeVtm[%] in the abdomen. The experimental results show gEIT is strongly correlated with BT between the values oftmaxandt50at frequency of 30 kHz, which indicates a low error in the gastric retention evaluation.gEIT proves to be a reliable, non-radioactive alternative for gastric retention evaluation.
- 20 January 2026
- Published by IOP Publishing in Medical Engineering & Physics
- Vol. 147 (2) , 025002
Assessment of gastric electrical impedance tomography by 13 C-acetate breath test for gastric retention evaluation
The gastric electrical impedance tomography (gEIT) has been assessed by the conventional13C-acetate breath test (BT) for gastric retention evaluation. ThegEIT images the conductivity distribution of the gastric volumeVtmin the stomach. ThegEIT was applied to seven healthy subjects during gastric emptying under the experimental conditions which are (i) frequencies of applied current is 30 kHz and 200 ml of 200 kcal liquid meal added with 100 mg sodium acetate- 1-13C. During the 90 min of measurement time, thegEIT measured each subject at five-minutes intervals, followed by the BT measurement. ThegEIT calculated the gastric volumeVtm[%] based on the gastric conductivity distributionσobtained from the reconstructed image. Fifty percent completion time of gastric emptyingt50and13CO2-peak exhalation timetmaxwere used as parameters to characterize gastric emptying during the BT. ThegEIT images the conductivity distribution of the gastric volumeVtm[%] in the abdomen. The experimental results show gEIT is strongly correlated with BT between the values oftmaxandt50at frequency of 30 kHz, which indicates a low error in the gastric retention evaluation.gEIT proves to be a reliable, non-radioactive alternative for gastric retention evaluation.
- 19 September 2024
- Published by IOP Publishing in Biomedical Physics & Engineering Express
- Vol. 10 (6) , 065022
Detection of invasive ductal carcinoma by electrical impedance spectroscopy implementing gaussian relaxation-time distribution (EIS-GRTD)
Breast cancer detection and differentiation of breast tissues are critical for accurate diagnosis and treatment planning. This study addresses the challenge of distinguishing between invasive ductal carcinoma (IDC), normal glandular breast tissues (nGBT), and adipose tissue using electrical impedance spectroscopy combined with Gaussian relaxation-time distribution (EIS-GRTD). The primary objective is to investigate the relaxation-time characteristics of these tissues and their potential to differentiate between normal and abnormal breast tissues. We applied a single-point EIS-GRTD measurement to ten mastectomy specimens across a frequency range f = 4 Hz to 5 MHz. The method calculates the differential ratio of the relaxation-time distribution function Δ γ between IDC and nGBT, which is denoted by Δ γ IDC − nGBT , and Δ γ between IDC and adipose tissues, which is denoted by Δ γ IDC − adipose . As a result, the differential ratio of Δ γ between IDC and nGBT Δ γ IDC − nGBT is 0.36, and between IDC and adipose Δ γ IDC − adipose is 0.27, which included in the α -dispersion at τ peak 1 = 0.033 ± 0.001 s . In all specimens, the relaxation-time distribution function γ of IDC γ IDC is higher, and there is no intersection with γ of nGBT γ nGBT and adipose γ adipose . The difference in γ suggests potential variations in relaxation properties at the molecular or structural level within each breast tissue that contribute to the overall relaxation response. The average mean percentage error δ for IDC, nGBT, and adipose tissues are 5.90%, 6.33%, and 8.07%, respectively, demonstrating the model’s accuracy and reliability. This study provides novel insights into the use of relaxation-time characteristic for differentiating breast tissue types, offering potential advancements in diagnosis methods. Future research will focus on correlating EIS-GRTD finding with pathological results from the same test sites to further validate the method’s efficacy.
- 19 September 2024
- Published by IOP Publishing in Biomedical Physics & Engineering Express
- Vol. 10 (6) , 065022
Detection of invasive ductal carcinoma by electrical impedance spectroscopy implementing gaussian relaxation-time distribution (EIS-GRTD)
Breast cancer detection and differentiation of breast tissues are critical for accurate diagnosis and treatment planning. This study addresses the challenge of distinguishing between invasive ductal carcinoma (IDC), normal glandular breast tissues (nGBT), and adipose tissue using electrical impedance spectroscopy combined with Gaussian relaxation-time distribution (EIS-GRTD). The primary objective is to investigate the relaxation-time characteristics of these tissues and their potential to differentiate between normal and abnormal breast tissues. We applied a single-point EIS-GRTD measurement to ten mastectomy specimens across a frequency range f = 4 Hz to 5 MHz. The method calculates the differential ratio of the relaxation-time distribution function Δ γ between IDC and nGBT, which is denoted by Δ γ IDC − nGBT , and Δ γ between IDC and adipose tissues, which is denoted by Δ γ IDC − adipose . As a result, the differential ratio of Δ γ between IDC and nGBT Δ γ IDC − nGBT is 0.36, and between IDC and adipose Δ γ IDC − adipose is 0.27, which included in the α -dispersion at τ peak 1 = 0.033 ± 0.001 s . In all specimens, the relaxation-time distribution function γ of IDC γ IDC is higher, and there is no intersection with γ of nGBT γ nGBT and adipose γ adipose . The difference in γ suggests potential variations in relaxation properties at the molecular or structural level within each breast tissue that contribute to the overall relaxation response. The average mean percentage error δ for IDC, nGBT, and adipose tissues are 5.90%, 6.33%, and 8.07%, respectively, demonstrating the model’s accuracy and reliability. This study provides novel insights into the use of relaxation-time characteristic for differentiating breast tissue types, offering potential advancements in diagnosis methods. Future research will focus on correlating EIS-GRTD finding with pathological results from the same test sites to further validate the method’s efficacy.
- 11 July 2024
- Published by IOP Publishing in Biomedical Physics & Engineering Express
- Vol. 10 (5) , 055007
Detection of invasive ductal carcinoma in quadrant breast areas by electrical impedance tomography implemented with gaussian relaxation-time distribution (EIT-GRTD)
Invasive ductal carcinoma (IDC) in breast specimens has been detected in the quadrant breast area: (I) upper outer, (II) upper inner, (III) lower inner, and (IV) lower outer areas by electrical impedance tomography implemented with Gaussian relaxation-time distribution (EIT-GRTD). The EIT-GRTD consists of two steps which are (1) the optimum frequency f opt selection and (2) the time constant enhancement of breast imaging reconstruction. f opt is characterized by a peak in the majority measurement pair of the relaxation-time distribution function γ , which indicates the presence of IDC. γ represents the inverse of conductivity and indicates the response of breast tissues to electrical currents across varying frequencies based on the Voigt circuit model. The EIT-GRTD is quantitatively evaluated by multi-physics simulations using a hemisphere container of mimic breast, consisting of IDC and adipose tissues as normal breast tissue under one condition with known IDC in quadrant breast area II. The simulation results show that EIT-GRTD is able to detect the IDC in four layers at f opt = 30, 170 Hz. EIT-GRTD is applied in the real breast by employed six mastectomy specimens from IDC patients. The placement of the mastectomy specimens in a hemisphere container is an important factor in the success of quadrant breast area reconstruction. In order to perform the evaluation, EIT-GRTD reconstruction images are compared to the CT scan images. The experimental results demonstrate that EIS-GRTD exhibits proficiency in the detection of the IDC in quadrant breast areas while compared qualitatively to CT scan images.
- 11 July 2024
- Published by IOP Publishing in Biomedical Physics & Engineering Express
- Vol. 10 (5) , 055007
Detection of invasive ductal carcinoma in quadrant breast areas by electrical impedance tomography implemented with gaussian relaxation-time distribution (EIT-GRTD)
Invasive ductal carcinoma (IDC) in breast specimens has been detected in the quadrant breast area: (I) upper outer, (II) upper inner, (III) lower inner, and (IV) lower outer areas by electrical impedance tomography implemented with Gaussian relaxation-time distribution (EIT-GRTD). The EIT-GRTD consists of two steps which are (1) the optimum frequency f opt selection and (2) the time constant enhancement of breast imaging reconstruction. f opt is characterized by a peak in the majority measurement pair of the relaxation-time distribution function γ , which indicates the presence of IDC. γ represents the inverse of conductivity and indicates the response of breast tissues to electrical currents across varying frequencies based on the Voigt circuit model. The EIT-GRTD is quantitatively evaluated by multi-physics simulations using a hemisphere container of mimic breast, consisting of IDC and adipose tissues as normal breast tissue under one condition with known IDC in quadrant breast area II. The simulation results show that EIT-GRTD is able to detect the IDC in four layers at f opt = 30, 170 Hz. EIT-GRTD is applied in the real breast by employed six mastectomy specimens from IDC patients. The placement of the mastectomy specimens in a hemisphere container is an important factor in the success of quadrant breast area reconstruction. In order to perform the evaluation, EIT-GRTD reconstruction images are compared to the CT scan images. The experimental results demonstrate that EIS-GRTD exhibits proficiency in the detection of the IDC in quadrant breast areas while compared qualitatively to CT scan images.
- 15 February 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 73 (00189456) , 1-13
Sodium-Ion Concentration Extraction in Dermis Layer by Time-Constant-Domain Electrical Impedance Spectroscopy (TCD-EIS) With Dermis Separation Model (DSM)
Sodium-ion concentration c in the dermis layer has been extracted by time-constant-domain electrical impedance spectroscopy (TCD-EIS) with the dermis separation model (DSM). The TCD-EIS with DSM consists of the dermis separation formulation, ridge regression optimization, and distribution relaxation times (DRT) with radial base function. To distinguish the relaxation time of the dermis τ d from the other layers (stratum corneum τ sc , the epidermis τ e , and the fat layer τ f ), the subtracted impedivity was calculated by distant electrode pair z 1 , and close the electrode pair z 2 , based on optimum electrode diameter ϕ and distance l . The numerical optimizations were implemented to optimize ϕ from 0.5 to 3 mm and l from 2 to 8 mm, regarded as DSM sensor parameters. In the simulation, the optimized DSM sensor parameters, ϕ*=1 mm and l *=1 mm, were applied to the skin model under the condition of 1) various sodium-ion concentrations c in the dermis layer, 2) frequencies f from 100 Hz to 1 MHz. In the experiments, the optimized TCD-EIS with DSM was applied to porcine skin under the condition following the simulations. The relation between the distribution function γ and relaxation times τ, were used to evaluate the sodium-ion concentration extraction. Both simulation and experiment results show that the normalized distribution function of the dermis γ* c (ln τ d )decreases with the increase of sodium-ion concentration c . The sodium-ion concentration c in the dermis layer was distinguished properly at dermis relaxation times τ d =10 -2 [s]. TCD-EIS with DSM reveals that the decrease of a normalized distribution function γ* c (ln τ d ), correlates with the increased sodium-ion concentration c injected in the dermis layer.
- 15 February 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 73 (00189456) , 1-13
Sodium-Ion Concentration Extraction in Dermis Layer by Time-Constant-Domain Electrical Impedance Spectroscopy (TCD-EIS) With Dermis Separation Model (DSM)
Sodium-ion concentration c in the dermis layer has been extracted by time-constant-domain electrical impedance spectroscopy (TCD-EIS) with the dermis separation model (DSM). The TCD-EIS with DSM consists of the dermis separation formulation, ridge regression optimization, and distribution relaxation times (DRT) with radial base function. To distinguish the relaxation time of the dermis τ d from the other layers (stratum corneum τ sc , the epidermis τ e , and the fat layer τ f ), the subtracted impedivity was calculated by distant electrode pair z 1 , and close the electrode pair z 2 , based on optimum electrode diameter ϕ and distance l . The numerical optimizations were implemented to optimize ϕ from 0.5 to 3 mm and l from 2 to 8 mm, regarded as DSM sensor parameters. In the simulation, the optimized DSM sensor parameters, ϕ*=1 mm and l *=1 mm, were applied to the skin model under the condition of 1) various sodium-ion concentrations c in the dermis layer, 2) frequencies f from 100 Hz to 1 MHz. In the experiments, the optimized TCD-EIS with DSM was applied to porcine skin under the condition following the simulations. The relation between the distribution function γ and relaxation times τ, were used to evaluate the sodium-ion concentration extraction. Both simulation and experiment results show that the normalized distribution function of the dermis γ* c (ln τ d )decreases with the increase of sodium-ion concentration c . The sodium-ion concentration c in the dermis layer was distinguished properly at dermis relaxation times τ d =10 -2 [s]. TCD-EIS with DSM reveals that the decrease of a normalized distribution function γ* c (ln τ d ), correlates with the increased sodium-ion concentration c injected in the dermis layer.
- Open Access
Metal Particle Detection by Integration of a Generative Adversarial Network and Electrical Impedance Tomography (GAN-EIT) for a Wet-Type Gravity Vibration Separator
The minor copper (Cu) particles among major aluminum (Al) particles have been detected by means of an integration of a generative adversarial network and electrical impedance tomography (GAN-EIT) for a wet-type gravity vibration separator (WGS). This study solves the problem of blurred EIT reconstructed images by proposing a GAN-EIT integration system for Cu detection in WGS. GAN-EIT produces two types of images of various Cu positions among major Al particles, which are (1) the photo-based GAN-EIT images, where blurred EIT reconstructed images are enhanced by GAN based on a full set of photo images, and (2) the simulation-based GAN-EIT images. The proposed metal particle detection by GAN-EIT is applied in experiments under static conditions to investigate the performance of the metal detection method under single-layer conditions with the variation of the position of Cu particles. As a quantitative result, the images of detected Cu by GAN-EIT in different positions have higher accuracy as compared to . In the region of interest (ROI) covered by the developed linear sensor, GAN-EIT successfully reduces the Cu detection error of conventional EIT by 40% while maintaining a minimum signal-to-noise ratio (SNR) of 60 [dB]. In conclusion, GAN-EIT is capable of improving the detailed features of the reconstructed images to visualize the detected Cu effectively.Open AccessMetal Particle Detection by Integration of a Generative Adversarial Network and Electrical Impedance Tomography (GAN-EIT) for a Wet-Type Gravity Vibration Separator
The minor copper (Cu) particles among major aluminum (Al) particles have been detected by means of an integration of a generative adversarial network and electrical impedance tomography (GAN-EIT) for a wet-type gravity vibration separator (WGS). This study solves the problem of blurred EIT reconstructed images by proposing a GAN-EIT integration system for Cu detection in WGS. GAN-EIT produces two types of images of various Cu positions among major Al particles, which are (1) the photo-based GAN-EIT images, where blurred EIT reconstructed images are enhanced by GAN based on a full set of photo images, and (2) the simulation-based GAN-EIT images. The proposed metal particle detection by GAN-EIT is applied in experiments under static conditions to investigate the performance of the metal detection method under single-layer conditions with the variation of the position of Cu particles. As a quantitative result, the images of detected Cu by GAN-EIT in different positions have higher accuracy as compared to . In the region of interest (ROI) covered by the developed linear sensor, GAN-EIT successfully reduces the Cu detection error of conventional EIT by 40% while maintaining a minimum signal-to-noise ratio (SNR) of 60 [dB]. In conclusion, GAN-EIT is capable of improving the detailed features of the reconstructed images to visualize the detected Cu effectively. - 27 July 2023
- Published by IOP Publishing in Biomedical Physics & Engineering Express
- Vol. 9 (5) , 055010
Free and bound sodium identification by skin dielectric properties separation algorithm of bioelectrical impedance spectroscopy (spa-BIS) in human skin model
Free and bound sodium in human skin models have been identified by two proposals: skin’s phantom fabrication and skin’s dielectric properties separation algorithm of bioelectrical impedance spectroscopy (spa-BIS). The spa-BIS consist of conductivity-permittivity separation, contact impedance compensation, and a correlation score algorithm based on the vessel with a bipolar electrode. The skin phantom fabrication comprises a recipe combination with temperature-controlled protocol and sodium molarity calculation. In experiments, the human skin models are created to mimic the electrical properties of skin under 1 MHz with several different sodium molarities. Based on five types of human skin models with five samples of each group, the free sodium type conductivity and concentration results R 2 = 0.9903 − following a linear trendline of concentration change in skin tissues theorems with the fRequency range from 1 kHz to 1 MHz , while the bound sodium type results R 2 = 0.9061 − . The spa-BIS compensate 7 − 16 Ω of vessel contact impedance. The dielectric properties of each type have been extracted with less than 10% of the average standard deviation, which is considered an accurate identification method of dermis dielectric properties. The algorithm successfully identifies sodium type: free sodium has a negative, and bound sodium has a positive correlation score trend. As an additional discussion, the different time-dependent effects, the different water content, and different agar content analyses have been provided in this study. As a robust analysis method, the spa-BIS has a prominent performance to replace a 23Na-MRI in terms of free and bound sodium identification.
- 27 July 2023
- Published by IOP Publishing in Biomedical Physics & Engineering Express
- Vol. 9 (5) , 055010
Free and bound sodium identification by skin dielectric properties separation algorithm of bioelectrical impedance spectroscopy (spa-BIS) in human skin model
Free and bound sodium in human skin models have been identified by two proposals: skin’s phantom fabrication and skin’s dielectric properties separation algorithm of bioelectrical impedance spectroscopy (spa-BIS). The spa-BIS consist of conductivity-permittivity separation, contact impedance compensation, and a correlation score algorithm based on the vessel with a bipolar electrode. The skin phantom fabrication comprises a recipe combination with temperature-controlled protocol and sodium molarity calculation. In experiments, the human skin models are created to mimic the electrical properties of skin under 1 MHz with several different sodium molarities. Based on five types of human skin models with five samples of each group, the free sodium type conductivity and concentration results R 2 = 0.9903 − following a linear trendline of concentration change in skin tissues theorems with the fRequency range from 1 kHz to 1 MHz , while the bound sodium type results R 2 = 0.9061 − . The spa-BIS compensate 7 − 16 Ω of vessel contact impedance. The dielectric properties of each type have been extracted with less than 10% of the average standard deviation, which is considered an accurate identification method of dermis dielectric properties. The algorithm successfully identifies sodium type: free sodium has a negative, and bound sodium has a positive correlation score trend. As an additional discussion, the different time-dependent effects, the different water content, and different agar content analyses have been provided in this study. As a robust analysis method, the spa-BIS has a prominent performance to replace a 23Na-MRI in terms of free and bound sodium identification.