SGSeth A. Gross

Seth A. Gross

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Seth A. Gross has a total of 15 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Use of Mechanical Enhanced Colonoscopy to Improve Polyp Detection During Colorectal Cancer Screening: A Real-World Healthcare Database Analysis

    by Abraham Z. Cheloff, Seth A. Gross

    Introduction: High performance colonoscopy requires the monitoring of an individual’s adenoma detection rate (ADR). The Endocuff (EndoCuff Vision, Olympus America Inc., Center Valley, PA, USA) is an endoscopic distal attachment device that increases surface area exposure during colonoscopy. While studies have shown that Endocuff increased ADR, real-world data is limited on its effectiveness. Methods: The Premiere Health Database was reviewed from 2018 to 2021 to identify patients 50 years of age or older who had a screening colonoscopy. A keyword search for “Endocuff” was used to determine if Endocuff was utilized, and ICD10 codes were analyzed to determine if a polyp was found. Our primary outcome was a polyp detection rate (PDR) for Endocuff-assisted colonoscopy (EAC) and standard colonoscopy (SC). Secondary outcomes included an estimated adenoma detection rate (eADR). Logistic regression modeling was performed to examine the difference in PDR between the EAC and SC groups after controlling for baseline characteristics, insurance type, and provider experience. Results: Gastroenterologists performed 893,560 screening colonoscopies, of which 0.7% were Endocuff-assisted, while surgeons performed 234,962 screening colonoscopies and 0.5% were Endocuff-assisted. PDR was higher with EAC for both gastroenterologists (72.0% vs. 57.4%) and surgeons (55.6% vs. 43.7%), with eADR following similar trends. The odds ratio of polyp detection with vs. without Endocuff was 1.91 for gastroenterologists and 1.62 for surgeons. After adjusting for patient and provider factors, the adjusted odds ratios are 2.01 and 1.61, respectively. Conclusions: While Endocuff utilization remains low, this large study using real-world data demonstrates the ability to improve eADR by over 10% compared to standard colonoscopy.


  • Open Access

    Artificial Intelligence–Assisted Optical Diagnosis: A Comprehensive Review of Its Role in Leave-In-Situ and Resect-and-Discard Strategies in Colonoscopy

    by Maysaa El Zoghbi, Aasma Shaukat, Cesare Hassan, Joseph C. Anderson, Alessandro Repici, Seth A. Gross

    Colorectal cancer screening plays a vital role in early detection and removal of precancerous adenomas, contributing to decreased mortality rates. Most polyps found during colonoscopies are small and unlikely to harbor advanced neoplasia or invasive cancer, leading to the development of “leave-in-situ” and “resect-and-discard” approaches. These strategies could lead to significant cost savings and efficiencies, but their implementation has been hampered by concerns around financial incentives, medical-legal risks, and local rules for tissue handling. This article reviews the potential of artificial intelligence to enhance the accuracy of polyp diagnosis through computer-aided diagnosis (CADx). While the adoption of CADx in optical biopsy has shown mixed results, it has the potential to significantly improve the management of colorectal polyps. Several studies reviewed in this article highlight the varied results of CADx in optical biopsy for colorectal polyps. Although artificial intelligence does not consistently outperform expert endoscopists, it has the potential to serve as a beneficial secondary reader, aiding in accurate optical diagnosis and increasing the confidence of the endoscopist. These studies indicate that although CADx holds great potential, it is yet to fully meet the performance thresholds necessary for clinical implementation.


  • Colorectal Cancer and Polyp Detection Using a New Preparation-Free, Colon-Scan Capsule: A Pilot Study of Safety and Patient Satisfaction

    by Ana Garcia Garcia de Paredes, Seth A. Gross, Ariosto H. Hernandez-Lara, Stephanie L. Hansel, David M. Poppers, Elizabeth Rajan

    Background Current strategies to prevent colorectal cancer (CRC) vary considerably regarding safety, invasiveness, and patient satisfaction. A known deterrent for patients is the required bowel cleansing for colonoscopy. A new colon-scan capsule system is a unique preparation-free approach that provides structural information on colonic mucosa intended for detection of colorectal polyps and masses. Aims The aim of this study was to determine safety and patient satisfaction with the colon-scan capsule. Methods Prospective single-arm pilot study conducted at two tertiary care centers. Patients with a pre-scheduled colonoscopy for CRC screening or surveillance were included. Patients participating in this study underwent the colon-scan capsule and colonoscopy. Safety was defined by the occurrence of procedure or device-related adverse events. Satisfaction was based on survey questionnaires using a scoring system 1 (strongly disagree) to 5 (strongly agree). Patient satisfaction with the colon-scan capsule was compared to colonoscopy. Results Forty patients were included (52.9 [5.7] years; 64.1% females). There were no serious adverse events and no occurrences of capsule retention. The most common (12.5%) complaint was self-limiting abdominal cramping. Satisfaction questionnaires were completed by more than 87% of patients, with patients likely to recommend the capsule (score 4.1 [1.03]) compared to colonoscopy (score 2.8 [1.2]), p = 0.001. Conclusions The new prepless colon-scan capsule system is an innovative, minimally invasive technology with demonstrated safety and high patient satisfaction. A multicenter pivotal study is planned to validate the performance, safety, and accuracy of polyp detection using the capsule system in comparison with colonoscopy.


  • Open Access

    TeleInGEstion Remote Video Capsule Endoscope

    by Aditya Sreenivasan, Tianyu She, Seth Gross, Ian Storch

    We describe 2 cases in which video capsule endoscopy was performed remotely using TeleInGEstion Remote Video Capsule Endoscopy (TIGER VCE), given limited access to endoscopy during the COVID-19 pandemic. The patients ingested the CapsoCam capsule during a televisit, and the video was subsequently reviewed remotely by the physician. TIGER VCE was used to diagnose a benign etiology of melena and used to confirm a diagnosis of Crohn's disease before the initiation of biologic therapy. These cases demonstrate the safety and efficacy of TIGER VCE. We feel that this technique may be considered as a standard ingestion technique in the future.


  • The Use of Attachment Devices to Aid in Adenoma Detection

    by Zoe Lawrence, Seth A. Gross

    Purpose of review With the intent of maximizing adenoma detection rate (ADR), different devices and colonoscopic innovations have been introduced over the past few years. There are a variety of attachment devices available for use in colonoscopy, all intended to improve ADR. In this review, we evaluate the evidence surrounding the available attachment devices and their impact on ADR. Recent findings Endocuff, Endoring, Transparent cap, G-EYE balloon, and Third Eye Retroscope were all included in this review. Three of the devices, Endocuff, Endoring, and transparent hood or cap, have been shown to increase ADR without significantly altering the use of the colonoscope. Although balloon-assisted colonoscopy is not currently FDA-approved, it has the potential to increase ADR as well. Summary Mechanical enhancement has been shown to complement the current forward-viewing colonoscope, and Endocuff appears to be the most beneficial attachment to improve ADR.