Chie Kaminuma
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Chie Kaminuma has a total of 6 co-authors. Here are the top co-authors by number of shared publications:
Ayako Taketomi-Takahashi
Department of Nuclear Medicine, Gunma University Hospital, Gunma, Japan
2 shared publicationsYoshito Tsushima
Department of Nuclear Medicine, Gunma University Hospital, Gunma, Japan
2 shared publicationsKeigo Endo
Department of Diagnostic Radiology and Nuclear Medicine, Gunma University Hospital, Gunma, Japan
1 shared publicationNoriko Matsumoto
Department of Diagnostic Radiology and Nuclear Medicine, Gunma University Hospital, Gunma, Japan
1 shared publicationNoriko Yamanaka
Department of Diagnostic Radiology and Nuclear Medicine, Gunma University Hospital, 3-39-22 Showa-machi, Maebashi, Gunma 371-8511, Japan
1 shared publicationTakemi Kurabayashi
Department of Diagnostic Radiology and Nuclear Medicine, Gunma University Hospital, Gunma, Japan
1 shared publication
Latest Publications
- 1 August 2012
- Published by Wiley in Journal of Ultrasound in Medicine
- Vol. 31 (8) , 1239-1244
Reliable Measurement by Virtual Touch Tissue Quantification With Acoustic Radiation Force Impulse Imaging
Objectives The purpose of this study was to evaluate the factors that may affect shear wave velocity (SWV) measurements by using a phantom. Methods The SWVs (meters per second) of 4 phantom target...
- 1 August 2012
- Published by Wiley in Journal of Ultrasound in Medicine
- Vol. 31 (8) , 1239-1244
Reliable Measurement by Virtual Touch Tissue Quantification With Acoustic Radiation Force Impulse Imaging
Objectives The purpose of this study was to evaluate the factors that may affect shear wave velocity (SWV) measurements by using a phantom. Methods The SWVs (meters per second) of 4 phantom target...
- Open Access
- 1 June 2011
- Published by Wiley in Journal of Ultrasound in Medicine
- Vol. 30 (6) , 745-751
Reliable Measurement Procedure of Virtual Touch Tissue Quantification With Acoustic Radiation Force Impulse Imaging
Objectives The purpose of this study was to find a reliable procedure for performing virtual touch tissue quantification of the liver. Methods Twenty healthy volunteers were enrolled after informed consent was obtained. The liver and spleen of each volunteer were examined on the same day by two different sonologists. The shear wave velocity values at deep and superficial locations of the right and left lobes of the liver and the spleen were obtained before and after food consumption and with and without deep inspiration. The measurements were performed 5 times in each location, and the mean shear wave velocities were recorded. Results No statistically significant difference was found between the mean shear wave velocities obtained by the two operators. A difference was found between the velocities obtained in the deep portion of the right lobe (5.5 cm from the probe; mean ± SD, 1.17 ± 0.25 m/s on the intercostal scan and 1.35 ± 0.45 m/s on the subcostal scan) and the superficial portion (3.5 cm; 1.56 ± 0.43 and 1.74 ± 0.74 m/s; P < .001; P < .002, respectively), and the values obtained in the deep portion of the right lobe on the intercostal scan were lower than those obtained on the subcostal scan (P < .05). There were no differences in the mean shear wave velocities of the liver before and after food consumption or with and without deep inspiration. The velocities of the spleen did not differ before and after food consumption (2.33 ± 0.47 versus 2.39 ± 0.58 m/s). Conclusions In healthy people, mean shear wave velocities were dependent on the measurement site in the liver, and food consumption or deep inspiration did not affect velocity measurements of the liver or spleen.
- 1 June 2011
- Published by Wiley in Journal of Ultrasound in Medicine
- Vol. 30 (6) , 745-751
Open AccessReliable Measurement Procedure of Virtual Touch Tissue Quantification With Acoustic Radiation Force Impulse Imaging
Objectives The purpose of this study was to find a reliable procedure for performing virtual touch tissue quantification of the liver. Methods Twenty healthy volunteers were enrolled after informed consent was obtained. The liver and spleen of each volunteer were examined on the same day by two different sonologists. The shear wave velocity values at deep and superficial locations of the right and left lobes of the liver and the spleen were obtained before and after food consumption and with and without deep inspiration. The measurements were performed 5 times in each location, and the mean shear wave velocities were recorded. Results No statistically significant difference was found between the mean shear wave velocities obtained by the two operators. A difference was found between the velocities obtained in the deep portion of the right lobe (5.5 cm from the probe; mean ± SD, 1.17 ± 0.25 m/s on the intercostal scan and 1.35 ± 0.45 m/s on the subcostal scan) and the superficial portion (3.5 cm; 1.56 ± 0.43 and 1.74 ± 0.74 m/s; P < .001; P < .002, respectively), and the values obtained in the deep portion of the right lobe on the intercostal scan were lower than those obtained on the subcostal scan (P < .05). There were no differences in the mean shear wave velocities of the liver before and after food consumption or with and without deep inspiration. The velocities of the spleen did not differ before and after food consumption (2.33 ± 0.47 versus 2.39 ± 0.58 m/s). Conclusions In healthy people, mean shear wave velocities were dependent on the measurement site in the liver, and food consumption or deep inspiration did not affect velocity measurements of the liver or spleen.