VPVan Binh Pham

Van Binh Pham

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Van Binh Pham has a total of 6 co-authors. Here are the top co-authors by number of shared publications:

  • Mau Chien Dang

    Institute for Nanotechnology, Ho Chi Minh City 700000, Vietnam

    2 shared publications
  • Thanh Nhat Khoa Phan

    Laboratory for Nanotechnology, Vietnam National University in Ho Chi Minh City, Community 6, LinhTrung Ward, Thu Duc District, Ho Chi Minh City, Vietnam

    2 shared publications
  • Thi Thanh Tuyen Le

    Laboratory for Nanotechnology, Vietnam National University in Ho Chi Minh City, Community 6, LinhTrung Ward, Thu Duc District, Ho Chi Minh City, Vietnam

    2 shared publications
  • Thanh Trung Nguyen

    Laboratory for Nanotechnology, Vietnam National University in Ho Chi Minh City, Community 6, LinhTrung Ward, Thu Duc District, Ho Chi Minh City, Vietnam

    1 shared publication
  • Xuan Thanh Tung Pham

    Laboratory for Nanotechnology, Vietnam National University in Ho Chi Minh City, Community 6, LinhTrung Ward, Thu Duc District, Ho Chi Minh City, Vietnam

    1 shared publication
  • Xuan ThanhTung Pham

    Laboratory for Nanotechnology (LNT), Vietnam National University in Ho Chi Minh City, Community 6, Linh Trung Ward, Thu Duc District, Ho Chi Minh City, Vietnam

    1 shared publication

Latest Publications

  • Open Access

    Surface modification of a gold-coated microcantilever and application in biomarker detection

    by Van Binh Pham, Thanh Nhat Khoa Phan, Thanh Trung Nguyen, Xuan Thanh Tung Pham, Thi Thanh Tuyen Le, Mau Chien Dang

    Biosensors have been rapidly developed recently. Biological receptors, such as antibodies, must be immobilized on these sensors' surfaces to make the sensor capable of capturing a target analyte. In this research we studied how to modify a gold-coated surface of a microcantilever, a sensor with high potential in biological and medical applications. Thiol chemistry was adapted to create a cysteamine layer on a gold surface, and subsequently glutaraldehyde was used as a cross-linking agent to react with amine groups in receptors. In order to evaluate the efficiency of immobilizing protein on an Au surface and also whether the protein retains its biological activity, horseradish peroxidase enzyme (HRP) with its activity to catalyze a reaction between 2,2'-azino-bis [3-ethylbenzothiazoline-6-sulphonic acid] (ABTS) and was used as a testing protein. The result showed that HRP was immobilized successfully on cysteamine and glutaraldehyde layers and retained its activity. The cantilever's tip deflection was also measured, and results showed that each layer created surface stress and made the cantilever bend—in particular, the cysteamine layer induced bending as high as 6 μm. An antibody of alpha-fetoprotein (AFP) was immobilized on the cantilever surface, and the measurement deflection showed that the sensor responded to solution containing AFP with concentration from 100 to 500 ng ml−1.

  • Open Access

    Facile fabrication of a silicon nanowire sensor by two size reduction steps for detection of alpha-fetoprotein biomarker of liver cancer

    by Van Binh Pham, Xuan ThanhTung Pham, Thanh Nhat Khoa Phan, Thi Thanh Tuyen Le, Mau Chien Dang

    We present a facile technique that only uses conventional micro-techniques and two size-reduction steps to fabricate wafer-scale silicon nanowire (SiNW) with widths of 200 nm. Initially, conventional lithography was used to pattern SiNW with 2 μm width. Then the nanowire width was decreased to 200 nm by two size-reduction steps with isotropic wet etching. The fabricated SiNW was further investigated when used with nanowire field-effect sensors. The electrical characteristics of the fabricated SiNW devices were characterized and pH sensitivity was investigated. Then a simple and effective surface modification process was carried out to modify SiNW for subsequent binding of a desired receptor. The complete SiNW-based biosensor was then used to detect alpha-fetoprotein (AFP), one of the medically approved biomarkers for liver cancer diagnosis. Electrical measurements showed that the developed SiNW biosensor could detect AFP with concentrations of about 100 ng mL−1. This concentration is lower than the necessary AFP concentration for liver cancer diagnosis.