Jan S. Dam
Research Subjects
Jan S. Dam has a total of 5 co-authors. Here are the top co-authors by number of shared publications:
Paul Erik Fabricius
J. S. Dam, C. B. Pedersen, T. Dalgaard, and P. E. Fabricius are with Bang & Olufsen Medicom a/s, DK-7600, Struer, Denmark.S. Andersson-Engels is with the Department of Physics, Lund Institute of Technology, P.O. Box 118, SE-22100, Lund, Sweden.P. Aruna is with Anna University, 600 025 Madras, India
2 shared publications- Stefan Andersson-Engels
University College Cork
2 shared publications Torben Dalgaard
J. S. Dam, C. B. Pedersen, T. Dalgaard, and P. E. Fabricius are with Bang & Olufsen Medicom a/s, DK-7600, Struer, Denmark.S. Andersson-Engels is with the Department of Physics, Lund Institute of Technology, P.O. Box 118, SE-22100, Lund, Sweden.P. Aruna is with Anna University, 600 025 Madras, India
2 shared publicationsCarsten B. Pedersen
J. S. Dam, C. B. Pedersen, T. Dalgaard, and P. E. Fabricius are with Bang & Olufsen Medicom a/s, DK-7600, Struer, Denmark.S. Andersson-Engels is with the Department of Physics, Lund Institute of Technology, P.O. Box 118, SE-22100, Lund, Sweden.P. Aruna is with Anna University, 600 025 Madras, India
1 shared publicationPrakasa Aruna
J. S. Dam, C. B. Pedersen, T. Dalgaard, and P. E. Fabricius are with Bang & Olufsen Medicom a/s, DK-7600, Struer, Denmark.S. Andersson-Engels is with the Department of Physics, Lund Institute of Technology, P.O. Box 118, SE-22100, Lund, Sweden.P. Aruna is with Anna University, 600 025 Madras, India
1 shared publication
Latest Publications
- 1 March 2001
- Published by Optica Publishing Group in Applied Optics
- Vol. 40 (7) , 1155-1164
Fiber-optic probe for noninvasive real-time determination of tissue optical properties at multiple wavelengths
We present a compact, fast, and versatile fiber-optic probe system for real-time determination of tissue optical properties from spatially resolved continuous-wave diffuse reflectance measurements. The system collects one set of reflectance data from six source–detector distances at four arbitrary wavelengths with a maximum overall sampling rate of 100 Hz. Multivariate calibration techniques based on two-dimensional polynomial fitting are employed to extract and display the absorption and reduced scattering coefficients in real-time mode. The four wavelengths of the current configuration are 660, 785, 805, and 974 nm, respectively. Cross-validation tests on a 6 × 7 calibration matrix of Intralipid–dye phantoms showed that the mean prediction error at, e.g., 785 nm was 2.8% for the absorption coefficient and 1.3% for the reduced scattering coefficient. The errors are relative to the range of the optical properties of the phantoms at 785 nm, which were 0–0.3/cm for the absorption coefficient and 6–16/cm for the reduced scattering coefficient. Finally, we also present and discuss results from preliminary skin tissue measurements.
- 1 March 2001
- Published by Optica Publishing Group in Applied Optics
- Vol. 40 (7) , 1155-1164
Fiber-optic probe for noninvasive real-time determination of tissue optical properties at multiple wavelengths
We present a compact, fast, and versatile fiber-optic probe system for real-time determination of tissue optical properties from spatially resolved continuous-wave diffuse reflectance measurements. The system collects one set of reflectance data from six source–detector distances at four arbitrary wavelengths with a maximum overall sampling rate of 100 Hz. Multivariate calibration techniques based on two-dimensional polynomial fitting are employed to extract and display the absorption and reduced scattering coefficients in real-time mode. The four wavelengths of the current configuration are 660, 785, 805, and 974 nm, respectively. Cross-validation tests on a 6 × 7 calibration matrix of Intralipid–dye phantoms showed that the mean prediction error at, e.g., 785 nm was 2.8% for the absorption coefficient and 1.3% for the reduced scattering coefficient. The errors are relative to the range of the optical properties of the phantoms at 785 nm, which were 0–0.3/cm for the absorption coefficient and 6–16/cm for the reduced scattering coefficient. Finally, we also present and discuss results from preliminary skin tissue measurements.
- 1 March 2000
- Published by Optica Publishing Group in Applied Optics
- Vol. 39 (7) , 1202-1209
Multiple polynomial regression method for determination of biomedical optical properties from integrating sphere measurements
We present a new, to our knowledge, method for extracting optical properties from integrating sphere measurements on thin biological samples. The method is based on multivariate calibration techniques involving Monte Carlo simulations, multiple polynomial regression, and a Newton–Raphson algorithm for solving nonlinear equation systems. Prediction tests with simulated data showed that the mean relative prediction error of the absorption and the reduced scattering coefficients within typical biological ranges were less than 0.3%. Similar tests with data from integrating sphere measurements on 20 dye–polystyrene microsphere phantoms led to mean errors less than 1.7% between predicted and theoretically calculated values. Comparisons showed that our method was more robust and typically 5–10 times as fast and accurate as two other established methods, i.e., the inverse adding–doubling method and the Monte Carlo spline interpolation method.
- 1 March 2000
- Published by Optica Publishing Group in Applied Optics
- Vol. 39 (7) , 1202-1209
Multiple polynomial regression method for determination of biomedical optical properties from integrating sphere measurements
We present a new, to our knowledge, method for extracting optical properties from integrating sphere measurements on thin biological samples. The method is based on multivariate calibration techniques involving Monte Carlo simulations, multiple polynomial regression, and a Newton–Raphson algorithm for solving nonlinear equation systems. Prediction tests with simulated data showed that the mean relative prediction error of the absorption and the reduced scattering coefficients within typical biological ranges were less than 0.3%. Similar tests with data from integrating sphere measurements on 20 dye–polystyrene microsphere phantoms led to mean errors less than 1.7% between predicted and theoretically calculated values. Comparisons showed that our method was more robust and typically 5–10 times as fast and accurate as two other established methods, i.e., the inverse adding–doubling method and the Monte Carlo spline interpolation method.