JWJing Wang

Jing Wang

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Jing Wang has a total of 5 co-authors. Here are the top co-authors by number of shared publications:

  • Hailin Yang

    Powder Metallurgy Research Institute, Central South University, Changsha, Hunan 410078, P.R. China

    1 shared publication
  • Jian Xu

    Department of Orthopedics, Huashan Hospital, Fudan University, Shanghai 200040, P.R. China

    1 shared publication
  • Qiande Liao

    Department of Orthopedics, Xiangya Hospital, Central South University, Changsha, Hunan 410078, P.R. China

    1 shared publication
  • Xiaojun Weng

    Department of Joint Surgery, Hunan Provincial People's Hospital, Changsha, Hunan 410005, P.R. China

    1 shared publication
  • Xiaosheng Li

    Department of Joint Surgery, Hunan Provincial People's Hospital, Changsha, Hunan 410005, P.R. China

    1 shared publication

Latest Publications

  • Open Access

    In vivo testing of porous Ti-25Nb alloy serving as a femoral stem prosthesis in a rabbit model

    by Xiaojun Weng, Hailin Yang, Jian Xu, Xiaosheng Li, Qiande Liao, Jing Wang

    The aim of the present study was to observe the performance of Ti-25Nb alloys with various porosities as femoral stem prostheses in a rabbit model, thus providing basic experimental evidence for the development of porous prostheses. The porous Ti-25Nb alloy prostheses were designed according to the morphology of the medullary cavity. These prostheses were placed into the femoral medullary cavities in 36 New Zealand white rabbits. Postoperative X-ray films, scanning electron microscopy (SEM) of the implant interface, energy-dispersive spectroscopy (EDS) analysis of the implant surface, pulling-out test and general observations were conducted. The specimens showed good biocompatibility; there was no obvious bone absorption in porous Ti-25Nb specimens with different porosities at different time points observed using X-ray films. Under SEM examination, calcium deposits were observed inside the pores and in the interface between bone and prostheses. The EDS analysis demonstrated that calcium deposits were present on the surface of the prostheses at the eight-week point postoperatively. The pulling-out test showed good bonding strength between bone and implant; after pulling out, the surface and inside the pores of the prostheses all presented bone mass. Porous Ti-25Nb alloy implants presents good biocompatibility as well as providing a biological fixation between the bone and implant. A porosity of 70% is more advantageous to the newborn bone ingrowth, combined with achieving a more solid bone-implant interface.