Thaysa Monteiro Ramos
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Research Interests
Thaysa Monteiro Ramos has a total of 7 co-authors. Here are the top co-authors by number of shared publications:
- Carlos de Paula Eduardo
Faculdade de Odontologia da USP (FOUSP), Universidade de São Paulo, São Paulo, Brazil
2 shared publications Marcella Esteves-Oliveira
RWTH Aachen University
2 shared publicationsPatricia Moreira de Freitas
University of São Paulo (USP)
2 shared publications- Thayanne Monteiro Ramos-Oliveira
Universidade de São Paulo, Brazil
2 shared publications Nilton Azambuja
University of São Paulo (USP)
1 shared publicationNorbert Gutknecht
RWTH Aachen University
1 shared publication
Latest Publications
- 7 May 2013
- Published by Springer Nature in Lasers in Medical Science
- Vol. 30 (1) , 17-26
Effects of Er:YAG and Er,Cr:YSGG laser irradiation on the adhesion to eroded dentin
Limited information is available regarding the adhesion to eroded dentin. This study aims to evaluate the effect of different surface treatments on eroded dentin morphology and on microtensile bond strength (μTBS) of adhesive systems to this substrate. Ninety-six extracted third molars were randomly divided into eight groups (n = 12) according to the type of surface treatment and the adhesive system: G1 = Control + Clearfil SE Bond [SE], G2 = Diamond bur [DB] + SE, G3 = Er:YAG laser (60 mJ, 2 Hz, 0.12 W, 19.3 J/ cm2) + SE, G4 = Er,Cr:YSGG laser (50 mJ, 30 Hz, 1.5 W, 4.5 J/ cm2) + SE, G5 = Control + Single Bond [SB], G6 = DB + SB, G7 = Er:YAG + SB, G8 = Er,Cr:YSGG + SB. The erosive cycling was performed by immersion in 0.05 M citric acid (pH 2.3, 10 min, 6x/day) and in supersaturated solution (pH 7.0, 1 h, between acid attacks), during 5 days. Blocks of composite were bonded to the samples according to the manufacturers' instructions. After 24 h-storage in distilled/deionized water (37 °C), stick-shaped samples were obtained and submitted to μTBS test. Each surface treatment was analyzed under scanning electron microscopy (n = 4) and the bond strength values (megapascal) were analyzed by two-way ANOVA and Tukey tests (α = 0.05). All surface treatments lead to changes on eroded dentin. G4 showed the highest bond strength mean (28.3 ± 9.2 MPa), which was statistically significant higher than all the other groups (p < 0.05). The surface treatment with Er,Cr:YSGG laser irradiation (4.5 J/cm2/50 mJ/30 Hz/140 μs) prior to bonding with a self-etching adhesive system significantly increases adhesion to eroded dentin, as compared to conventional treatment.
- 7 May 2013
- Published by Springer Nature in Lasers in Medical Science
- Vol. 30 (1) , 17-26
Effects of Er:YAG and Er,Cr:YSGG laser irradiation on the adhesion to eroded dentin
Limited information is available regarding the adhesion to eroded dentin. This study aims to evaluate the effect of different surface treatments on eroded dentin morphology and on microtensile bond strength (μTBS) of adhesive systems to this substrate. Ninety-six extracted third molars were randomly divided into eight groups (n = 12) according to the type of surface treatment and the adhesive system: G1 = Control + Clearfil SE Bond [SE], G2 = Diamond bur [DB] + SE, G3 = Er:YAG laser (60 mJ, 2 Hz, 0.12 W, 19.3 J/ cm2) + SE, G4 = Er,Cr:YSGG laser (50 mJ, 30 Hz, 1.5 W, 4.5 J/ cm2) + SE, G5 = Control + Single Bond [SB], G6 = DB + SB, G7 = Er:YAG + SB, G8 = Er,Cr:YSGG + SB. The erosive cycling was performed by immersion in 0.05 M citric acid (pH 2.3, 10 min, 6x/day) and in supersaturated solution (pH 7.0, 1 h, between acid attacks), during 5 days. Blocks of composite were bonded to the samples according to the manufacturers' instructions. After 24 h-storage in distilled/deionized water (37 °C), stick-shaped samples were obtained and submitted to μTBS test. Each surface treatment was analyzed under scanning electron microscopy (n = 4) and the bond strength values (megapascal) were analyzed by two-way ANOVA and Tukey tests (α = 0.05). All surface treatments lead to changes on eroded dentin. G4 showed the highest bond strength mean (28.3 ± 9.2 MPa), which was statistically significant higher than all the other groups (p < 0.05). The surface treatment with Er,Cr:YSGG laser irradiation (4.5 J/cm2/50 mJ/30 Hz/140 μs) prior to bonding with a self-etching adhesive system significantly increases adhesion to eroded dentin, as compared to conventional treatment.
- 26 January 2013
- Published by Springer Nature in Lasers in Medical Science
- Vol. 29 (2) , 565-573
Microtensile bond strength analysis of adhesive systems to Er:YAG and Er,Cr:YSGG laser-treated dentin
The aim of this in vitro study was to evaluate the effect of different surface treatments (control, diamond bur, erbium-doped yttrium aluminum garnet (Er:YAG) laser, and erbium, chromium:yttrium–scandium–gallium–garnet (Er,Cr:YSGG) laser) on sound dentin surface morphology and on microtensile bond strength (μTBS). Sixteen dentin fragments were randomly divided into four groups (n = 4), and different surface treatments were analyzed by scanning electron microscopy. Ninety-six third molars were randomly divided into eight groups (n = 12) according to type of surface treatment and adhesive system: G1 = Control + Clearfil SE Bond (SE); G2 = Control + Single Bond (SB); G3 = diamond bur (DB) + SE; G4 = DB + SB, G5 = Er:YAG laser (2.94 μm, 60 mJ, 2 Hz, 0.12 W, 19.3 J/cm2) + SE; G6 = Er:YAG + SB, G7 = Er,Cr:YSGG laser (2.78 μm, 50 mJ, 30 Hz, 1.5 W, 4.5 J/cm2) + SE; and G8 = Er,Cr:YSGG + SB. Composite blocks were bonded to the samples, and after 24-h storage in distilled/deionized water (37 °C), stick-shaped samples were obtained and submitted to μTBS test. Bond strength values (in megapascal) were analyzed by two-way ANOVA and Tukey tests (α = 0.05). G1 (54.69 ± 7.8 MPa) showed the highest mean, which was statistically significantly higher than all the other groups (p < 0.05). For all treatments, SE showed higher bond strength than SB, except only for Er,Cr:YSGG treatment, in which the systems did not differ statistically from each other. Based on the irradiation parameters considered in this study, it can be concluded that Er:YAG and Er,Cr:YSGG irradiation presented lower values than the control group; however, their association with self-etching adhesive does not have a significantly negative effect on sound dentin (μTBS values of >20 MPa).
- 26 January 2013
- Published by Springer Nature in Lasers in Medical Science
- Vol. 29 (2) , 565-573
Microtensile bond strength analysis of adhesive systems to Er:YAG and Er,Cr:YSGG laser-treated dentin
The aim of this in vitro study was to evaluate the effect of different surface treatments (control, diamond bur, erbium-doped yttrium aluminum garnet (Er:YAG) laser, and erbium, chromium:yttrium–scandium–gallium–garnet (Er,Cr:YSGG) laser) on sound dentin surface morphology and on microtensile bond strength (μTBS). Sixteen dentin fragments were randomly divided into four groups (n = 4), and different surface treatments were analyzed by scanning electron microscopy. Ninety-six third molars were randomly divided into eight groups (n = 12) according to type of surface treatment and adhesive system: G1 = Control + Clearfil SE Bond (SE); G2 = Control + Single Bond (SB); G3 = diamond bur (DB) + SE; G4 = DB + SB, G5 = Er:YAG laser (2.94 μm, 60 mJ, 2 Hz, 0.12 W, 19.3 J/cm2) + SE; G6 = Er:YAG + SB, G7 = Er,Cr:YSGG laser (2.78 μm, 50 mJ, 30 Hz, 1.5 W, 4.5 J/cm2) + SE; and G8 = Er,Cr:YSGG + SB. Composite blocks were bonded to the samples, and after 24-h storage in distilled/deionized water (37 °C), stick-shaped samples were obtained and submitted to μTBS test. Bond strength values (in megapascal) were analyzed by two-way ANOVA and Tukey tests (α = 0.05). G1 (54.69 ± 7.8 MPa) showed the highest mean, which was statistically significantly higher than all the other groups (p < 0.05). For all treatments, SE showed higher bond strength than SB, except only for Er,Cr:YSGG treatment, in which the systems did not differ statistically from each other. Based on the irradiation parameters considered in this study, it can be concluded that Er:YAG and Er,Cr:YSGG irradiation presented lower values than the control group; however, their association with self-etching adhesive does not have a significantly negative effect on sound dentin (μTBS values of >20 MPa).