Katarina Nikoletic
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Katarina Nikoletic has a total of 6 co-authors. Here are the top co-authors by number of shared publications:
Dolores Srbovan
Department of Nuclear Medicine, Institute of Oncology of Vojvodina, Sremska Kamenica
2 shared publicationsRadmila Zeravica
Clinical Center of Vojvodina, Department of Nuclear Medicine, Novi Sad
2 shared publicationsVioleta Kolarov
Department of General Pulmology, Institute of Pulmonary Diseases, Sremska Kamenica
2 shared publicationsAndrea Peter
Nuclear Medicine Department, Institute of Oncology of Vojvodina, Institutski put 4, Sremska Kamenica 21204, Serbia
1 shared publication- Jasna Mihailovic
Department of Nuclear Medicine, Faculty of Medicine, University of Novi Sad, Hajduk Veljkova 3, 21000 Novi Sad, Serbia
1 shared publication Silvija Lucic
Nuclear Medicine Department, Institute of Oncology of Vojvodina, Institutski put 4, Sremska Kamenica 21204, Serbia
1 shared publication
Latest Publications
- 5 February 2014
- Published by National Library of Serbia
Myocardial perfusion scintigraphy in detection of coronary artery disease
- 5 February 2014
- Published by National Library of Serbia
Myocardial perfusion scintigraphy in detection of coronary artery disease
- Open Access
- 1 January 2014
- Published by National Library of Serbia in Vojnosanitetski Pregled
- Vol. 71 (5) , 438-445
Lung tumors: Early and delayed ratio of 99mTc-methoxy-2-isobutylisonitrile accumulation
Background/Aim. Currently used radiopharmaceuticals are nonspecific and most of them are accumulated by benign tumors as well as inflammatory lesions, abscess or granulomatous lesions. Some factors such as the choice of radiopharmaceutical applied, histopathologic type of tumor, its size, location or previous tumor treatment could influence tumor imaging sensitivity. The aim of this study was to investigate accumulation of 99mTc-methoxy-2-isobutylisonitrile (99mTc- MIBI) by counting early/delayed uptake and release of this radiopharmaceutical inside lung tumors and evaluating possible factors which could be involved in its accumulation. Methods. Two-phase 99mTc-methoxy-2-isobutylisonitrile single photon emission computed tomography scan (early and delayed scan) was performed in 60 patients with lung tumors (the group 1 - 30 benign, and the group 2 - 30 malignant tumors). We calculated the uptake ratio on early (early ratio - ER), delayed images (delayed ratio - DR) and retention index (RI). Individual influence of etiology, diameter, localization, and histological type on uptake/release values was evaluated with regression analysis. Results. The values of ER and DR were significantly different in both groups (p < 0.01), showing lower values in benign vs malignant lung tumors (ER 1.36 ± 0.094 and DR 1.25 ± 0.089 vs ER = 1.93 ± 0.106 and DR = 1.7 ± 0.095 respectively). Tumor size showed a significant influence on the change of ER and DR values (p < 0.01), with greater uptake in tumors > 3 cm. RI values showed no significance between the two groups (p > 0.05). Conclusion. The uptake ratio of 99mTc-methoxy-2-isobutylisonitrile could be a useful index in differentiating lung tumors, while RI has no influence on this. Among the evaluated factors, ER and DR values are significantly influenced only by the diameter of lung tumor, while localization or different histological types between the groups has no influence on this.
- 1 January 2014
- Published by National Library of Serbia in Vojnosanitetski Pregled
- Vol. 71 (5) , 438-445
Open AccessLung tumors: Early and delayed ratio of 99mTc-methoxy-2-isobutylisonitrile accumulation
Background/Aim. Currently used radiopharmaceuticals are nonspecific and most of them are accumulated by benign tumors as well as inflammatory lesions, abscess or granulomatous lesions. Some factors such as the choice of radiopharmaceutical applied, histopathologic type of tumor, its size, location or previous tumor treatment could influence tumor imaging sensitivity. The aim of this study was to investigate accumulation of 99mTc-methoxy-2-isobutylisonitrile (99mTc- MIBI) by counting early/delayed uptake and release of this radiopharmaceutical inside lung tumors and evaluating possible factors which could be involved in its accumulation. Methods. Two-phase 99mTc-methoxy-2-isobutylisonitrile single photon emission computed tomography scan (early and delayed scan) was performed in 60 patients with lung tumors (the group 1 - 30 benign, and the group 2 - 30 malignant tumors). We calculated the uptake ratio on early (early ratio - ER), delayed images (delayed ratio - DR) and retention index (RI). Individual influence of etiology, diameter, localization, and histological type on uptake/release values was evaluated with regression analysis. Results. The values of ER and DR were significantly different in both groups (p < 0.01), showing lower values in benign vs malignant lung tumors (ER 1.36 ± 0.094 and DR 1.25 ± 0.089 vs ER = 1.93 ± 0.106 and DR = 1.7 ± 0.095 respectively). Tumor size showed a significant influence on the change of ER and DR values (p < 0.01), with greater uptake in tumors > 3 cm. RI values showed no significance between the two groups (p > 0.05). Conclusion. The uptake ratio of 99mTc-methoxy-2-isobutylisonitrile could be a useful index in differentiating lung tumors, while RI has no influence on this. Among the evaluated factors, ER and DR values are significantly influenced only by the diameter of lung tumor, while localization or different histological types between the groups has no influence on this.
- Open Access
- 20 August 2011
- Published by Association of Basic Medical Sciences of FBIH in Biomolecules and Biomedicine
- Vol. 11 (3) , 174-179
Lung 99mTc-MIBI scintigraphy: impact on diagnosis of solitary pulmonary nodule
Most of today available non-invasive procedures cannot clearly determinate between benign and malignant solitary pulmonary nodules (SPN). The purpose of the study was to assess the possibility of using 99mTc labeled hexakis-2-methoxyisobutylisonitrile (99mTc-MIBI) to differentiate benign from malignant SPN. Sixty patients were included in the study if the CT scan showed indeterminate SPN. Prior to definitive diagnosis 99mTc-MIBI single photon emission computerized tomography (SPECT) was performed: early scan 10 minutes and delayed 60-120 minutes after the intravenous injection of 740 MBq 99mTc-MIBI using dual-headed Gamma camera. The results were considered positive if there was an increased accumulation of the radiopharmaceutical in the area of the lung corresponding to the location of the lesion. The mean nodule size ± SD measured on CT scan was 2.96 cm. Lung cancer was diagnosed in 30/60 patients (14 squamocellular, 10 adenocarcinoma, 3 large-cell and 3 microcellular lung carcinomas). Of the 30 patients with malignant lesions, 27 patients (90%) had positive 99mTc-MIBI scan results by qualitative assessment. Among benign lesions, 23/30 (76.7%) were negative on 99mTc-MIBI scan. The size and PH report of SPN is statistically significantly influencing on 99mTc-MIBI accumulation in the SPN (p<0.01). The sensitivity, specificity, accuracy, positive and negative predictive value were 90%, 76.6%, 79.4%, 88.5% and 83.3% respectively. 99mTc-MIBI SPECT is an inexpensive non-invasive diagnostic procedure which might be useful diagnostic modality in the evaluation of SPN. Easy availability and low cost makes 99mTc-MIBI SPECT an attractive method in evaluating SPN.
- 20 August 2011
- Published by Association of Basic Medical Sciences of FBIH in Biomolecules and Biomedicine
- Vol. 11 (3) , 174-179
Open AccessLung 99mTc-MIBI scintigraphy: impact on diagnosis of solitary pulmonary nodule
Most of today available non-invasive procedures cannot clearly determinate between benign and malignant solitary pulmonary nodules (SPN). The purpose of the study was to assess the possibility of using 99mTc labeled hexakis-2-methoxyisobutylisonitrile (99mTc-MIBI) to differentiate benign from malignant SPN. Sixty patients were included in the study if the CT scan showed indeterminate SPN. Prior to definitive diagnosis 99mTc-MIBI single photon emission computerized tomography (SPECT) was performed: early scan 10 minutes and delayed 60-120 minutes after the intravenous injection of 740 MBq 99mTc-MIBI using dual-headed Gamma camera. The results were considered positive if there was an increased accumulation of the radiopharmaceutical in the area of the lung corresponding to the location of the lesion. The mean nodule size ± SD measured on CT scan was 2.96 cm. Lung cancer was diagnosed in 30/60 patients (14 squamocellular, 10 adenocarcinoma, 3 large-cell and 3 microcellular lung carcinomas). Of the 30 patients with malignant lesions, 27 patients (90%) had positive 99mTc-MIBI scan results by qualitative assessment. Among benign lesions, 23/30 (76.7%) were negative on 99mTc-MIBI scan. The size and PH report of SPN is statistically significantly influencing on 99mTc-MIBI accumulation in the SPN (p<0.01). The sensitivity, specificity, accuracy, positive and negative predictive value were 90%, 76.6%, 79.4%, 88.5% and 83.3% respectively. 99mTc-MIBI SPECT is an inexpensive non-invasive diagnostic procedure which might be useful diagnostic modality in the evaluation of SPN. Easy availability and low cost makes 99mTc-MIBI SPECT an attractive method in evaluating SPN.