Dandan Zhang
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Dandan Zhang has a total of 11 co-authors. Here are the top co-authors by number of shared publications:
Mengjun Wu
2 shared publicationsPeng Cao
2 shared publicationsShuping Jiang
2 shared publicationsWenliang Jin
2 shared publicationsEnlong Liu
1 shared publicationJianzhong Chen
1 shared publication
Latest Publications
- Open Access
- 6 June 2024
- Published by Elsevier in Case Studies in Thermal Engineering
- Vol. 60
Experimental study on thermal bridge effect of steel-concrete-steel tunnel elements under fireproof board insulation schemes
- 6 June 2024
- Published by Elsevier in Case Studies in Thermal Engineering
- Vol. 60
Open AccessExperimental study on thermal bridge effect of steel-concrete-steel tunnel elements under fireproof board insulation schemes
- Open Access
- 22 September 2023
- Published by Elsevier in Case Studies in Thermal Engineering
- Vol. 51
Experimental study on heat transfer rules and thermal damage of steel-concrete-steel tunnel elements in fires
- 22 September 2023
- Published by Elsevier in Case Studies in Thermal Engineering
- Vol. 51
Open AccessExperimental study on heat transfer rules and thermal damage of steel-concrete-steel tunnel elements in fires
- Open Access
- 22 July 2023
- Published by Elsevier in Case Studies in Thermal Engineering
- Vol. 49
Experimental study on fireproof board insulation technique for steel-concrete-steel immersed tunnel
- 22 July 2023
- Published by Elsevier in Case Studies in Thermal Engineering
- Vol. 49
Open AccessExperimental study on fireproof board insulation technique for steel-concrete-steel immersed tunnel
- Open Access
Fire Resistance Test and Numerical Simulation on the Tube Structure of Steel–Concrete–Steel Immersed Tube Tunnel
To provide references for the fire prevention design of steel–concrete–steel immersed tube tunnels, four types of test conditions—no fire protection, fireproof coating insulation, single-layer seam fireproof boards, and double-layer seam fireproof boards—were carried out using partial full-size structural test members. Additionally, the thermal insulation effects of various fireproofing technology solutions were contrasted and analyzed. Combined with the numerical simulation analysis, the temperature distribution law inside the tube structure under various fireproofing measures and the temperature rise law of measuring points at different depths were studied, and the protective effect of the fireproof layers on the tube structure under high fire temperature was demonstrated. The results of the numerical simulation and the experimental data agree well. The results show that adding fireproof layers can significantly lower both the steel shell’s surface temperature and the depth of fire impact. Without fire protection, the surface temperature of the bottom steel shell exceeds 300 °C at 69 s, and the member bursts. The fireproof coatings are cracked and flaking and cannot meet the fire resistance limits. Both single-seam and double-seam schemes of calcium silicate boards can meet the fire resistance limit requirements and the latter has a better heat insulation effect.
Open AccessFire Resistance Test and Numerical Simulation on the Tube Structure of Steel–Concrete–Steel Immersed Tube Tunnel
To provide references for the fire prevention design of steel–concrete–steel immersed tube tunnels, four types of test conditions—no fire protection, fireproof coating insulation, single-layer seam fireproof boards, and double-layer seam fireproof boards—were carried out using partial full-size structural test members. Additionally, the thermal insulation effects of various fireproofing technology solutions were contrasted and analyzed. Combined with the numerical simulation analysis, the temperature distribution law inside the tube structure under various fireproofing measures and the temperature rise law of measuring points at different depths were studied, and the protective effect of the fireproof layers on the tube structure under high fire temperature was demonstrated. The results of the numerical simulation and the experimental data agree well. The results show that adding fireproof layers can significantly lower both the steel shell’s surface temperature and the depth of fire impact. Without fire protection, the surface temperature of the bottom steel shell exceeds 300 °C at 69 s, and the member bursts. The fireproof coatings are cracked and flaking and cannot meet the fire resistance limits. Both single-seam and double-seam schemes of calcium silicate boards can meet the fire resistance limit requirements and the latter has a better heat insulation effect.