E. S. Selva Priya
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
E. S. Selva Priya has a total of 4 co-authors. Here are the top co-authors by number of shared publications:
L. Suganthi
2 shared publications- L. Suganthi
Sri Sivasubramaniya Nadar College of Engineering
1 shared publication R. Anandha Praba
SSN College of Engineering, OMR Road
1 shared publicationR. Jeyashree
Meenakshi College of Engineering
1 shared publication
Latest Publications
- 22 July 2023
- Published by Elsevier in Integration
- Vol. 93
Design and implementation of low power Advanced Encryption Standard cryptocore utilizing dynamic pipelined asynchronous model
- 22 July 2023
- Published by Elsevier in Integration
- Vol. 93
Design and implementation of low power Advanced Encryption Standard cryptocore utilizing dynamic pipelined asynchronous model
- Open Access
- 8 March 2023
- Published by Springer Nature in Research Square
Low Power FPGA Implementation of an Efficient AES- SBOX Realization for Health Care Applications
In present digital world, the data transmitted over network has become worldwide. The information compiled, processed and communicated in Bits and bytes of digital format over communication channels. For secure communication an advanced encryption Standard (AES) cryptographic algorithm is employed to avoid the risk of secret information tampering. This Research article predominantly focuses on low power and low area hardware architecture designed using Field Programmable Gate array. The novel architecture is derived by employing composite field arithmetic for substitute byte and inverse substitute bytes operation. By this approach the unwanted delay occurs during the Look up table (LUT) method has been averted. Optimized Positive polarity reed Muller (OPPRM) architecture is introduced in order to minimize the hardware utilization, eventually subpipeling technique has brought in, to enhance the speed of the architecture. The Performance metrics of OPPRM-AES is evaluated with respect to Bonded IPADS, Slice, LUTS, Number of slices, Static as well as Dynamic Power. The performance of a proposed architecture is compared with AES-PPRM, AES-CFA and AES-ECG.The architecture is implemented onto Zynq ZC702 Evaluation Board and the simulation is performed through the vivado 2019.1 software.
- 8 March 2023
- Published by Springer Nature in Research Square
Open AccessLow Power FPGA Implementation of an Efficient AES- SBOX Realization for Health Care Applications
In present digital world, the data transmitted over network has become worldwide. The information compiled, processed and communicated in Bits and bytes of digital format over communication channels. For secure communication an advanced encryption Standard (AES) cryptographic algorithm is employed to avoid the risk of secret information tampering. This Research article predominantly focuses on low power and low area hardware architecture designed using Field Programmable Gate array. The novel architecture is derived by employing composite field arithmetic for substitute byte and inverse substitute bytes operation. By this approach the unwanted delay occurs during the Look up table (LUT) method has been averted. Optimized Positive polarity reed Muller (OPPRM) architecture is introduced in order to minimize the hardware utilization, eventually subpipeling technique has brought in, to enhance the speed of the architecture. The Performance metrics of OPPRM-AES is evaluated with respect to Bonded IPADS, Slice, LUTS, Number of slices, Static as well as Dynamic Power. The performance of a proposed architecture is compared with AES-PPRM, AES-CFA and AES-ECG.The architecture is implemented onto Zynq ZC702 Evaluation Board and the simulation is performed through the vivado 2019.1 software.
- 2 August 2022
- Published by Springer Nature
- p. 569-584
Assessment of Cardiovascular System Through Cardiovascular Autonomic Reflex Test
- 2 August 2022
- Published by Springer Nature
- p. 569-584
Assessment of Cardiovascular System Through Cardiovascular Autonomic Reflex Test