    MRI Safety Considerations for Permanent Magnet Implants in Muscle

    by Cameron R. Taylor, Eric D. Anttila, Steven J. Charlebois, David C. Gross, Amanda F. Taylor, Jose O. Negron‐Garcia, Christopher E. Suckow, L. Tiffany Lyle, Scott R. Hooten, Seong Ho Yeon, et al.

    Background: Permanent magnet implants are used with several medical and assistive devices, such as cochlear implants, dental attachments, and prosthetic control, but raise caution for MR imaging. Previous work has evaluated several magnet implants for position and magnetization stability, as well as for image artifacts under MRI. Yet, the intramuscular magnets used for prosthetic control still require evaluation for potential MRI conditionality. Purpose: To investigate the position and magnetization stability of and image artifacts from 3‐mm‐diameter spherical permanent magnets ( B r = 1.393 T, H ci = 1.637 MA/m) implanted within muscle. Study Type: Prospective longitudinal study. Animal Model: Porcine; one animal, eight muscles. Field Strength/Sequence: 0.55‐T, 1.5‐T/SE, GRE. Assessment: Permanent magnets and nonmagnetic controls were implanted into eight muscles and exposed to 1.5‐T MRI 36 days post‐implantation. All sites were examined histologically for evidence of implant migration (acute fibrotic response or fibrotic capsule disruption). Benchtop studies evaluated worst‐case demagnetization and image artifacts (artifact radius minus implant radius). The primary measure of position stability was histological examination interpreting characteristics of progressive skeletal muscle healing. Secondary position stability analysis was performed via CT imaging. Statistical Tests: Unpaired one‐sided sign test with a significance level of 0.05. Demagnetization and imaging artifacts were summarized as maximums. Results: Fibrotic capsules were similarly intact at permanent magnet and control sites (fibrotic capsule thicknesses: 20–550 μm [magnets], 20–220 μm [controls]). No effect of MRI exposure on implant migration was observed via secondary analysis ( p = 0.965 [0.55‐T], p = 0.996 [1.5‐T]). Maximum demagnetization was 2.1% under 0.55‐T exposure and 13.5% under 1.5‐T exposure, and maximum image artifact was 71 mm at both imaging strengths. Data Conclusion: The permanent magnet implants used in this study were resistant to migration and substantial demagnetization under 0.55‐T and 1.5‐T MRI exposure and resulted in negligible image artifacts for critical organ imaging, suggesting that the presence of these implants does not preclude a patient from receiving MR imaging up to 1.5T. Evidence Level: N/A. Technical Efficacy: Stage 5: Improvements in patient care.


  • Open Access

    Feasibility of magnetic resonance imaging-guided cardiac catheterization, angioplasty, and stenting in a commercial wide-bore 0.55T scanner

    by Aimee K. Armstrong, Yixuan Liu, John M. Kelly, Ramkumar Krishnamurthy, Jason Swinning, Yingmin Liu, Matthew Joseph, Ning Jin, Jianing Pang, Florian Maier, et al.


  • Open Access

    Computational modeling of the thermal effects of flow on radio frequency-induced heating of peripheral vascular stents during MRI

    by David C Gross, Benjamin W Scandling, Alan R. Leewood, Orlando P Simonetti

    Purpose. The goal of this study was to develop and validate a computational model that can accurately predict the influence of flow on the temperature rise near a peripheral vascular stent during magnetic resonance imaging (MRI). Methods. Computational modeling and simulation of radio frequency (RF) induced heating of a vascular stent during MRI at 3.0 T was developed and validated with flow phantom experiments. The maximum temperature rise of the stent was measured as a function of physiologically relevant flow rates. Results. A significant difference was not identified between the experiment and simulation (P > 0.05). The temperature rise of the stent during MRI was over 10 °C without flow, and was reduced by 5 °C with a flow rate of only 58 ml min−1, corresponding to a reduction of CEM43 from 45 min to less than 1 min. Conclusion. The computer model developed in this study was validated with experimental measurements, and accurately predicted the influence of flow on the RF-induced temperature rise of a vascular stent during MRI. Furthermore, the results of this study demonstrate that relatively low flow rates significantly reduce the temperature rise of a stent and the surrounding medium during RF-induced heating under typical scanning power and physiologically relevant conditions.


  • Magnetic Susceptibility of Common Metals and Alloys Used in Medical Devices

    by Adam J. Griebel, Eric Anttila, Grant Baker, Jeremy E. Schaffer, David C. Gross

    Magnetic resonance imaging (MRI) is a widely used imaging modality that is ideally suited for imaging soft tissues. The use of strong magnetic and electric fields employed in MRI creates the potential for hazards when imaging patients with metallic implants. With the proper material selection, implant design, and imaging procedure, many of these hazards can be adequately managed. Magnetic susceptibility (χ) is a material property indicating a material’s tendency to interact with and distort an applied magnetic field, and it has substantial influence on both the force and torque experienced by an implant in a magnetic field, as well as the size of the image artifact. In this study, the magnetic susceptibilities of 45 different medically relevant alloys and alloy composites are determined and reported. This data will aid in material selection for medical devices intended to be labeled as MR Conditional.