David C. Gross
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
David C. Gross has a total of 38 co-authors. Here are the top co-authors by number of shared publications:
Eric D. Anttila
MED Institute West Lafayette Indiana USA
2 shared publications- Orlando P. Simonetti
Department of Radiology, The Ohio State University, Columbus, Ohio, USA
2 shared publications - Adam J. Griebel
Fort Wayne Metals
1 shared publication - Aimee K. Armstrong
The Heart Center, Nationwide Children's Hospital, Columbus, Ohio
1 shared publication Alan R. Leewood
MED Institute Inc, 1330 Win Hentschel Blvd, West Lafayette, West Lafayette, Indiana, 47906-5394, UNITED STATES
1 shared publication- Alessandro Alan Porporati
CeramTec GmbH
1 shared publication
Latest Publications
- Open Access
- 17 September 2025
- Published by Wiley in Journal of Magnetic Resonance Imaging
- Vol. 63 (2) , 563-573
MRI Safety Considerations for Permanent Magnet Implants in Muscle
Background: Permanent magnet implants are used with several medical and assistive devices, such as cochlear implants, dental attachments, and prosthetic control, but raise caution for MR imaging. Previous work has evaluated several magnet implants for position and magnetization stability, as well as for image artifacts under MRI. Yet, the intramuscular magnets used for prosthetic control still require evaluation for potential MRI conditionality. Purpose: To investigate the position and magnetization stability of and image artifacts from 3‐mm‐diameter spherical permanent magnets ( B r = 1.393 T, H ci = 1.637 MA/m) implanted within muscle. Study Type: Prospective longitudinal study. Animal Model: Porcine; one animal, eight muscles. Field Strength/Sequence: 0.55‐T, 1.5‐T/SE, GRE. Assessment: Permanent magnets and nonmagnetic controls were implanted into eight muscles and exposed to 1.5‐T MRI 36 days post‐implantation. All sites were examined histologically for evidence of implant migration (acute fibrotic response or fibrotic capsule disruption). Benchtop studies evaluated worst‐case demagnetization and image artifacts (artifact radius minus implant radius). The primary measure of position stability was histological examination interpreting characteristics of progressive skeletal muscle healing. Secondary position stability analysis was performed via CT imaging. Statistical Tests: Unpaired one‐sided sign test with a significance level of 0.05. Demagnetization and imaging artifacts were summarized as maximums. Results: Fibrotic capsules were similarly intact at permanent magnet and control sites (fibrotic capsule thicknesses: 20–550 μm [magnets], 20–220 μm [controls]). No effect of MRI exposure on implant migration was observed via secondary analysis ( p = 0.965 [0.55‐T], p = 0.996 [1.5‐T]). Maximum demagnetization was 2.1% under 0.55‐T exposure and 13.5% under 1.5‐T exposure, and maximum image artifact was 71 mm at both imaging strengths. Data Conclusion: The permanent magnet implants used in this study were resistant to migration and substantial demagnetization under 0.55‐T and 1.5‐T MRI exposure and resulted in negligible image artifacts for critical organ imaging, suggesting that the presence of these implants does not preclude a patient from receiving MR imaging up to 1.5T. Evidence Level: N/A. Technical Efficacy: Stage 5: Improvements in patient care.
- 17 September 2025
- Published by Wiley in Journal of Magnetic Resonance Imaging
- Vol. 63 (2) , 563-573
Open AccessMRI Safety Considerations for Permanent Magnet Implants in Muscle
Background: Permanent magnet implants are used with several medical and assistive devices, such as cochlear implants, dental attachments, and prosthetic control, but raise caution for MR imaging. Previous work has evaluated several magnet implants for position and magnetization stability, as well as for image artifacts under MRI. Yet, the intramuscular magnets used for prosthetic control still require evaluation for potential MRI conditionality. Purpose: To investigate the position and magnetization stability of and image artifacts from 3‐mm‐diameter spherical permanent magnets ( B r = 1.393 T, H ci = 1.637 MA/m) implanted within muscle. Study Type: Prospective longitudinal study. Animal Model: Porcine; one animal, eight muscles. Field Strength/Sequence: 0.55‐T, 1.5‐T/SE, GRE. Assessment: Permanent magnets and nonmagnetic controls were implanted into eight muscles and exposed to 1.5‐T MRI 36 days post‐implantation. All sites were examined histologically for evidence of implant migration (acute fibrotic response or fibrotic capsule disruption). Benchtop studies evaluated worst‐case demagnetization and image artifacts (artifact radius minus implant radius). The primary measure of position stability was histological examination interpreting characteristics of progressive skeletal muscle healing. Secondary position stability analysis was performed via CT imaging. Statistical Tests: Unpaired one‐sided sign test with a significance level of 0.05. Demagnetization and imaging artifacts were summarized as maximums. Results: Fibrotic capsules were similarly intact at permanent magnet and control sites (fibrotic capsule thicknesses: 20–550 μm [magnets], 20–220 μm [controls]). No effect of MRI exposure on implant migration was observed via secondary analysis ( p = 0.965 [0.55‐T], p = 0.996 [1.5‐T]). Maximum demagnetization was 2.1% under 0.55‐T exposure and 13.5% under 1.5‐T exposure, and maximum image artifact was 71 mm at both imaging strengths. Data Conclusion: The permanent magnet implants used in this study were resistant to migration and substantial demagnetization under 0.55‐T and 1.5‐T MRI exposure and resulted in negligible image artifacts for critical organ imaging, suggesting that the presence of these implants does not preclude a patient from receiving MR imaging up to 1.5T. Evidence Level: N/A. Technical Efficacy: Stage 5: Improvements in patient care.
- Open Access
- 10 February 2025
- Published by Elsevier in Journal of Cardiovascular Magnetic Resonance
- Vol. 27 (1) , 101858
Feasibility of magnetic resonance imaging-guided cardiac catheterization, angioplasty, and stenting in a commercial wide-bore 0.55T scanner
- 10 February 2025
- Published by Elsevier in Journal of Cardiovascular Magnetic Resonance
- Vol. 27 (1) , 101858
Open AccessFeasibility of magnetic resonance imaging-guided cardiac catheterization, angioplasty, and stenting in a commercial wide-bore 0.55T scanner
- Open Access
- 26 October 2023
- Published by IOP Publishing in Biomedical Physics & Engineering Express
- Vol. 9 (6) , 065025
Computational modeling of the thermal effects of flow on radio frequency-induced heating of peripheral vascular stents during MRI
Purpose. The goal of this study was to develop and validate a computational model that can accurately predict the influence of flow on the temperature rise near a peripheral vascular stent during magnetic resonance imaging (MRI). Methods. Computational modeling and simulation of radio frequency (RF) induced heating of a vascular stent during MRI at 3.0 T was developed and validated with flow phantom experiments. The maximum temperature rise of the stent was measured as a function of physiologically relevant flow rates. Results. A significant difference was not identified between the experiment and simulation (P > 0.05). The temperature rise of the stent during MRI was over 10 °C without flow, and was reduced by 5 °C with a flow rate of only 58 ml min−1, corresponding to a reduction of CEM43 from 45 min to less than 1 min. Conclusion. The computer model developed in this study was validated with experimental measurements, and accurately predicted the influence of flow on the RF-induced temperature rise of a vascular stent during MRI. Furthermore, the results of this study demonstrate that relatively low flow rates significantly reduce the temperature rise of a stent and the surrounding medium during RF-induced heating under typical scanning power and physiologically relevant conditions.
- 26 October 2023
- Published by IOP Publishing in Biomedical Physics & Engineering Express
- Vol. 9 (6) , 065025
Open AccessComputational modeling of the thermal effects of flow on radio frequency-induced heating of peripheral vascular stents during MRI
Purpose. The goal of this study was to develop and validate a computational model that can accurately predict the influence of flow on the temperature rise near a peripheral vascular stent during magnetic resonance imaging (MRI). Methods. Computational modeling and simulation of radio frequency (RF) induced heating of a vascular stent during MRI at 3.0 T was developed and validated with flow phantom experiments. The maximum temperature rise of the stent was measured as a function of physiologically relevant flow rates. Results. A significant difference was not identified between the experiment and simulation (P > 0.05). The temperature rise of the stent during MRI was over 10 °C without flow, and was reduced by 5 °C with a flow rate of only 58 ml min−1, corresponding to a reduction of CEM43 from 45 min to less than 1 min. Conclusion. The computer model developed in this study was validated with experimental measurements, and accurately predicted the influence of flow on the RF-induced temperature rise of a vascular stent during MRI. Furthermore, the results of this study demonstrate that relatively low flow rates significantly reduce the temperature rise of a stent and the surrounding medium during RF-induced heating under typical scanning power and physiologically relevant conditions.
- Open Access
- 23 July 2023
- Published by Elsevier in Arthroplasty Today
- Vol. 22, 101170
Magnetic Resonance Safety Evaluation of a Novel Alumina Matrix Composite Ceramic Knee and Image Artifact Comparison to a Metal Knee Implant of Analogous Design
- 23 July 2023
- Published by Elsevier in Arthroplasty Today
- Vol. 22, 101170
Open AccessMagnetic Resonance Safety Evaluation of a Novel Alumina Matrix Composite Ceramic Knee and Image Artifact Comparison to a Metal Knee Implant of Analogous Design
- 16 May 2023
- Published by ASTM International in Journal of Testing and Evaluation
- Vol. 51 (6) , 4554-4566
Magnetic Susceptibility of Common Metals and Alloys Used in Medical Devices
Magnetic resonance imaging (MRI) is a widely used imaging modality that is ideally suited for imaging soft tissues. The use of strong magnetic and electric fields employed in MRI creates the potential for hazards when imaging patients with metallic implants. With the proper material selection, implant design, and imaging procedure, many of these hazards can be adequately managed. Magnetic susceptibility (χ) is a material property indicating a material’s tendency to interact with and distort an applied magnetic field, and it has substantial influence on both the force and torque experienced by an implant in a magnetic field, as well as the size of the image artifact. In this study, the magnetic susceptibilities of 45 different medically relevant alloys and alloy composites are determined and reported. This data will aid in material selection for medical devices intended to be labeled as MR Conditional.
- 16 May 2023
- Published by ASTM International in Journal of Testing and Evaluation
- Vol. 51 (6) , 4554-4566
Magnetic Susceptibility of Common Metals and Alloys Used in Medical Devices
Magnetic resonance imaging (MRI) is a widely used imaging modality that is ideally suited for imaging soft tissues. The use of strong magnetic and electric fields employed in MRI creates the potential for hazards when imaging patients with metallic implants. With the proper material selection, implant design, and imaging procedure, many of these hazards can be adequately managed. Magnetic susceptibility (χ) is a material property indicating a material’s tendency to interact with and distort an applied magnetic field, and it has substantial influence on both the force and torque experienced by an implant in a magnetic field, as well as the size of the image artifact. In this study, the magnetic susceptibilities of 45 different medically relevant alloys and alloy composites are determined and reported. This data will aid in material selection for medical devices intended to be labeled as MR Conditional.