CACihan Asci

Cihan Asci

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Cihan Asci has a total of 22 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    A Bioelectrochemical Crossbar Architecture Screening Platform (BiCASP) for Extracellular Electron Transfer

    by Hasika Suresh, Presley Bird, Kundan Saha, Surya Varchasvi Devaraj, Cihan Asci, Albert Truong, Cooper Wallman, Rhea Shailesh Patel, Atul Sharma, Matthew D. Carpenter, et al.

    Summary: Electroactive microbes can be used as components in electrical devices to leverage their unique behavior for biotechnology, but they remain challenging to engineer because the bioelectrochemical systems (BES) used for characterization are low-throughput. To overcome this challenge, we describe the development of the Bioelectrochemical Crossbar Architecture Screening Platform (BiCASP), which allows for samples to be arrayed and characterized in individually addressable microwells. This device reliably reports on the current generated by electroactive bacteria on the minute time scale, decreasing the time for data acquisition by several orders of magnitude compared to conventional BES. Also, this device increased the throughput of screening engineered biological components in cells, quickly identifying mutants of the membrane protein wire MtrA in Shewanella oneidensis that retain the ability to support extracellular electron transfer (EET). BiCASP is expected to enable the design of new components for bioelectronics by supporting directed evolution of electroactive proteins. The bigger picture: Devices that interface microbes and materials, known as bioelectronics, can be used to sense environmental chemicals in real time, generate energy from sugars, and synthesize chemicals. While these devices leverage the unique capabilities of living systems as components in devices, such as their ability to convert chemical information in the environment into electrical information at the cell surface, it remains challenging to engineer these cellular components and their biomolecules for new applications, largely because commercially available bioelectrochemical systems for monitoring current generated by electroactive microbes are costly and require large culture volumes, needs continuous monitoring for days to obtain stable signals, and multichannel potentiostats to monitor multiple microbes in parallel. To overcome these challenges, we created the Bioelectrochemical Crossbar Architecture Screening Platform or BiCASP that is easy to fabricate, enables parallel analysis of microbial samples in flexible arrayed formats, and yields a stable signal on the minute time scale. This device is expected to enable the application of combinatorial protein engineering methods, such as directed evolution, to proteins that control microbial current production, by allowing for fast screening of cells expressing protein mutant libraries. As a proof-of-concept, we demonstrate that this device can screen for cells that express mutants of decaheme cytochromes that retain the ability to electrically connect cells to electrodes. This device will simplify the engineering of cells and proteins that function as electrical switches as well as the diversification of bioelectronic devices for real-time sensing of chemicals in the environment. Furthermore, BiCASP is promising as a high-throughput screening (HTS) platform, enabling rapid, parallel analysis of cellular and molecular interactions of diverse biological systems through label-free electrochemical methods. Such capabilities could transform drug discovery, personalized medicine, and functional genomics, supporting systematic genetic and chemical screens even at single-cell resolution. Highlights: A high-throughput screening platform with individual addressability A device with a flexible crossbar architecture that simplifies current analysis Reproducible detection of real-time cellular current on the minute time scale The device can be used to screen a library for cells with functional protein wires Graphical

  • Ingestible pH sensing device for gastrointestinal health monitoring based on thread-based electrochemical sensors

    by Cihan Asci, Atul Sharma, Ruben Del-Rio-Ruiz, Sameer Sonkusale

    There exists a strong correlation between the pH levels of the gastrointestinal (GI) tract and GI diseases such as inflammatory bowel disease (IBS), ulcerative colitis, and pancreatis. Existing methods for diagnosing many GI diseases predominantly rely on invasive, expensive, and time-consuming techniques such as colonoscopy and endoscopy. In this study, an autonomous ingestible smart biosensing system in a pill format with integrated pH sensors is reported. The smart sensing pills will measure the pH profile as they transit through the GI tract. The data is then downloaded from the pills after they are collected from the feces. The sensor is based on electrodeposited PANI on carbon-coated conductive threads providing high pH sensitivity. Engineering innovations allowed integration of thread-based sensors on 3D-printed pill surfaces with front-end readout electronics, memory, and microcontroller assembled on mm-size circular printed circuit boards. The entire smart sensing pill possesses an overall length of 22.1 mm and an outer diameter of 9 mm. The modular biosensing system allows integration of thread-based biosensors to monitor other biomarkers in GI tract that mitigates the complex sensor fabrication process as well as overall pill assembly.


  • Multiplexed Sensing Probe for Bioreactors for Cellular Agriculture

    by Atul Sharma, Cihan Asci, Ruben Del-Rio-Ruiz, Kirsten Trinidad, Nafize Ishtiaque Hossain, David L. Kaplan, Sameer Sonkusale

    A portable scalable multiplexed thread-based sensing microprobe for continuous monitoring of pH and ammonium ions during the bio-fermentation process is demonstrated. Continuous real-time monitoring can facilitate active intervention to improve cell growth in a bioreactor to help maintain phenotype. Each sensing microprobe consists of a 3D-printed shell (length 14.2 mm, outer diameter 9 mm) to hold separate working and reference electrode threads about 1.0 mm in length. Inlets and outlets facilitate continuous flow during monitoring. The functionality of the constructed microprobe was evaluated in a simulated micro-reactor with different pH, temp, and ion concentrations that resembles a fermentation environment. The sensitivity and selectivity of sensors were evaluated, and results indicate promising dynamic range for pH (2.86 to 7.81) and ammonium (10 $\mu$M to 100 mM) for bioreactor monitoring.


  • Open Access

    A frequency-adjustable helical antenna using shape memory alloy

    by Wei Wang, Cihan Asci, Wenxin Zeng, Rachel Owyeung, Sameer Sonkusale

    There is a need to develop low-cost and compact frequency reconfigurable antennas with continuous frequency tuning capability. Existing approaches rely on dedicated electrical, mechanical, or MEMS-based approaches to reconfigure the antenna, which requires extra components and fabrication steps. In this paper, we propose a physics-based approach to realize tunable helical antennas based on a shape memory alloy (SMA). By utilizing the temperature-induced irreversible mechanical deformation of the SMA, the temperature-controlled antenna can continuously change its resonant frequency and lock the state when the desired frequency response is achieved. The height of the helical antenna changes in response to applied temperatures. No additional circuitry or mechanical modules are required for the reconfiguration of the antenna geometry. The fabricated helical antenna can shift resonant frequency between 150 and 195 MHz with a tuning sensitivity of 284 kHz/°C.


  • Security Monitoring System Using Magnetically-Activated RFID Tags

    by Cihan Asci, Wei Wang, Sameer Sonkusale

    Existing methods for home security monitoring depend on expensive custom battery-powered solutions. In this article, we present a battery-free solution that leverages any off-the-shelf passive radio frequency identification (RFID) tag for real-time entry detection. Sensor consists of a printed RFID antenna on paper, coupled to a magnetic reed switch and is affixed on the door. Opening of the door triggers the reed switch causing RFID signal transmission detected by any off-the-shelf passive RFID reader. This paper shows simulation and experimental results for such magnetically-actuated RFID (or magRFID) opening sensor.


  • Open Access

    Design and implementation of magnetically–tunable quad–band filter utilizing split–ring resonators at microwave frequencies

    by Cihan Asci, Aydin Sadeqi, Wei Wang, Hojatollah Rezaei Nejad, Sameer Sonkusale

    In this article, we present a magnetically–tunable quad–band filter with high tunability in the frequency range of 2.1–3.9 GHz. A multi–band filter with four stop–bands comprises of a microstrip line coupled to four frequency–selective split–ring resonators (SRRs). We achieve tuning of individual frequency bands using magnetic reed switches connected in between the capacitive gaps of each split–ring resonator. Application of magnetic field tunes this capacitance affecting its resonance frequency. The measured reflection spectrum of the proposed device matches well with the simulation results. The results show more than 25% tunability for each of the four bands with bandwidth values in the range of 30–70 MHz with over 100% overall tunability in the 2.1–3.9 GHz frequency spectrum.