Béla Bodó
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Béla Bodó has a total of 5 co-authors. Here are the top co-authors by number of shared publications:
- Baizhan Li
Joint International Research Laboratory of Green Buildings and Built Environments (Ministry of Education), Chongqing University, Chongqing 400045, China
1 shared publication - Emese Béni
Department of Building Services and Building Engineering, Faculty of Engineering, University of Debrecen, H-4028 Debrecen, Hungary
1 shared publication - Ferenc Kalmár
Department of Building Services and Building Engineering, Faculty of Engineering, University of Debrecen, Ótemető str. 2-4, 4028 Debrecen, Hungary
1 shared publication - Gábor L. Szabó
Department of Building Services and Building Engineering, Faculty of Engineering, University of Debrecen, H-4028 Debrecen, Hungary
1 shared publication - Tünde Kalmár
Department of Building Services and Building Engineering, Faculty of Engineering, University of Debrecen, Ótemető str. 2-4, 4028 Debrecen, Hungary
1 shared publication
Latest Publications
- Open Access
Decarbonization Potential of Energy Used in Detached Houses—Case Study
The main objectives of this study were the energy assessment of detached houses built in different periods in a central European city. A total of 236 detached houses built between 1930 and 2023 in Debrecen (Hungary) were analyzed from an energy perspective, and their CO2 emissions were measured. It was found that the net floor area of family houses built in recent years has increased but that the compactness of buildings has increased as well. The specific heat loss coefficient and the specific energy demand for heating in new buildings have decreased to 15.2% and 18.5%, respectively, over the last 90 years. Furthermore, around one third of the analyzed buildings built several decades ago must have already been renovated at least once for energy efficiency, as their heat demands are 27.6–41.4% lower than estimated. Energy consumption in six houses built in recent years was measured and studied. It was found that the occupants’ behavior may increase CO2 emissions from heating by 26%, while CO2 emissions from hot-water preparation may decrease by 38.2%. The potential of the locally available sources of renewable energy was calculated, and the costs of decarbonization packages for eight building groups were evaluated.
Open AccessDecarbonization Potential of Energy Used in Detached Houses—Case Study
The main objectives of this study were the energy assessment of detached houses built in different periods in a central European city. A total of 236 detached houses built between 1930 and 2023 in Debrecen (Hungary) were analyzed from an energy perspective, and their CO2 emissions were measured. It was found that the net floor area of family houses built in recent years has increased but that the compactness of buildings has increased as well. The specific heat loss coefficient and the specific energy demand for heating in new buildings have decreased to 15.2% and 18.5%, respectively, over the last 90 years. Furthermore, around one third of the analyzed buildings built several decades ago must have already been renovated at least once for energy efficiency, as their heat demands are 27.6–41.4% lower than estimated. Energy consumption in six houses built in recent years was measured and studied. It was found that the occupants’ behavior may increase CO2 emissions from heating by 26%, while CO2 emissions from hot-water preparation may decrease by 38.2%. The potential of the locally available sources of renewable energy was calculated, and the costs of decarbonization packages for eight building groups were evaluated.
- Open Access
A Facility’s Energy Demand Analysis for Different Building Functions
A more accurate determination of energy demands for buildings is of utmost importance for estimating future energy demands. This article presents two novel ideas that have the potential to contribute to a more precise determination of expected energy demands. The first idea involves accounting for a building’s function more thoroughly, which enables the determination of different energy demands for two or more identical buildings, depending on their respective usage functions. According to a case study, the heating energy demand can be up to twice as high in a commercial facility compared with a residential building. Similarly, the cooling energy requirement can also differ. The second idea concerns determining the heating degree day (HDD) and cooling degree day (CDD) values from the daily minimum and maximum temperatures. This idea may be relevant when few instantaneous values are available for the daily mean temperature. According to the case study, the calculated values from the daily minimum and maximum temperatures follow the HDD and CDD values specified from the daily mean temperature. However, the difference is less than 2% for the heating season and higher for the cooling season. Therefore, further research is required to refine the constants in the cooling equation.
Open AccessA Facility’s Energy Demand Analysis for Different Building Functions
A more accurate determination of energy demands for buildings is of utmost importance for estimating future energy demands. This article presents two novel ideas that have the potential to contribute to a more precise determination of expected energy demands. The first idea involves accounting for a building’s function more thoroughly, which enables the determination of different energy demands for two or more identical buildings, depending on their respective usage functions. According to a case study, the heating energy demand can be up to twice as high in a commercial facility compared with a residential building. Similarly, the cooling energy requirement can also differ. The second idea concerns determining the heating degree day (HDD) and cooling degree day (CDD) values from the daily minimum and maximum temperatures. This idea may be relevant when few instantaneous values are available for the daily mean temperature. According to the case study, the calculated values from the daily minimum and maximum temperatures follow the HDD and CDD values specified from the daily mean temperature. However, the difference is less than 2% for the heating season and higher for the cooling season. Therefore, further research is required to refine the constants in the cooling equation.