ZWZhaoxin Wang

Zhaoxin Wang

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Zhaoxin Wang has a total of 40 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • A Thermal Modeling Method for Power Capacitors Under Long Timescale Dynamic Operation Profiles

    by Bo Yao, Xing Wei, Zhaoxin Wang, Yichi Zhang, Huimin Wang, Xinglai Ge, Haoran Wang, Lei Qi, Huai Wang

  • Discharge Profile-Based Converter-Level Health Monitoring for Power Semiconductor Module in Traction Inverter Application

    by Xing Wei, Zhaoxin Wang, Bo Yao, Shuai Zhao, Yingzhou Peng, Huai Wang

    This paper proposes a converter-level health monitoring scheme for power semiconductor modules in traction inverter applications, implemented via the standard inverter DC-link discharge operation mode after system shutdown. The on-state voltage information of all power devices in the inverter is acquired in combined forms from the inverter three-phase output terminals, minimizing invasiveness to the traction inverter while reducing implementation costs due to fewer sensor requirements. By leveraging the low-dynamic features of discharge operation, data acquisition remains robust under relaxed sampling conditions and immune to parasitic parameter interference, further reducing monitoring complexity and uncertainty. To enable effective decision-making in field operation, the operating and environmental variables affecting the acquired on-state voltage combinations are identified, and a degradation model-based data calibration scheme is provided to process historical raw data. Based on this monitoring scheme, proactive maintenance for the power module in traction inverters can be scheduled prior to failure, thereby enhancing system availability and reducing maintenance costs. Proof-of-concept experiments are conducted to verify its effectiveness and feasibility for practical application.

  • A Converter-Level Health Monitoring Method for Traction Inverter Application

    by Xing Wei, Zhaoxin Wang, Bo Yao, Yingzhou Peng, Yongchao Sun, Kai Wang, Huai Wang

    This article proposes a converter-level health monitoring method for detecting critical degradation in either dc-link capacitors or power semiconductor modules in traction inverters. The outcome can be used for condition-based maintenance decisions to determine whether the inverter or its power stage as a whole needs to be replaced. The proposed method is based on the dc-link voltage profile during the capacitor discharge operation mode after a traction system is already shut down, which is a standard operation mode for safety reasons. Therefore, the method relies only on existing resources from traction inverters without the need for additional hardware or software. The theoretical foundation of the method and practical considerations for implementation are discussed. Proof-of-concept experiments are performed to validate its effectiveness and feasibility for practical application.


  • A Robust Health Monitoring Method for DC-Link Capacitor Banks in Aerospace Motor Drives

    by Xing Wei, Bo Yao, Zhaoxin Wang, Yingzhou Peng, Bastien Granouillac, Kepa Odriozola, Huai Wang, Amir Sajjad Bahman

    This article presents a health monitoring scheme for dc-link capacitor banks in aerospace motor drives, implemented through the standard postlanding discharge operation of the motor drive. The capacitance percentage of the dc-link capacitor bank relative to its healthy baseline is directly evaluated using solely the dc-link voltage profile without additional hardware upgrades or complex computations, minimizing cost and complexity concerns. Furthermore, to ensure monitoring reliability and effectiveness, practical implementation solutions are provided to address challenges arising from varying operating conditions and unbalanced capacitor degradation within the bank. Compared with existing methods, the proposed scheme offers superior practical deployability and operational robustness. Experimental validation through component-level accelerated aging tests and converter-level discharge tests demonstrates capacitance percentage evaluation error within 0.6%, and reliable detection of critical degradation in individual capacitors within the dc-link capacitor bank under varying operating conditions, enabling proactive maintenance before failure occurs.


  • Partial Discharge Behavior of High-Frequency Transformer Insulation Under High-Voltage PWM Stress

    by Zhaoxin Wang, Xing Wei, Claus Leth Bak, Filipe Faria da Silva, Tianming Luo, Weichuan Zhao, Peter Vaessen, Henrik Sørensen, Mohamad Ghaffarian Niasar

    As the voltage levels of solid-state transformers (SSTs) increase using medium-voltage switches, high-frequency transformers (HFTs) used inside SSTs are subjected to increased electrical stress. This stress, characterized by high voltage, high-frequency pulsewidth modulation (PWM) voltage, can cause insulation partial discharge (PD) and potentially lead to failure of the HFT insulation system. While PD behavior under power-frequency sinusoidal voltage has been extensively studied, the behavior of HFT insulation under PWM square pulse conditions is less well understood. To address this gap, a high voltage high-frequency PWM voltage PD test platform is developed and high-frequency current transformer (HFCT) and ultra-high-frequency (UHF) antenna are used for PD signal detection. PD tests are performed under a variety of PWM conditions including PWM frequency, rise time, voltage amplitude, and different insulation layers to thoroughly investigate the HFT insulation behavior. The PD characteristics of repetitive PD inception voltage and phase-resolved PD patterns at different PWM conditions are recorded and analyzed under PWM conditions. In addition, this article explores the underlying PD mechanisms of the HFT insulation under high-frequency PWM stress, providing insights to explain the observed test results. The findings from this research provide essential references and lay a solid foundation for future advances in optimal design, health monitoring, reliability analysis, and lifetime prediction for HFTs in power electronics applications.


  • Open Access

    Finite Element Analysis of Electromagnetic Characteristics of a Single-Phase Permanent Magnet Linear Oscillation Actuator

    by Hongbin Zhang, Zhaoxin Wang, Minshuo Chen, Zhan Shen, Haitao Yu, Zhike Xu

    The electromagnetic characteristics of a single-phase permanent magnet linear oscillation actuator are analyzed by the finite element method. Firstly, the basic structure and operation principle of the linear oscillation actuator are introduced. The internal stator slot and arc tooth are used to reduce the detent force. According to the principle of electromagnetic fields, the electromagnetic field equation is listed and the function of the motor is deduced. At the same time, the eight-node hexahedral element is used to calculate the listed universal functions, and the inductance, flux linkage, induced electromotive force and electromagnetic force of the motor are deduced. The electromagnetic field of the motor is simulated by two-dimensional and three-dimensional finite element methods, and the accuracy of the calculation results of the electromagnetic characteristics of the cylindrical linear oscillation motor by the two methods is compared and analyzed. Finally, an experimental prototype was developed and the no-load characteristics of the motor were tested using the existing linear motor towing method. By comparing the experimental and simulation results, the accuracy of the theoretical analysis and the rationality of the motor design are verified.


  • Interactions Analysis and Life Modeling for High-Frequency Transformers Insulation Under Multistress

    by Zhaoxin Wang, Xing Wei, Filipe Faria da Silva, Henrik Sørensen, Zhan Shen, Claus Leth Bak

    High-frequency transformers (HFTs) are key devices in solid-state transformers (SSTs). Accurate prediction of the remaining life of the HFT is essential to ensure the reliability of the SST. The insulation of the HFT withstands multistress of high-frequency pulsewidth modulation (PWM) voltage, and high temperature. These severe conditions may lead to its accelerated aging and failure. However, the life characteristics of the HFT insulation subjected to multistress of high voltage, high frequency, and high temperature are not well known introducing a big uncertainty for life prediction and reliability assessment of the HFT, and there is a lack of life model that can be used for HFT insulation considering multistress. This article focuses on the investigation of the interaction between multistress of high voltage, high frequency, and high temperature and it proposes a life model applicable to HFT insulation. A high-frequency PWM voltage electrothermal aging test platform is established, which is capable of generating PWM voltage waveforms up to 10 kV and 100 kHz. The electrothermal aging test is designed and analyzed with the response surface method and analysis of variance. The results revealed a significant effect of switching frequency on the insulation life and non-negligible interactions among the three factors, voltage level, switching frequency, and temperature, at high frequencies. Based on these findings, an electro-thermal-frequency life model for HFT insulation is proposed. Finally, the mechanism of insulation aging and breakdown mechanism at high frequencies is analyzed, and the potential application of the proposed life model is discussed. The outcomes of this research offer valuable references and serve as the foundation for predictive maintenance, insulation system design, and reliability analysis of HFTs under multistress.


  • A Robust Online Junction Temperature Calibration Method for Power Semiconductors in Traction Inverter Application

    by Xing Wei, Bo Yao, Zhaoxin Wang, Yi Zhang, Yingzhou Peng, Yongchao Sun, Kai Wang, Huai Wang

    Thermo-sensitive electrical parameters (TSEPs) are widely used for estimating the junction temperature of power semiconductors, with the prerequisite that the relationship model between junction temperature and TSEPs is precalibrated. This article proposes an innovative online calibration scheme for power semiconductors in traction inverters, utilizing the inverter dc-link discharge operation mode after system shutdown. It is promising for transportation applications like electric vehicles (EVs) as the required operation mode is intrinsic and frequent. By exploiting the low dynamics in the discharge, the challenges in junction temperature acquisition are addressed and the measurement requirements for TSEPs and associated operation conditions are significantly reduced. The disturbances from parasitic parameters are attenuated as well, enabling calibration accuracy comparable to offline calibration. Compared to existing online calibration schemes, the proposed method outperforms in practicality, complexity, and accuracy, allowing robust calibration in traction applications. The on-state saturation voltage of insulated-gate bipolar transistor (IGBT) devices is used as a typical TSEP for the case study, and proof-of-concept experiments are performed on an automotive traction inverter prototype.


  • Multiphysics Digital Model of the High Frequency Transformer for Power Electronics Application Considering Electro-Thermal Interactions

    by Zhaoxin Wang, Claus Leth Bak, Huai Wang, Henrik Sørensen, Filipe Faria da Silva

    The high frequency transformer (HFT) applied in the power electronics operate under the combined stresses of high-frequency PWM voltage and high temperature. The electro-thermal coupling effect can accelerate the aging process and even cause the failure of the HFT's insulation. The accurate modeling and simulation of the multiphysics fields of the HFT is crucial for investigating the electrical and thermal stresses on the insulation. The interaction between the electromagnetic and temperature fields in HFTs makes this task challenging. Specifically, the temperature field in HFTs is influenced by electromagnetic losses, while the electromagnetic parameters of the material and loss distribution are related to temperature and voltage frequency. This paper explores the interaction between high-frequency electromagnetic and temperature fields and develops a comprehensive multiphysics coupling model based on the analyzed results. The model allows for the digital replicate of the circuit, electric, magnetic and temperature fields and it provides precise identification of the electrical and thermal stresses on the insulation. A 60 kHz HFT for dual active bridge (DAB) applications is taken as the example and the simulation results indicate that the proposed model can improve accuracy by 19.14% compared to conventional methods. Finally, a high-frequency pulse width modulation (PWM) test platform for the HFT is developed, and the proposed model is validated through experimental results.


  • Performance evaluation and quantitative study of the hyperspectral lidar prototype for offshore oil pollution monitoring

    by Jing Li, Shu Li, Yannan Zhai, Shuang Luan, Zhaoxin Wang, Yankun Tang, Meishan Jin

    The high spectral lidar principled sample machine that can obtain the target spectral information as well as the twodimensional images was developed from the perspective of motoring the marine oil spill pollution in this thesis, this high spectral lidar principled sample machine can cover the wavelength range from 400nm to 1100nm. And this high spectral lidar principled sample machine was applied for the remote sensing detection of vegetation, oceans, minerals and some other ground object targets, through measuring the spectral radiance of the hyperspectral laser interacting with the target and returning to the lidar receiving system, so as to realize the real-time monitoring of vegetation, oceans and minerals. For the purpose of realizing the quantitative observation, an accurate radiometric calibration on high spectral lidar was required. The radiometric calibration of high spectral lidar was aimed at its receiving system, that was to determine the responsivity of the principled sample machine to the target spectral radiance. After finishing debugging, all the indicators of the principled sample machine can meet the application requirements, which provided a new monitoring means for the marine oil spill in our country and was of great significance for the future protection of marine environment and the application and exploitation of marine resources.