Pouria Amani
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Pouria Amani has a total of 14 co-authors. Here are the top co-authors by number of shared publications:
- Jaber Safdari
Materials and Nuclear Fuel Research School, Nuclear Science and Technology Research Institute, Tehran, Iran
4 shared publications Mohammad H. Mallah
3 shared publicationsFarhad Panahinia
Nuclear Fuel Cycle Research School, Nuclear Science and Technology Research Institute, Tehran, Iran
2 shared publicationsJaber Safdari
2 shared publicationsMohammad Ghannadi-Maragheh
Nuclear Fuel Cycle Research School, Nuclear Science and Technology Research Institute, Tehran, Iran
2 shared publications- Mohammad Hassan Mallah
Materials and Nuclear Fuel Research School, Nuclear Science and Technology Research Institute, Tehran, Iran
2 shared publications
Latest Publications
- 1 December 2017
- Published by Elsevier in Chemical Engineering Research and Design
- Vol. 128, 130-145
Investigation of mass transfer performance in an L-shaped pulsed sieve plate extraction column using axial dispersion model
- 1 December 2017
- Published by Elsevier in Chemical Engineering Research and Design
- Vol. 128, 130-145
Investigation of mass transfer performance in an L-shaped pulsed sieve plate extraction column using axial dispersion model
- 2 October 2017
- Published by Taylor & Francis in Separation Science and Technology
- Vol. 52 (17) , 2742-2755
Experimental investigation on the mean drop size and drop size distribution in an L-shaped pulsed sieve-plate column
Vertical pulsed extraction columns cannot be employed in applications with height limitations. On the other hand, the horizontal extraction columns have low throughput, which affects their applicability in industrial applications. Therefore, there is a need to design a new type of extractors for such circumstances. In this paper, an experimental study on drop sizes has been implemented in a novel L-shaped pulsed sieve-plate extraction column in the absence and presence of mass transfer. Moreover, new correlations are developed for prediction of the mean drop size and size distribution using the log-normal probability density function.
- 2 October 2017
- Published by Taylor & Francis in Separation Science and Technology
- Vol. 52 (17) , 2742-2755
Experimental investigation on the mean drop size and drop size distribution in an L-shaped pulsed sieve-plate column
Vertical pulsed extraction columns cannot be employed in applications with height limitations. On the other hand, the horizontal extraction columns have low throughput, which affects their applicability in industrial applications. Therefore, there is a need to design a new type of extractors for such circumstances. In this paper, an experimental study on drop sizes has been implemented in a novel L-shaped pulsed sieve-plate extraction column in the absence and presence of mass transfer. Moreover, new correlations are developed for prediction of the mean drop size and size distribution using the log-normal probability density function.
- 1 June 2017
- Published by Elsevier in International Journal of Heat and Fluid Flow
- Vol. 65, 266-276
Two-phase pressure drop and flooding characteristics in a horizontal-vertical pulsed sieve-plate column
- 1 June 2017
- Published by Elsevier in International Journal of Heat and Fluid Flow
- Vol. 65, 266-276
Two-phase pressure drop and flooding characteristics in a horizontal-vertical pulsed sieve-plate column
- 16 February 2017
- Published by Taylor & Francis in Separation Science and Technology
- p. 1-16
Modeling and simulation of a horizontal pulsed sieve-plate extraction column using axial dispersion model
In this research, the impact of pulsation intensity and phase flow rates on the volumetric overall mass transfer coefficients based on the continuous phase (Koca) and the axial dispersion coefficients of phases in a horizontal pulsed sieve-plate column has been investigated using axial dispersion model. The toluene-acetone-water and butyl acetate-acetone-water systems with acetone transfer in both directions were used. In this study, the flow regime transition from pseudo-dispersion regime to emulsion regime has been characterized. Two new correlations have been proposed for prediction of Koca and Ec.
- 16 February 2017
- Published by Taylor & Francis in Separation Science and Technology
- p. 1-16
Modeling and simulation of a horizontal pulsed sieve-plate extraction column using axial dispersion model
In this research, the impact of pulsation intensity and phase flow rates on the volumetric overall mass transfer coefficients based on the continuous phase (Koca) and the axial dispersion coefficients of phases in a horizontal pulsed sieve-plate column has been investigated using axial dispersion model. The toluene-acetone-water and butyl acetate-acetone-water systems with acetone transfer in both directions were used. In this study, the flow regime transition from pseudo-dispersion regime to emulsion regime has been characterized. Two new correlations have been proposed for prediction of Koca and Ec.
- Open Access
- 30 January 2017
- Published by Royal Society of Chemistry (RSC) in RSC Advances
- Vol. 7 (15) , 8908-8921
Experimental investigation concerning the effect of mass transfer direction on mean drop size and holdup in a horizontal pulsed plate extraction column
Vertical extraction columns meet the needs of industrial applications, but when height limitation (especially in indoor applications) is a concern it is required to use horizontal columns. Considering the significant role of mass transfer in the sizing and scale-up of horizontal extraction columns, no analytical and experimental investigations have been conducted in this regard. In the present research, the effect of operating parameters including pulsation intensity and phase flow rates on the mean drop size and the dispersed phase holdup values was investigated in a horizontal pulsed sieve-plate column under both mass transfer directions for the toluene–acetone–water, n-butyl acetate–acetone–water and butanol–acetone–water systems. The results show that holdup decreases first and then increases with an increase of pulsation intensity. Increasing dispersed phase velocity also increases holdup. The mean drop size decreases with an increment of pulsation intensity, whereas flow rates of both phases have little impact. Moreover, it is observed that the presence of mass transfer significantly affects the mean drop size and holdup. Finally, new correlations were proposed for the prediction of mean drop size and holdup based on operating variables and physical properties of the systems with and without mass transfer. Average Absolute Relative Error (AARE) of the correlations was between about 6.83–15.38% for their optimized constants.
- 30 January 2017
- Published by Royal Society of Chemistry (RSC) in RSC Advances
- Vol. 7 (15) , 8908-8921
Open AccessExperimental investigation concerning the effect of mass transfer direction on mean drop size and holdup in a horizontal pulsed plate extraction column
Vertical extraction columns meet the needs of industrial applications, but when height limitation (especially in indoor applications) is a concern it is required to use horizontal columns. Considering the significant role of mass transfer in the sizing and scale-up of horizontal extraction columns, no analytical and experimental investigations have been conducted in this regard. In the present research, the effect of operating parameters including pulsation intensity and phase flow rates on the mean drop size and the dispersed phase holdup values was investigated in a horizontal pulsed sieve-plate column under both mass transfer directions for the toluene–acetone–water, n-butyl acetate–acetone–water and butanol–acetone–water systems. The results show that holdup decreases first and then increases with an increase of pulsation intensity. Increasing dispersed phase velocity also increases holdup. The mean drop size decreases with an increment of pulsation intensity, whereas flow rates of both phases have little impact. Moreover, it is observed that the presence of mass transfer significantly affects the mean drop size and holdup. Finally, new correlations were proposed for the prediction of mean drop size and holdup based on operating variables and physical properties of the systems with and without mass transfer. Average Absolute Relative Error (AARE) of the correlations was between about 6.83–15.38% for their optimized constants.
- Open Access
- 12 January 2017
- Published by Royal Society of Chemistry (RSC) in RSC Advances
- Vol. 7 (4) , 2288-2300
Experimental investigation on regime transition and characteristic velocity in a horizontal–vertical pulsed sieve-plate column
In this study, we attempted to evaluate the flow regime transitions in a novel type of extractor, called a horizontal–vertical pulsed sieve-plate column, for three liquid–liquid systems: toluene–water, butyl acetate–water, and n-butanol–water, with a 3% volumetric fraction of acetone in the dispersed phase as a mass transfer agent. Moreover, due to the importance of the characteristic velocity, the effects of operating parameters, such as the pulsation intensity and flow rate of the phases, have been investigated in each section of the column. The characteristic velocity shows different behaviors with the variation of the operating parameters in each section, which has been thoroughly discussed in this study. New correlations for the transitions from the mixer-settler regime to the dispersion regime in the vertical section and from the dispersion regime to the emulsion regime in the horizontal section have been proposed, which indicate the lower and upper limits of the proper pulsation intensity to identify the operational range of the dispersion regime. Furthermore, new correlations have been proposed for the prediction of the characteristic velocity in each section of the column, with average absolute relative errors (AAREs) ranging from 9.81% to 11.15%, which represent a satisfactory agreement between the experimental and calculated data.
- 12 January 2017
- Published by Royal Society of Chemistry (RSC) in RSC Advances
- Vol. 7 (4) , 2288-2300
Open AccessExperimental investigation on regime transition and characteristic velocity in a horizontal–vertical pulsed sieve-plate column
In this study, we attempted to evaluate the flow regime transitions in a novel type of extractor, called a horizontal–vertical pulsed sieve-plate column, for three liquid–liquid systems: toluene–water, butyl acetate–water, and n-butanol–water, with a 3% volumetric fraction of acetone in the dispersed phase as a mass transfer agent. Moreover, due to the importance of the characteristic velocity, the effects of operating parameters, such as the pulsation intensity and flow rate of the phases, have been investigated in each section of the column. The characteristic velocity shows different behaviors with the variation of the operating parameters in each section, which has been thoroughly discussed in this study. New correlations for the transitions from the mixer-settler regime to the dispersion regime in the vertical section and from the dispersion regime to the emulsion regime in the horizontal section have been proposed, which indicate the lower and upper limits of the proper pulsation intensity to identify the operational range of the dispersion regime. Furthermore, new correlations have been proposed for the prediction of the characteristic velocity in each section of the column, with average absolute relative errors (AAREs) ranging from 9.81% to 11.15%, which represent a satisfactory agreement between the experimental and calculated data.