SXSherman Xuegang Xin

Sherman Xuegang Xin

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Sherman Xuegang Xin has a total of 28 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Variation in the dielectric properties of freshly excised colorectal cancerous tissues at different tumor stages

    by Zhou Li, Weiwei Wang, Zhai Cai, Shuai Han, Shiming Lin, Linyun He, Miaoliang Chen, Dongyue Pan, Guanhua Deng, Song Duan, et al.

    The study was designed to identify differences in the dielectric properties of ex vivo colorectal cancerous tissues at different tumor stages. To date, 130 freshly excised colorectal cancerous specimens underwent measurement of both relative permittivity and conductivity on the serosal and mucosal surfaces of the carcinoma nidus, and the mucosa of the surgical resection margin ranging from 50 to 500 MHz at the Larmor frequencies. Tumor node metastasis staging was determined according to pathological reports for each patient. There were statistically significant differences in the relative permittivity of both colorectal cancerous serosa and mucosa among stages ≤I, II, III, and IV and between stages ≤II and ≥III (P < 0.05) at most frequencies under 300 MHz; statistically significant differences in conductivity were also observed for most of the measured frequencies (P < 0.05). The significant differences in dielectric characteristics among tumor stages, especially between early and advanced stages, have value for selecting appropriate surgical strategies. The presented ex vivo data provide important information for magnetic resonance electrical properties tomography in vivo system because the frequencies of 64 MHz (1.5T) and 128 MHz (3T) are usually used in clinical settings. Bioelectromagnetics. 38:522–532, 2017.


  • Obtaining source current density related to irregularly structured electromagnetic target field inside human body using hybrid inverse/FDTD method

    by Jijun Han, Deqiang Yang, Houjun Sun, Sherman Xuegang Xin

    Inverse method is inherently suitable for calculating the distribution of source current density related with an irregularly structured electromagnetic target field. However, the present form of inverse method cannot calculate complex field–tissue interactions. A novel hybrid inverse/finite-difference time domain (FDTD) method that can calculate the complex field–tissue interactions for the inverse design of source current density related with an irregularly structured electromagnetic target field is proposed. A Huygens’ equivalent surface is established as a bridge to combine the inverse and FDTD method. Distribution of the radiofrequency (RF) magnetic field on the Huygens’ equivalent surface is obtained using the FDTD method by considering the complex field–tissue interactions within the human body model. The obtained magnetic field distributed on the Huygens’ equivalent surface is regarded as the next target. The current density on the designated source surface is derived using the inverse method. The homogeneity of target magnetic field and specific energy absorption rate are calculated to verify the proposed method.

  • A large‐scale measurement of dielectric properties of normal and malignant colorectal tissues obtained from cancer surgeries at Larmor frequencies

    by Zhou Li, Guanhua Deng, Zhe Li, Sherman Xuegang Xin, Song Duan, Maoying Lan, Sa Zhang, Yixin Gao, Jun He, Songtao Zhang, et al.

    Purpose: Knowledge of dielectric properties of malignant human tissues is necessary for the recently developed magnetic resonance (MR) technique called MR electrical property tomography. This technique may be used in early tumor detection based on the obvious differentiation of the dielectric properties between normal and malignant tissues. However, the dielectric properties of malignant human tissues in the scale of the Larmor frequencies are not completely available in the literature. In this study, the authors focused only on the dielectric properties of colorectal tumor tissue.Methods: The dielectric properties of 504 colorectal malignant samples excised from 85 patients in the scale of the Larmor frequencies were measured using the precision open‐ended coaxial probe method. The obtained complex‐permittivity data were fitted to the single‐pole Cole–Cole model.Results: The median permittivity and conductivity for the malignant tissue sample were 79.3 and 0.881 S/m at 128 MHz, which were 14.6% and 17.0% higher, respectively, than those of normal tissue samples. Significant differences between normal and malignant tissues were found for the dielectric properties (p < 0.05).Conclusions: Experimental results indicated that the dielectric properties were significantly different between normal and malignant tissues for colorectal tissue. This large‐scale clinical measurement provides more subtle base data to validate the technique of MR electrical property tomography.


  • Potential for high‐permittivity materials to reduce local SAR at a pacemaker lead tip during MRI of the head with a body transmit coil at 3 T

    by Zidan Yu, Xuegang Xin, Christopher M. Collins

    Purpose To illustrate the potential for high permittivity materials to be used in decreasing peak local SAR associated with implants when the imaging region is far from the implant. Methods We performed numerical simulations of a human subject with a pacemaker in a body‐sized birdcage coil driven at 128 MHz with and without a thin (5 mm) shell of material of high electric permittivity around the head. Results For a shell with relative permittivity of 600, the maximum specific energy absorption rate averaged over any 1 g of tissue near the pacemaker was reduced by 73.5% for a given B1 field strength at the center of the brain. Conclusion Although further study is required, initial simulations indicate that strategic use of high permittivity materials may broaden the conditions under which patients with certain implants can be imaged safely. Magn Reson Med 78:383–386, 2017. © 2016 International Society for Magnetic Resonance in Medicine


  • Quantitative analysis of the reconstruction errors of the currently popular algorithm of magnetic resonance electrical property tomography at the interfaces of adjacent tissues

    by Song Duan, Chao Xu, Guanhua Deng, Jiajia Wang, Feng Liu, Sherman Xuegang Xin

    This work quantitatively analyzed the reconstruction errors (REs) of electrical property (EP) images using a currently popular algorithm of magnetic resonance electrical property tomography (MREPT), which occurred along the tissue interfaces. Transmitted magnetic fields were acquired at 3 T using a birdcage coil loaded with a phantom consisting of various adjacent tissues. Homogeneous Helmholtz was employed to calculate the EP maps by Laplacian computation of central differences. The maps of absolute REs (aREs) and relative REs (rREs) were calculated. The maximum and mean rREs, in addition to rRE distributions at the interfaces, were presented. Reconstructed EP maps showed various REs along different interface boundaries. Among all the investigated tissue interfaces, the kidney–fat interface presented the maximum mean rREs for both conductivity and relative permittivity. The minimum mean rRE of conductivity was observed at the spleen–muscle interface, and the minimum mean rRE of relative permittivity was detected along the lung–heart interface. The mean rREs ranged from 0.3986 to 36.11 for conductivity and 0.2218 to 11.96 for relative permittivity. Overall, this research indicates that different REs occur at various tissue boundaries, as shown by the currently popular algorithm of MREPT. Thus, REs should be considered when applying MREPT to reconstruct the EP distributions inside the human body. Copyright © 2016 John Wiley & Sons, Ltd.