XHXiao Hu

Xiao Hu

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Xiao Hu has a total of 4 co-authors. Here are the top co-authors by number of shared publications:

  • Dong Liu

    College of Energy and Power Engineering, North China University of Water Resources and Electric Power, Zhengzhou 450045, China

    1 shared publication
  • Jingjing Zhang

    College of Energy and Power Engineering, North China University of Water Resources and Electric Power, Zhengzhou 450045, China

    1 shared publication
  • Lihong Zhang

    College of Energy and Power Engineering, North China University of Water Resources and Electric Power, Zhengzhou 450045, China

    1 shared publication
  • Xinxu Wei

    College of Energy and Power Engineering, North China University of Water Resources and Electric Power, Zhengzhou 450045, China

    1 shared publication

Latest Publications

  • Open Access

    A Parameter Sensitivity Analysis of Hydropower Units under Full Operating Conditions Considering Turbine Nonlinearity

    by Dong Liu, Xinxu Wei, Jingjing Zhang, Xiao Hu, Lihong Zhang

    A parameter sensitivity analysis is an important part of the stability study of hydro turbine regulation systems, which helps operators to deepen their understanding of the characteristics and connections among the various parts of these systems. Considering that large hydropower stations undertake an essential regulation task in the power grid, the safety and stability of their operation cannot be ignored. To this end, taking a unit in a giant hydropower station in China as an example, a hydraulic–mechanical–electrical coupling model of the hydraulic turbine regulation system is established. A comprehensive parameter sensitivity indicator and parameter sensitivity analysis framework are proposed. On this basis, the sensitivity of the main system variables to parameter changes under full operating conditions is investigated by considering two different control modes of the unit (i.e., corresponding to different grid types). The results show that the sensitivity of the system state to the mechanical parameters of the generator is the highest in the power control mode, while the sensitivity to the electrical parameters of the generator and excitation system is higher in the frequency control mode. The sensitivity of the system with these key parameters also shows different patterns of change with a change in the unit operating conditions. The relevant findings can provide some theoretical guidance for the operation of hydropower stations and help to reduce the risk of system instability.