Hsin-Hui Kuo
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Hsin-Hui Kuo has a total of 16 co-authors. Here are the top co-authors by number of shared publications:
- Bai-Hung Huang
Graduate Institute of Dental Science, College of Dentistry, China Medical University, Taichung 404, Taiwan
2 shared publications - Chung-Ming Liu
Department of Biomedical Engineering, College of Biomedical Engineering, China Medical University, Taichung 404, Taiwan
2 shared publications - Hsin-Yu Tsai
School of Dental Technology, College of Oral Medicine, Taipei Medical University, Taipei 110, Taiwan
2 shared publications - Wen-Chien Lan
Department of Oral Hygiene Care, Ching Kuo Institute of Management and Health, Keelung 203, Taiwan
2 shared publications - Yung-Chieh Cho
School of Dentistry, College of Oral Medicine, Taipei Medical University, Taipei 110, Taiwan
2 shared publications - Brian Chen
Department of Biochemistry, Lehigh University, Bethlehem, PA 18015, USA
1 shared publication
Latest Publications
- Open Access
An Innovative Design to Enhance Osteoinductive Efficacy and Biomechanical Behavior of a Titanium Dental Implant
The present study investigated the in vivo bone-forming efficacy of an innovative titanium (Ti) dental implant combined with a collagen sponge containing recombinant human bone morphogenetic protein-2 (BMP-2) in a pig model. Two different concentrations of BMP-2 (20 and 40 µg/mL) were incorporated into collagen sponges and placed at the bottom of Ti dental implants. The investigated implants were inserted into the edentulous ridge at the canine–premolar regions of Lanyu small-ear pigs, which were then euthanized at weeks 1, 2, 4, 8, and 12 post-implantation. Specimens containing the implants and surrounding bone tissue were collected for histological evaluation of their bone-to-implant contact (BIC) ratios and calculation of maximum torques using removal torque measurement. Analytical results showed that the control and BMP-2-loaded implants presented good implant stability and bone healing for all testing durations. After 1 week of healing, the BMP-2-loaded implants with a concentration of 20 µg/mL exhibited the highest BIC ratios, ranging from 58% to 76%, among all groups (p = 0.034). Additionally, they also possessed the highest removal torque values (50.1 ± 1.3 N-cm) throughout the 8-week healing period. The BMP-2-loaded implants not only displayed excellent in vivo biocompatibility but also presented superior osteoinductive performance. Therefore, these findings demonstrate that BMP-2 delivered through a collagen sponge can potentially enhance the early-stage osseointegration of Ti dental implants.
Open AccessAn Innovative Design to Enhance Osteoinductive Efficacy and Biomechanical Behavior of a Titanium Dental Implant
The present study investigated the in vivo bone-forming efficacy of an innovative titanium (Ti) dental implant combined with a collagen sponge containing recombinant human bone morphogenetic protein-2 (BMP-2) in a pig model. Two different concentrations of BMP-2 (20 and 40 µg/mL) were incorporated into collagen sponges and placed at the bottom of Ti dental implants. The investigated implants were inserted into the edentulous ridge at the canine–premolar regions of Lanyu small-ear pigs, which were then euthanized at weeks 1, 2, 4, 8, and 12 post-implantation. Specimens containing the implants and surrounding bone tissue were collected for histological evaluation of their bone-to-implant contact (BIC) ratios and calculation of maximum torques using removal torque measurement. Analytical results showed that the control and BMP-2-loaded implants presented good implant stability and bone healing for all testing durations. After 1 week of healing, the BMP-2-loaded implants with a concentration of 20 µg/mL exhibited the highest BIC ratios, ranging from 58% to 76%, among all groups (p = 0.034). Additionally, they also possessed the highest removal torque values (50.1 ± 1.3 N-cm) throughout the 8-week healing period. The BMP-2-loaded implants not only displayed excellent in vivo biocompatibility but also presented superior osteoinductive performance. Therefore, these findings demonstrate that BMP-2 delivered through a collagen sponge can potentially enhance the early-stage osseointegration of Ti dental implants.
- Open Access
An Innovative Biofunctional Composite Hydrogel with Enhanced Printability, Rheological Properties, and Structural Integrity for Cell Scaffold Applications
The present study was conducted to manipulate various biomaterials to find potential hydrogel formulations through three-dimensional (3D) bioprinting fabrication for tissue repair, reconstruction, or regeneration. The hydrogels were prepared using sodium alginate and gelatin combined with different concentrations of Pluronic F127 (6% (3 g), 8% (4 g), and 10% (5 g)) and were marked as AGF-6%, AGF-8%, and AGF-10%, respectively. The properties of the hydrogels were investigated using a contact angle goniometer, rheometer, and 3D bioprinter. In addition, the osteoblast-like cell line (MG-63) was used to evaluate the cell viability including hydrogels before and after 3D bioprinting. It was found that the ratio of contact angle was lowest at AGF-6%, and the rheological results were higher for all samples of AGF-6%, AGF-8%, and AGF-10% compared with the control sample. The printability indicated that the AGF-6% hydrogel possessed great potential in creating a cell scaffold with shape integrity. Moreover, the live/dead assay also presented the highest numbers of live cells before printing compared with after printing. However, the number of live cells on day 7 was higher than on day 1 before and after printing (** p < 0.01). Therefore, the combination of AGF-6% could be developed as a biofunctional hydrogel formulation for potential tissue regeneration applications.
Open AccessAn Innovative Biofunctional Composite Hydrogel with Enhanced Printability, Rheological Properties, and Structural Integrity for Cell Scaffold Applications
The present study was conducted to manipulate various biomaterials to find potential hydrogel formulations through three-dimensional (3D) bioprinting fabrication for tissue repair, reconstruction, or regeneration. The hydrogels were prepared using sodium alginate and gelatin combined with different concentrations of Pluronic F127 (6% (3 g), 8% (4 g), and 10% (5 g)) and were marked as AGF-6%, AGF-8%, and AGF-10%, respectively. The properties of the hydrogels were investigated using a contact angle goniometer, rheometer, and 3D bioprinter. In addition, the osteoblast-like cell line (MG-63) was used to evaluate the cell viability including hydrogels before and after 3D bioprinting. It was found that the ratio of contact angle was lowest at AGF-6%, and the rheological results were higher for all samples of AGF-6%, AGF-8%, and AGF-10% compared with the control sample. The printability indicated that the AGF-6% hydrogel possessed great potential in creating a cell scaffold with shape integrity. Moreover, the live/dead assay also presented the highest numbers of live cells before printing compared with after printing. However, the number of live cells on day 7 was higher than on day 1 before and after printing (** p < 0.01). Therefore, the combination of AGF-6% could be developed as a biofunctional hydrogel formulation for potential tissue regeneration applications.