BKBl Kou

Bl Kou

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Bl Kou has a total of 4 co-authors. Here are the top co-authors by number of shared publications:

  • H Li

    Arthritis Clinic and Research Center, Peking University People's Hospital, Beijing, No.11 Xizhimen South Street, Xicheng District, Beijing, 100044, China

    1 shared publication
  • Jh Lin

    Arthritis Clinic and Research Center, Peking University People's Hospital, Beijing, No.11 Xizhimen South Street, Xicheng District, Beijing, 100044, China

    1 shared publication
  • Shuna Zhang

    Department of Physical Education and Health, Guangxi Normal University, Guilin, China

    1 shared publication
  • Xm Wang

    Orthopaedic Department, Beijing Moslem Hospital, Beijing, 100054, China

    1 shared publication

Latest Publications

  • Open Access

    Medium-term results of ceramic-on-polyethylene Zweymüller-Plus total hip arthroplasty

    by H Li, S Zhang, Xm Wang, Jh Lin, Bl Kou

    The need for better durability and longevity in total hip arthroplasty for patients with various hip joint diseases remains a challenge. This study aimed to obtain medium-term results at a follow-up of >10 years for Zweymüller-Plus total hip arthroplasty with ceramic-on-polyethylene bearing. A retrospective study was conducted to review the results after a minimum of 12.4 years of 207 consecutive total hip arthroplasties in 185 patients in Peking University People's Hospital in China using the Zweymüller SL-Plus stem in combination with the Bicon-Plus threaded cup and ceramic-on-polyethylene bearing between October 1994 and April 2000. During the study period, two patients (2 hips) died and 25 patients (28 hips) were lost to follow-up. Two hips were revised for aseptic loosening of the Bicon-Plus cup. The mean clinical and radiological follow-up was 14.1 years (range, 12.4-16.5 years) for the remaining 156 patients (175 hips). The mean (standard deviation) Harris Hip score for the 175 hips increased significantly from 39.3 (3.8) preoperatively to 94.1 (2.5) postoperatively at a mean follow-up of 14.1 years (P<0.05). Focal osteolysis was observed in seven (4.0%) of 175 stems and three (1.7%) of 175 cups. The Kaplan-Meier survival with revision for any reason as the end-point was 99.03% (95% confidence interval, 95%-100%). The high survival rate of the cementless Zweymüller-Plus system with ceramic-on-polyethylene bearing at mid-term follow-up makes this total hip arthroplasty system reliable for patients with various hip joint diseases.