Masahiko Shibuya
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Masahiko Shibuya has a total of 52 co-authors. Here are the top co-authors by number of shared publications:
- Geng-Hua Yi
CRF, Orangeburg, New York, USA
4 shared publications Gerard B. Conditt
4 shared publicationsGreg L. Kaluza
4 shared publications- Juan F. Granada
Cardiovascular Research Foundation
4 shared publications Yanping Cheng
CRF Skirball Center for Innovation, Cardiovascular Research Foundation, Orangeburg, NY, USA
4 shared publicationsKevin Van Bladel
3 shared publications
Latest Publications
- 1 December 2016
- Published by Elsevier in Journal of Cardiology Cases
- Vol. 14 (6) , 164-167
Recurrent coronary artery dissection of left main trunk initially presented with normal coronary angiography
- 1 December 2016
- Published by Elsevier in Journal of Cardiology Cases
- Vol. 14 (6) , 164-167
Recurrent coronary artery dissection of left main trunk initially presented with normal coronary angiography
- 1 April 2015
- Published by Europa Digital & Publishing in EuroIntervention
- Vol. 10 (12) , 1480-1487
Early feasibility evaluation of thoracoscopically assisted transcatheter ventricular reconstruction in an experimental model of ischaemic heart failure with left anteroapical aneurysm
To test the feasibility of a thoracoscopically assisted, off-pump, transcatheter ventricular reconstruction (TCVR) approach in an ovine model of left ventricular (LV) anteroapical aneurysm. Myocardial infarction (MI) was induced by coil occlusion of the middle left anterior descending artery and diagonals. Two months after MI creation, TCVR was performed via a minimal thoracotomy in eight sheep. Under endoscopic and fluoroscopic guidance, trans-interventricular septal puncture was performed from the LV epicardial scar. A guidewire was externalised via a snare placed in the right ventricle from the external jugular vein. An internal anchor was inserted over the wire and positioned on the right ventricular septum and an external anchor was deployed on the LV anterior epicardium. Serial pairs of anchors were placed and plicated together to exclude the scar completely. Immediately after TCVR, echocardiography showed LV end-systolic volume decreased from pre-procedure 58.8±16.6 ml to 25.1±7.6 ml (p<0.01) and the ejection fraction increased from 32.0±7.3% to 52.0±7.5% (p<0.01). LV twist significantly improved (3.83±2.21 vs. pre-procedure -0.41±0.94, p=0.01) and the global peak-systolic longitudinal strain increased from -5.64% to -10.77% (p<0.05). TCVR using minimally invasive access techniques on the off-pump beating heart is feasible and resulted in significant improvement in LV performance.
- 1 April 2015
- Published by Europa Digital & Publishing in EuroIntervention
- Vol. 10 (12) , 1480-1487
Early feasibility evaluation of thoracoscopically assisted transcatheter ventricular reconstruction in an experimental model of ischaemic heart failure with left anteroapical aneurysm
To test the feasibility of a thoracoscopically assisted, off-pump, transcatheter ventricular reconstruction (TCVR) approach in an ovine model of left ventricular (LV) anteroapical aneurysm. Myocardial infarction (MI) was induced by coil occlusion of the middle left anterior descending artery and diagonals. Two months after MI creation, TCVR was performed via a minimal thoracotomy in eight sheep. Under endoscopic and fluoroscopic guidance, trans-interventricular septal puncture was performed from the LV epicardial scar. A guidewire was externalised via a snare placed in the right ventricle from the external jugular vein. An internal anchor was inserted over the wire and positioned on the right ventricular septum and an external anchor was deployed on the LV anterior epicardium. Serial pairs of anchors were placed and plicated together to exclude the scar completely. Immediately after TCVR, echocardiography showed LV end-systolic volume decreased from pre-procedure 58.8±16.6 ml to 25.1±7.6 ml (p<0.01) and the ejection fraction increased from 32.0±7.3% to 52.0±7.5% (p<0.01). LV twist significantly improved (3.83±2.21 vs. pre-procedure -0.41±0.94, p=0.01) and the global peak-systolic longitudinal strain increased from -5.64% to -10.77% (p<0.05). TCVR using minimally invasive access techniques on the off-pump beating heart is feasible and resulted in significant improvement in LV performance.
- 21 January 2015
- Published by Springer Nature in Heart and Vessels
- Vol. 31 (4) , 519-527
Impact of intravascular ultrasound findings on long-term patency after self-expanding nitinol stent implantation in the iliac artery lesion
Although intravascular ultrasound (IVUS) predictors of stent patency for the coronary artery lesion have been established, little is known about IVUS predictors of stent patency for the aorto-iliac artery lesion. We analyzed 154 lesions of 122 patients who underwent stent implantation for iliac artery lesions. Quantitative and qualitative IVUS analyses were performed for pre- and post-procedural IVUS imaging in all lesions. Target lesion revascularization (TLR) was defined as clinically driven revascularization with >50 % angiographic stenosis of the target lesion. The mean follow-up period was 39 ± 16 months. TLRs were performed in 13 lesions (8.4 %). Post-procedural minimum stent area (MSA) was significantly smaller in the TLR group compared to the no-TLR group (16.0 ± 5.8 vs. 25.6 ± 8.5 mm(2), p < 0.001). Stent edge dissection was frequently observed in the TLR group compared to the no-TLR group (53.8 vs. 24.1 %, p = 0.04). Multivariate analysis revealed that post-procedural MSA (OR = 0.76, p < 0.01) and stent edge dissection (OR = 10.4, p < 0.01) were independent IVUS predictors of TLR. Receiver-operating characteristic analysis identified post-procedural MSA <17.8 mm(2) as the optimal cut-point for the prediction of TLR (AUC = 0.846). Post-procedural MSA and stent edge dissection could predict long-term stent patency in the iliac artery lesion. Our results propose that adequate stent enlargement without edge dissection might be important to reduce TLR in the iliac artery lesion.
- 21 January 2015
- Published by Springer Nature in Heart and Vessels
- Vol. 31 (4) , 519-527
Impact of intravascular ultrasound findings on long-term patency after self-expanding nitinol stent implantation in the iliac artery lesion
Although intravascular ultrasound (IVUS) predictors of stent patency for the coronary artery lesion have been established, little is known about IVUS predictors of stent patency for the aorto-iliac artery lesion. We analyzed 154 lesions of 122 patients who underwent stent implantation for iliac artery lesions. Quantitative and qualitative IVUS analyses were performed for pre- and post-procedural IVUS imaging in all lesions. Target lesion revascularization (TLR) was defined as clinically driven revascularization with >50 % angiographic stenosis of the target lesion. The mean follow-up period was 39 ± 16 months. TLRs were performed in 13 lesions (8.4 %). Post-procedural minimum stent area (MSA) was significantly smaller in the TLR group compared to the no-TLR group (16.0 ± 5.8 vs. 25.6 ± 8.5 mm(2), p < 0.001). Stent edge dissection was frequently observed in the TLR group compared to the no-TLR group (53.8 vs. 24.1 %, p = 0.04). Multivariate analysis revealed that post-procedural MSA (OR = 0.76, p < 0.01) and stent edge dissection (OR = 10.4, p < 0.01) were independent IVUS predictors of TLR. Receiver-operating characteristic analysis identified post-procedural MSA <17.8 mm(2) as the optimal cut-point for the prediction of TLR (AUC = 0.846). Post-procedural MSA and stent edge dissection could predict long-term stent patency in the iliac artery lesion. Our results propose that adequate stent enlargement without edge dissection might be important to reduce TLR in the iliac artery lesion.
- 30 August 2011
- Published by SAE International in SAE International Journal of Fuels and Lubricants
- Vol. 05 (1) , 146-153
Study of the Impact of High Biodiesel Blends on Engine Oil Performance
In Biodiesel Fuel Research Working Group(WG) of Japan Auto-Oil Program(JATOP), some impacts of high biodiesel blends have been investigated from the viewpoints of fuel properties, stability, emissions, exhaust aftertreatment systems, cold driveability, mixing in engine oils, durability/reliability and so on. This report is designed to determine how high biodiesel blends affect oil quality through testing on 2005 regulations engines with DPFs. When blends of 10-20% rapeseed methyl ester (RME) with diesel fuel are employed with 10W-30 engine oil, the oil change interval is reduced to about a half due to a drop in oil pressure. The oil pressure drop occurs because of the reduced kinematic viscosity of engine oil, which resulting from dilution of poorly evaporated RME with engine oil and its accumulation, however, leading to increased wear of piston top rings and cylinder liners. When a blend of 10% hydrogenated biodiesel (HBD) with diesel fuel is employed with 10W-30 engine oil, the pressure drop is smaller than that of 10-20% RME blends, because HBD has less heavy fraction compared to RME, and thus, even when diluting with engine oil, HBD can evaporate and is not apt to accumulate. Another study has been conducted to determine how 10% RME blends affect oil quality. 15W-40 engine oil is employed due to high initial oil pressure to avoid oil changes during the test period, resulting from dilution of RME with engine oil and its accumulation. The oil changes are avoided as planned; however, engine oil shows indications of degradation, such as increased total acid number and lead elution from the bearing material and components.
- 30 August 2011
- Published by SAE International in SAE International Journal of Fuels and Lubricants
- Vol. 05 (1) , 146-153
Study of the Impact of High Biodiesel Blends on Engine Oil Performance
In Biodiesel Fuel Research Working Group(WG) of Japan Auto-Oil Program(JATOP), some impacts of high biodiesel blends have been investigated from the viewpoints of fuel properties, stability, emissions, exhaust aftertreatment systems, cold driveability, mixing in engine oils, durability/reliability and so on. This report is designed to determine how high biodiesel blends affect oil quality through testing on 2005 regulations engines with DPFs. When blends of 10-20% rapeseed methyl ester (RME) with diesel fuel are employed with 10W-30 engine oil, the oil change interval is reduced to about a half due to a drop in oil pressure. The oil pressure drop occurs because of the reduced kinematic viscosity of engine oil, which resulting from dilution of poorly evaporated RME with engine oil and its accumulation, however, leading to increased wear of piston top rings and cylinder liners. When a blend of 10% hydrogenated biodiesel (HBD) with diesel fuel is employed with 10W-30 engine oil, the pressure drop is smaller than that of 10-20% RME blends, because HBD has less heavy fraction compared to RME, and thus, even when diluting with engine oil, HBD can evaporate and is not apt to accumulate. Another study has been conducted to determine how 10% RME blends affect oil quality. 15W-40 engine oil is employed due to high initial oil pressure to avoid oil changes during the test period, resulting from dilution of RME with engine oil and its accumulation. The oil changes are avoided as planned; however, engine oil shows indications of degradation, such as increased total acid number and lead elution from the bearing material and components.