Minghui Tang
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Minghui Tang has a total of 30 co-authors. Here are the top co-authors by number of shared publications:
- Guanghui Wang
College of Engineering and Applied Sciences, Nanjing University, Nanjing, China
3 shared publications - Ho-Pui Ho
Department of Biomedical Engineering, the Chinese University of Hong Kong, Shatin, Hong Kong SAR, 999077, China
2 shared publications Siu-Kai Kong
School of Life Sciences, The Chinese University of Hong Kong, Shatin, China
2 shared publicationsXuping Zhang
College of Engineering and Applied Sciences, Nanjing University, China
2 shared publications- Anqi Yang1 shared publication
Changbin Zhang
Nanjing University of Chinese Medicine, Nanjing, P.R. China
1 shared publication
Latest Publications
- Open Access
- 25 March 2022
- Published by Wiley in Advanced Science
- Vol. 9 (9)
Fish Capsules: A System for High‐Throughput Screening of Combinatorial Drugs (Adv. Sci. 9/2022)
High‐Throughput Screening of Combinatorial Drugs
- 25 March 2022
- Published by Wiley in Advanced Science
- Vol. 9 (9)
Open AccessFish Capsules: A System for High‐Throughput Screening of Combinatorial Drugs (Adv. Sci. 9/2022)
High‐Throughput Screening of Combinatorial Drugs
- 22 March 2018
- Published by Royal Society of Chemistry (RSC) in Lab on a Chip
- Vol. 18 (10) , 1452-1460
A linear concentration gradient generator based on multi-layered centrifugal microfluidics and its application in antimicrobial susceptibility testing
In almost any branch of chemistry or life sciences, it is often necessary to study the interaction between different components in a system by varying their respective concentrations in a systematic manner. Currently, many procedures for generating a series of samples of different solute concentration levels are still done manually by dilution. To address this issue, we present herein a highly automated linear concentration gradient generator based on centrifugal microfluidics. The operation of this device is based on the use of multi-layered microfluidics in which individual fluidic samples to be mixed together are stored and metered in their respective layers before finally being transferred to a mixing chamber. To demonstrate the operation of this scheme, we have used the device to conduct antimicrobial susceptibility testing (AST). Firstly, DI water, ampicillin solution and E. coli suspension were loaded into the chambers in different layers. As the device went through several rounds of spinning at different speeds, a series of metered dosages of ampicillin along a linear concentration gradient were introduced to the mixing chamber and mixed with E. coli automatically. By monitoring the spectral absorbance of the suspensions, we were able to establish the minimum inhibitory concentration (MIC) value of ampicillin against E. coli. The process took about 3 hours to complete, and the experimental results showed a strong correlation with those obtained with the standard CLSI broth dilution method. Clearly, the platform is useful for a wide range of applications such as drug discovery and personalised medicine, where concentration gradients are of concern.
- 22 March 2018
- Published by Royal Society of Chemistry (RSC) in Lab on a Chip
- Vol. 18 (10) , 1452-1460
A linear concentration gradient generator based on multi-layered centrifugal microfluidics and its application in antimicrobial susceptibility testing
In almost any branch of chemistry or life sciences, it is often necessary to study the interaction between different components in a system by varying their respective concentrations in a systematic manner. Currently, many procedures for generating a series of samples of different solute concentration levels are still done manually by dilution. To address this issue, we present herein a highly automated linear concentration gradient generator based on centrifugal microfluidics. The operation of this device is based on the use of multi-layered microfluidics in which individual fluidic samples to be mixed together are stored and metered in their respective layers before finally being transferred to a mixing chamber. To demonstrate the operation of this scheme, we have used the device to conduct antimicrobial susceptibility testing (AST). Firstly, DI water, ampicillin solution and E. coli suspension were loaded into the chambers in different layers. As the device went through several rounds of spinning at different speeds, a series of metered dosages of ampicillin along a linear concentration gradient were introduced to the mixing chamber and mixed with E. coli automatically. By monitoring the spectral absorbance of the suspensions, we were able to establish the minimum inhibitory concentration (MIC) value of ampicillin against E. coli. The process took about 3 hours to complete, and the experimental results showed a strong correlation with those obtained with the standard CLSI broth dilution method. Clearly, the platform is useful for a wide range of applications such as drug discovery and personalised medicine, where concentration gradients are of concern.
- 8 March 2018
- Published by Royal Society of Chemistry (RSC) in Lab on a Chip
- Vol. 18 (8) , 1197-1206
Binary centrifugal microfluidics enabling novel, digital addressable functions for valving and routing
Centrifugal microfluidics or lab-on-a-disc (LOAD) is a promising branch of lab-on-a-chip or microfluidics. Besides effective fluid transportation and inherently available density-based sample separation in centrifugal microfluidics, uniform actuation of flow on the disc makes the platform compact and scalable. However, the natural radially outward centrifugal force in a LOAD system limits its capacity to perform complex fluid manipulation steps. In order to increase the fluid manipulation freedom and integration capacity of the LOAD system, we propose a binary centrifugal microfluidics platform. With the help of Euler force, our platform allows free switching of both left and right states based on a rather simple mechanical structure. The periodical switching of state would provide a “clock” signal for a sequence of droplet binary logic operations. With the binary state platform and the “clock” signal, we can accurately handle the droplet separately in each time step with a maximum main frequency of about 10 S s−1 (switching per second). Apart from droplet manipulations such as droplet generation and metering, we also demonstrate a series of droplet logic operations, such as binary valving, droplet routing and digital addressable droplet storage. Furthermore, complex bioassays such as the Bradford assay and DNA purification assay are demonstrated on a binary platform, which is totally impossible for a traditional LOAD system. Our binary platform largely improves the capability for logic operation on the LOAD platform, and it is a simple and promising approach for microfluidic lab-on-a-disc large-scale integration.
- 8 March 2018
- Published by Royal Society of Chemistry (RSC) in Lab on a Chip
- Vol. 18 (8) , 1197-1206
Binary centrifugal microfluidics enabling novel, digital addressable functions for valving and routing
Centrifugal microfluidics or lab-on-a-disc (LOAD) is a promising branch of lab-on-a-chip or microfluidics. Besides effective fluid transportation and inherently available density-based sample separation in centrifugal microfluidics, uniform actuation of flow on the disc makes the platform compact and scalable. However, the natural radially outward centrifugal force in a LOAD system limits its capacity to perform complex fluid manipulation steps. In order to increase the fluid manipulation freedom and integration capacity of the LOAD system, we propose a binary centrifugal microfluidics platform. With the help of Euler force, our platform allows free switching of both left and right states based on a rather simple mechanical structure. The periodical switching of state would provide a “clock” signal for a sequence of droplet binary logic operations. With the binary state platform and the “clock” signal, we can accurately handle the droplet separately in each time step with a maximum main frequency of about 10 S s−1 (switching per second). Apart from droplet manipulations such as droplet generation and metering, we also demonstrate a series of droplet logic operations, such as binary valving, droplet routing and digital addressable droplet storage. Furthermore, complex bioassays such as the Bradford assay and DNA purification assay are demonstrated on a binary platform, which is totally impossible for a traditional LOAD system. Our binary platform largely improves the capability for logic operation on the LOAD platform, and it is a simple and promising approach for microfluidic lab-on-a-disc large-scale integration.
- 9 December 2016
- Published by Royal Society of Chemistry (RSC) in Lab on a Chip
- Vol. 17 (3) , 474-483
Motor-assisted chip-in-a-tube (MACT): a new 2- and 3-dimensional centrifugal microfluidic platform for biomedical applications
Currently, centrifuge apparatus is primarily an end-point sample processing piece of equipment. The lack of real-time active control has imposed an inherent limitation such that many delicate sample processing steps requiring immediate and accurate intervention have never been possible. We report herein a motor-assisted chip-in-a-tube (MACT) platform in which a microfluidic chip placed inside a common centrifuge canister can be rotated through wireless control in order to manipulate the centrifugal force vector in a 3-dimensional (3D) manner. As a demonstration experiment, we have used our MACT prototype to perform the operation for two common biomedical procedures, namely human blood plasma separation and E. coli plasmid DNA extraction. This simple, yet highly effective and versatile approach may serve as a generic one-for-all platform for a wide range of common laboratory experiments and bioassay applications.
- 9 December 2016
- Published by Royal Society of Chemistry (RSC) in Lab on a Chip
- Vol. 17 (3) , 474-483
Motor-assisted chip-in-a-tube (MACT): a new 2- and 3-dimensional centrifugal microfluidic platform for biomedical applications
Currently, centrifuge apparatus is primarily an end-point sample processing piece of equipment. The lack of real-time active control has imposed an inherent limitation such that many delicate sample processing steps requiring immediate and accurate intervention have never been possible. We report herein a motor-assisted chip-in-a-tube (MACT) platform in which a microfluidic chip placed inside a common centrifuge canister can be rotated through wireless control in order to manipulate the centrifugal force vector in a 3-dimensional (3D) manner. As a demonstration experiment, we have used our MACT prototype to perform the operation for two common biomedical procedures, namely human blood plasma separation and E. coli plasmid DNA extraction. This simple, yet highly effective and versatile approach may serve as a generic one-for-all platform for a wide range of common laboratory experiments and bioassay applications.