Paul Hansen
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Paul Hansen has a total of 13 co-authors. Here are the top co-authors by number of shared publications:
- Tim Foster
Institute for Sustainable Futures, University of Technology Sydney, Sydney, Australia
3 shared publications - Barbara Evans
University of Leeds
2 shared publications - Cindy Rianti Priadi
Environmental Engineering Study Program, Department of Civil and Environmental Engineering, Universitas Indonesia, Depok, Indonesia
2 shared publications - Freya Mills
University of Technology Sydney
2 shared publications Juliet Willetts
Institute for Sustainable Futures, University of Technology Sydney, Sydney, Australia
2 shared publications- Juliet Willetts
Institute for Sustainable Futures, University of Technology Sydney, P.O. Box 123, Broadway, NSW 2007, Australia
2 shared publications
Latest Publications
- Open Access
- 23 September 2026
- Published by Springer Nature in Environmental Monitoring and Assessment
- Vol. 198 (10) , 1098
Ranking microbial risk of self-supplied groundwater in urban Indonesia
In Indonesia, 61% of urban households use self-supplied groundwater, with 24% relying on it as a primary drinking water source. Many self-supplied sources contain faecal contamination, posing health risks. Identifying locations with elevated contamination risk can help target piped-water investments and interim safety measures, but collecting sufficient water quality data is costly. This study develops and validates a method to rank contamination risk across Indonesian cities using secondary data alone. Contamination probability was modelled using logistic regression applied to water quality data from 619 households in Indonesia’s 2020 national water quality survey. A composite city-level risk score was constructed by combining predicted contamination probability with the proportion of households relying on self-supplied groundwater, derived from Indonesia’s 2022 national socioeconomic survey, enabling risk ranking across all 99 cities. Dug-wells had 2.9 times greater odds of Escherichia coli >100 CFU/100 mL than boreholes ( p < 0.001), and contamination risk increased significantly with population density ( p = 0.006). Aquifer lithology and rainfall were additional predictors ( p < 0.1). Model discrimination was acceptable (AUC 0.715, 95% CI 0.667–0.764). Independent validation against four datasets (14 locations) revealed acceptable agreement but systematic underprediction of E. coli exceedance probability at four locations (root mean square error of 0.116 and mean bias of −0.067), indicating the model is more reliable for identifying lower-risk than higher-risk cities. Including groundwater depth and sanitary condition data could increase model reliability. This approach provides a cost-effective screening tool for prioritising water-safety interventions where urban self-supply is widespread and data is limited.
- 23 September 2026
- Published by Springer Nature in Environmental Monitoring and Assessment
- Vol. 198 (10) , 1098
Open AccessRanking microbial risk of self-supplied groundwater in urban Indonesia
In Indonesia, 61% of urban households use self-supplied groundwater, with 24% relying on it as a primary drinking water source. Many self-supplied sources contain faecal contamination, posing health risks. Identifying locations with elevated contamination risk can help target piped-water investments and interim safety measures, but collecting sufficient water quality data is costly. This study develops and validates a method to rank contamination risk across Indonesian cities using secondary data alone. Contamination probability was modelled using logistic regression applied to water quality data from 619 households in Indonesia’s 2020 national water quality survey. A composite city-level risk score was constructed by combining predicted contamination probability with the proportion of households relying on self-supplied groundwater, derived from Indonesia’s 2022 national socioeconomic survey, enabling risk ranking across all 99 cities. Dug-wells had 2.9 times greater odds of Escherichia coli >100 CFU/100 mL than boreholes ( p < 0.001), and contamination risk increased significantly with population density ( p = 0.006). Aquifer lithology and rainfall were additional predictors ( p < 0.1). Model discrimination was acceptable (AUC 0.715, 95% CI 0.667–0.764). Independent validation against four datasets (14 locations) revealed acceptable agreement but systematic underprediction of E. coli exceedance probability at four locations (root mean square error of 0.116 and mean bias of −0.067), indicating the model is more reliable for identifying lower-risk than higher-risk cities. Including groundwater depth and sanitary condition data could increase model reliability. This approach provides a cost-effective screening tool for prioritising water-safety interventions where urban self-supply is widespread and data is limited.
- Open Access
- 30 December 2025
- Published by IWA Publishing in Journal of Water, Sanitation and Hygiene for Development
- Vol. 16 (1) , 36-44
Associations between sanitary inspection risk factors and E. coli contamination in household groundwater sources
Over 760 million people across South Asia, Southeast Asia, and the Pacific rely on self-supplied drinking water, which is frequently contaminated with faecal indicator bacteria such as Escherichia coli. Sanitary inspections (SIs) are widely used to identify contamination risks. The relationship between SI and water quality is complex, with mixed findings from previous work. This study seeks to build on the evidence by examining associations between sanitary risk factors and the presence of E. coli in household groundwater sources in Indonesia, using data from a nationally representative drinking water quality survey that sampled 6,549 households (4,104 dug wells, 2,445 boreholes). Multiple logistic regression was used to assess associations between individual SI risk factors, overall sanitary scores, and E. coli detection in boreholes and dug wells across urban and rural settings. Significant associations (p < 0.05) were found between E. coli and sanitary scores and risk factors, including poor plastering of rims in urban dug wells, and other sources of pollution within 10 m for rural boreholes. No significant associations were observed for urban boreholes. These findings suggest that SI tools may require adaptation for urban groundwater contexts and that hydrogeological data should be used to determine context-specific separation distances.
- 30 December 2025
- Published by IWA Publishing in Journal of Water, Sanitation and Hygiene for Development
- Vol. 16 (1) , 36-44
Open AccessAssociations between sanitary inspection risk factors and E. coli contamination in household groundwater sources
Over 760 million people across South Asia, Southeast Asia, and the Pacific rely on self-supplied drinking water, which is frequently contaminated with faecal indicator bacteria such as Escherichia coli. Sanitary inspections (SIs) are widely used to identify contamination risks. The relationship between SI and water quality is complex, with mixed findings from previous work. This study seeks to build on the evidence by examining associations between sanitary risk factors and the presence of E. coli in household groundwater sources in Indonesia, using data from a nationally representative drinking water quality survey that sampled 6,549 households (4,104 dug wells, 2,445 boreholes). Multiple logistic regression was used to assess associations between individual SI risk factors, overall sanitary scores, and E. coli detection in boreholes and dug wells across urban and rural settings. Significant associations (p < 0.05) were found between E. coli and sanitary scores and risk factors, including poor plastering of rims in urban dug wells, and other sources of pollution within 10 m for rural boreholes. No significant associations were observed for urban boreholes. These findings suggest that SI tools may require adaptation for urban groundwater contexts and that hydrogeological data should be used to determine context-specific separation distances.
- Open Access
- 29 July 2024
- Published by Public Library of Science (PLoS) in PLOS Water
- Vol. 3 (7) , e0000167
Onsite sanitation systems and contamination of groundwater: A systematic review of the evidence for risk using the source-pathway-receptor model
The level of risk that onsite sanitation systems (OSS) pose to groundwater quality remains uncertain. The link between contamination and OSS can only be proved if the source, pathway, and receptor are investigated and confirmed when assessing contamination. The literature on the connection between OSS and groundwater contamination has been reviewed several times but with limited assessments of the extent to which the literature confirms that the source of contamination is an OSS, that a pathway has been identified, and that the receptor is groundwater. A systematic review was conducted on published studies and supports previous work that concluded that the removal and transport of contaminants from OSS to groundwater is complex and varies significantly according to local conditions. This variability means simple siting guidelines based on horizontal separation are not reliable. Though not always recognised in the literature, formation of a biological layer is important for removal of microbial pathogens. This layer takes months to form which impacts the performance of OSS that are new or subject to highly variable loading. Under ideal conditions of an unsaturated zone comprising fine material, faecal indicator bacteria can be reduced to detection limits within 10 metres distance. However, ideal conditions are very often not present. Multiple studies showed the presence of viruses in the absence of faecal indicator bacteria. Ingress of contaminated surface water into faulty boreholes/wells and contamination of wells from users are both often significant yet not adequately covered in the included literature. The review established that it is extremely difficult to eliminate the risk of groundwater contamination when OSS effluent is discharged into the subsurface. It is unsafe to assume that contamination can be prevented in areas with high OSS density, and further research is needed to determine the critical density threshold for different ground conditions.
- 29 July 2024
- Published by Public Library of Science (PLoS) in PLOS Water
- Vol. 3 (7) , e0000167
Open AccessOnsite sanitation systems and contamination of groundwater: A systematic review of the evidence for risk using the source-pathway-receptor model
The level of risk that onsite sanitation systems (OSS) pose to groundwater quality remains uncertain. The link between contamination and OSS can only be proved if the source, pathway, and receptor are investigated and confirmed when assessing contamination. The literature on the connection between OSS and groundwater contamination has been reviewed several times but with limited assessments of the extent to which the literature confirms that the source of contamination is an OSS, that a pathway has been identified, and that the receptor is groundwater. A systematic review was conducted on published studies and supports previous work that concluded that the removal and transport of contaminants from OSS to groundwater is complex and varies significantly according to local conditions. This variability means simple siting guidelines based on horizontal separation are not reliable. Though not always recognised in the literature, formation of a biological layer is important for removal of microbial pathogens. This layer takes months to form which impacts the performance of OSS that are new or subject to highly variable loading. Under ideal conditions of an unsaturated zone comprising fine material, faecal indicator bacteria can be reduced to detection limits within 10 metres distance. However, ideal conditions are very often not present. Multiple studies showed the presence of viruses in the absence of faecal indicator bacteria. Ingress of contaminated surface water into faulty boreholes/wells and contamination of wells from users are both often significant yet not adequately covered in the included literature. The review established that it is extremely difficult to eliminate the risk of groundwater contamination when OSS effluent is discharged into the subsurface. It is unsafe to assume that contamination can be prevented in areas with high OSS density, and further research is needed to determine the critical density threshold for different ground conditions.
- Open Access
- 30 July 2023
- Published by California Digital Library (CDL) in EarthArXiv
Onsite sanitation systems and contamination of groundwater: A systematic review of the evidence for risk using the source-pathway-receptor model.
The level of risk that onsite sanitation systems (OSS) pose to groundwater quality remains uncertain. The link between contamination and OSS can only be proved if the source, pathway, and receptor (SPR) are investigated and confirmed when assessing contamination. The literature on the connection between OSS and groundwater contamination has been reviewed several times. However, previous reviews have made limited assessments of the extent to which the literature confirms that the source of contamination is an OSS, that a pathway has been identified, and that the receptor is groundwater, mainly due to uncertainties or insufficiencies in reported methodologies.A systematic review was conducted on published studies with the aim of establishing the state of knowledge of groundwater contamination from onsite sanitation systems that infiltrate wastewater into ground, such as pit latrines and septic tank systems. The quality of the methods used to establish the source, pathway and receptor was assessed. The review focussed on three main contaminants: bacteria, viruses and nitrates.Scopus, PubMed, and Web of Science databases were searched, screening criterion developed and applied, and 60 eligible papers were identified. 35 of these were rated as having a “strong methodology”. The selected studies were assessed to identify areas of knowledge regarding the interaction of OSS with groundwater where there is strong supportive evidence and where there are knowledge gaps.The review supports previous work that has concluded that the removal and transport of contaminants from OSS to groundwater is complex and varies significantly according to local conditions, including the nature of the ground materials, groundwater levels, ground moisture and other factors. This variability means simple siting guidelines based on horizontal separation are not reliable.Though not always recognised in the literature, formation of a biological layer is important for removal of microbial pathogens. This layer takes months to form which impacts the performance of OSS that are new or subject to highly variable loading or sudden increases in hydraulic load.Under ideal conditions of an unsaturated zone comprising fine material (sands, silts, loams with some clay content, Faecal indicator bacteria can be reduced to detection limits within 10 metres distance. However, ideal conditions are very often not present. Multiple studies showed the presence of viruses in the absence of faecal indicator bacteria. Contamination can also occur via localised pathways, but these have not been thoroughly investigated. Contribution of the ingress of contaminated surface water into faulty boreholes/wells and contamination of wells through the spigot or spout from users are both often significant yet not adequately covered in the included literature.The review established that it is extremely difficult to eliminate the risk of groundwater contamination when OSS effluent is discharged into the subsurface. Generally, it seems unsafe to assume that contamination can be prevented in areas where OSS occur with any frequency.
- 30 July 2023
- Published by California Digital Library (CDL) in EarthArXiv
Open AccessOnsite sanitation systems and contamination of groundwater: A systematic review of the evidence for risk using the source-pathway-receptor model.
The level of risk that onsite sanitation systems (OSS) pose to groundwater quality remains uncertain. The link between contamination and OSS can only be proved if the source, pathway, and receptor (SPR) are investigated and confirmed when assessing contamination. The literature on the connection between OSS and groundwater contamination has been reviewed several times. However, previous reviews have made limited assessments of the extent to which the literature confirms that the source of contamination is an OSS, that a pathway has been identified, and that the receptor is groundwater, mainly due to uncertainties or insufficiencies in reported methodologies.A systematic review was conducted on published studies with the aim of establishing the state of knowledge of groundwater contamination from onsite sanitation systems that infiltrate wastewater into ground, such as pit latrines and septic tank systems. The quality of the methods used to establish the source, pathway and receptor was assessed. The review focussed on three main contaminants: bacteria, viruses and nitrates.Scopus, PubMed, and Web of Science databases were searched, screening criterion developed and applied, and 60 eligible papers were identified. 35 of these were rated as having a “strong methodology”. The selected studies were assessed to identify areas of knowledge regarding the interaction of OSS with groundwater where there is strong supportive evidence and where there are knowledge gaps.The review supports previous work that has concluded that the removal and transport of contaminants from OSS to groundwater is complex and varies significantly according to local conditions, including the nature of the ground materials, groundwater levels, ground moisture and other factors. This variability means simple siting guidelines based on horizontal separation are not reliable.Though not always recognised in the literature, formation of a biological layer is important for removal of microbial pathogens. This layer takes months to form which impacts the performance of OSS that are new or subject to highly variable loading or sudden increases in hydraulic load.Under ideal conditions of an unsaturated zone comprising fine material (sands, silts, loams with some clay content, Faecal indicator bacteria can be reduced to detection limits within 10 metres distance. However, ideal conditions are very often not present. Multiple studies showed the presence of viruses in the absence of faecal indicator bacteria. Contamination can also occur via localised pathways, but these have not been thoroughly investigated. Contribution of the ingress of contaminated surface water into faulty boreholes/wells and contamination of wells through the spigot or spout from users are both often significant yet not adequately covered in the included literature.The review established that it is extremely difficult to eliminate the risk of groundwater contamination when OSS effluent is discharged into the subsurface. Generally, it seems unsafe to assume that contamination can be prevented in areas where OSS occur with any frequency.