C. Kalaivanan
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
C. Kalaivanan has a total of 11 co-authors. Here are the top co-authors by number of shared publications:
S. Chandrasekar
Sona College of Technology
3 shared publicationsAndrea Cavallini
LIMAT, University of Bologna, Bologna, Italy
2 shared publicationsGian Carlo Montanari
LIMAT, University of Bologna, Bologna, Italy
2 shared publicationsBhuvaneshwarri
Department of Information Technology, Government College of Engineering, Erode - 638316, Tamil Nadu, India
1 shared publicationDijin Divakaran
SonaPERT, Department of EEE, Sona College of Technology, Salem 636005, USA
1 shared publication- M. Maheswari
Associate Professor, Department of Computational Intelligence, SRM Institute of Science and Technology, Kattankulathur, Tamilnadu, India.603203
1 shared publication
Latest Publications
- Open Access
- 30 December 2024
- Published by Iskender AKKURT in International Journal of Computational and Experimental Science and Engineering
- Vol. 11 (1)
Hybrid Swarm Intelligence-Based Neural Framework for Optimizing Real-Time Computational Models in Engineering Systems
In modern engineering systems, real-time computational models are essential for optimizing performance, enhancing decision-making, and reducing latency in complex environments. This research presents a Hybrid Swarm Intelligence-Based Neural Framework (HSIN-F) to improve the efficiency, accuracy, and adaptability of real-time engineering computations. The proposed framework integrates Particle Swarm Optimization (PSO), Grey Wolf Optimizer (GWO), and Ant Colony Optimization (ACO) with a Deep Neural Network (DNN) to achieve a balance between exploration and exploitation, enabling optimal model parameter selection and reducing computational overhead. To validate the efficiency of HSIN-F, experiments were conducted across various real-time engineering applications, including industrial automation, smart grids, and IoT-based systems. The proposed model outperformed conventional optimization techniques in terms of processing speed, predictive accuracy, and system adaptability. Key performance metrics include: Prediction Accuracy: 98.2% (compared to 93.5% in traditional models), Computational Latency Reduction: 34.7%, Energy Efficiency Improvement: 27.5%, Error Rate Reduction: 32.1%. The hybrid swarm-based approach effectively adapts to dynamic changes in real-time scenarios, making it highly suitable for engineering applications requiring continuous optimization. Future research will explore hybrid metaheuristic strategies and federated learning-based decentralization to further enhance system performance and robustness.
- 30 December 2024
- Published by Iskender AKKURT in International Journal of Computational and Experimental Science and Engineering
- Vol. 11 (1)
Open AccessHybrid Swarm Intelligence-Based Neural Framework for Optimizing Real-Time Computational Models in Engineering Systems
In modern engineering systems, real-time computational models are essential for optimizing performance, enhancing decision-making, and reducing latency in complex environments. This research presents a Hybrid Swarm Intelligence-Based Neural Framework (HSIN-F) to improve the efficiency, accuracy, and adaptability of real-time engineering computations. The proposed framework integrates Particle Swarm Optimization (PSO), Grey Wolf Optimizer (GWO), and Ant Colony Optimization (ACO) with a Deep Neural Network (DNN) to achieve a balance between exploration and exploitation, enabling optimal model parameter selection and reducing computational overhead. To validate the efficiency of HSIN-F, experiments were conducted across various real-time engineering applications, including industrial automation, smart grids, and IoT-based systems. The proposed model outperformed conventional optimization techniques in terms of processing speed, predictive accuracy, and system adaptability. Key performance metrics include: Prediction Accuracy: 98.2% (compared to 93.5% in traditional models), Computational Latency Reduction: 34.7%, Energy Efficiency Improvement: 27.5%, Error Rate Reduction: 32.1%. The hybrid swarm-based approach effectively adapts to dynamic changes in real-time scenarios, making it highly suitable for engineering applications requiring continuous optimization. Future research will explore hybrid metaheuristic strategies and federated learning-based decentralization to further enhance system performance and robustness.
- 30 September 2019
- Published by Springer Nature in Journal of Electrical Engineering & Technology
- Vol. 14 (6) , 2447-2454
A Study on the Influence of SiO2 Nano Particles on the Failure of XLPE Underground Cables due to Electrical Treeing
- 30 September 2019
- Published by Springer Nature in Journal of Electrical Engineering & Technology
- Vol. 14 (6) , 2447-2454
A Study on the Influence of SiO2 Nano Particles on the Failure of XLPE Underground Cables due to Electrical Treeing
- 1 July 2012
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- No. 21609225,p. 1-4
Investigation of lightning impulse voltage characteristics and other thermo-physical characteristics of vegetable oils for power apparatus applications
Interests on vegetable oils as replacement of mineral oil in power apparatus are growing in recent years due to their better environmental performance and higher fire safety guarantee. The major aim of this research work is to identify a suitable high performance, eco-friendly, biodegradable vegetable oil as a dielectric fluid for transformer and other power apparatus applications. Having this in view, the key objective is to perform the laboratory experiments as per International Electro technical Commission test procedures to understand the Lightning Impulse Voltage Characteristics and other thermo-physical characteristics of various vegetable oils such as palm oil and coconut oil under both virgin and aged conditions. Vegetable oils are at least 97% biodegradable and its spillage causes no harm to the environment. Also the oils are easily available. In order to identify a suitable vegetable oil as an alternate for conventional mineral oil, experimental results are compared with the mineral oil and reported in this paper.
- 1 July 2012
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- No. 21609225,p. 1-4
Investigation of lightning impulse voltage characteristics and other thermo-physical characteristics of vegetable oils for power apparatus applications
Interests on vegetable oils as replacement of mineral oil in power apparatus are growing in recent years due to their better environmental performance and higher fire safety guarantee. The major aim of this research work is to identify a suitable high performance, eco-friendly, biodegradable vegetable oil as a dielectric fluid for transformer and other power apparatus applications. Having this in view, the key objective is to perform the laboratory experiments as per International Electro technical Commission test procedures to understand the Lightning Impulse Voltage Characteristics and other thermo-physical characteristics of various vegetable oils such as palm oil and coconut oil under both virgin and aged conditions. Vegetable oils are at least 97% biodegradable and its spillage causes no harm to the environment. Also the oils are easily available. In order to identify a suitable vegetable oil as an alternate for conventional mineral oil, experimental results are compared with the mineral oil and reported in this paper.
- 17 February 2010
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Dielectrics and Electrical Insulation
- Vol. 17 (1) , 181-188
Partial discharge detection as a tool to infer pollution severity of polymeric insulators
This paper deals with the analysis of partial discharge characteristics of silicone rubber insulators, with the aim to develop a better diagnostic tool to identify the pollution severity of outdoor insulators. In this work, laboratory-based pollution performance tests are carried out on silicone rubber insulators under ac voltage at different pollution levels and relative humidity conditions, using sodium chloride as a contaminant. Partial discharge (PD) is acquired through an innovative PD detection system which is able to collect PD waveforms beside PD patterns. Time domain and frequency domain characteristics of PD pulses at different surface pollution conditions are studied. Statistical parameters of PD patterns are also evaluated in order to achieve a quantitative assessment of pollution severity of polymeric insulators. The results on silicone rubber insulators show that the pollution severity of outdoor polymeric insulators could be identified from the partial discharge pattern analysis.
- 17 February 2010
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Dielectrics and Electrical Insulation
- Vol. 17 (1) , 181-188
Partial discharge detection as a tool to infer pollution severity of polymeric insulators
This paper deals with the analysis of partial discharge characteristics of silicone rubber insulators, with the aim to develop a better diagnostic tool to identify the pollution severity of outdoor insulators. In this work, laboratory-based pollution performance tests are carried out on silicone rubber insulators under ac voltage at different pollution levels and relative humidity conditions, using sodium chloride as a contaminant. Partial discharge (PD) is acquired through an innovative PD detection system which is able to collect PD waveforms beside PD patterns. Time domain and frequency domain characteristics of PD pulses at different surface pollution conditions are studied. Statistical parameters of PD patterns are also evaluated in order to achieve a quantitative assessment of pollution severity of polymeric insulators. The results on silicone rubber insulators show that the pollution severity of outdoor polymeric insulators could be identified from the partial discharge pattern analysis.
- 17 April 2009
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Dielectrics and Electrical Insulation
- Vol. 16 (2) , 574-583
Investigations on leakage current and phase angle characteristics of porcelain and polymeric insulator under contaminated conditions
This paper deals with the analysis of leakage current and phase angle characteristics of porcelain and silicone rubber insulator in order to develop a better diagnostic tool to identify the pollution severity of outdoor insulators. In this work, laboratory based pollution performance tests are carried out on porcelain and silicone rubber insulator under ac voltage at different pollution levels and relative humidity conditions with sodium chloride as a contaminant. Multi resolution signal decomposition (MRSD) using discrete wavelet transform (DWT) is employed to understand the time-frequency characteristics of the leakage current signal. Fast Fourier transform (FFT) spectral analysis is adopted to calculate the phase angle values of the applied voltage and leakage current signals. Reported results on porcelain and silicone rubber insulators show that the pollution severity of outdoor insulators could be identified from the DWT STD-MRA (standard deviation multi resolution analysis) distortion ratio pattern analysis of leakage current signals.
- 17 April 2009
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Dielectrics and Electrical Insulation
- Vol. 16 (2) , 574-583
Investigations on leakage current and phase angle characteristics of porcelain and polymeric insulator under contaminated conditions
This paper deals with the analysis of leakage current and phase angle characteristics of porcelain and silicone rubber insulator in order to develop a better diagnostic tool to identify the pollution severity of outdoor insulators. In this work, laboratory based pollution performance tests are carried out on porcelain and silicone rubber insulator under ac voltage at different pollution levels and relative humidity conditions with sodium chloride as a contaminant. Multi resolution signal decomposition (MRSD) using discrete wavelet transform (DWT) is employed to understand the time-frequency characteristics of the leakage current signal. Fast Fourier transform (FFT) spectral analysis is adopted to calculate the phase angle values of the applied voltage and leakage current signals. Reported results on porcelain and silicone rubber insulators show that the pollution severity of outdoor insulators could be identified from the DWT STD-MRA (standard deviation multi resolution analysis) distortion ratio pattern analysis of leakage current signals.
- 1 December 2008
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-5
Study on Pollution Severity of Porcelain Insulators Using LC and Phase Angle Measurement
This paper deals with the analysis of pollution severity of power transmission line porcelain insulators under wet conditions using leakage current (LC) and phase angle measurement. In this work, laboratory based experiments were carried out on single disc porcelain insulator under AC voltages at different pollution conditions with sodium chloride as a contaminant. Leakage current and voltage waveform during the experimental studies were measured. Phase angle relationship between the leakage current and voltage were calculated. Variation in leakage current and phase angle relationship at different pollution levels is used to identify the various stages involved in the failure due to flashover. The reported results of this preliminary study on single disc porcelain insulator enable more accurate diagnosis of flashover of insulator due to pollution.
- 1 December 2008
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-5
Study on Pollution Severity of Porcelain Insulators Using LC and Phase Angle Measurement
This paper deals with the analysis of pollution severity of power transmission line porcelain insulators under wet conditions using leakage current (LC) and phase angle measurement. In this work, laboratory based experiments were carried out on single disc porcelain insulator under AC voltages at different pollution conditions with sodium chloride as a contaminant. Leakage current and voltage waveform during the experimental studies were measured. Phase angle relationship between the leakage current and voltage were calculated. Variation in leakage current and phase angle relationship at different pollution levels is used to identify the various stages involved in the failure due to flashover. The reported results of this preliminary study on single disc porcelain insulator enable more accurate diagnosis of flashover of insulator due to pollution.