Bing Chen
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Bing Chen has a total of 8 co-authors. Here are the top co-authors by number of shared publications:
- Chun-Hao Zhong
Department of Mechanical and Automation Engineering, The Chinese University of Hong Kong, Hong Kong
1 shared publication - Hao Ma
The Chinese University of Hong Kong
1 shared publication - Kai-Ming Chan
The Chinese University of Hong Kong
1 shared publication - Lai-Yin Qin
The Chinese University of Hong Kong
1 shared publication - Ling Qin
Centre for Translational Medicine Research and Development, Shenzhen Institutes of Advanced Technology, Chinese Academy of Sciences, Shenzhen, China
1 shared publication - Sheung-Wai Law
Department of Orthopaedics and Traumatology, the Chinese University of Hong Kong, Hong Kong, People’s Republic of China
1 shared publication
Latest Publications
- 27 November 2017
- Published by Cambridge University Press (CUP) in Robotica
- Vol. 36 (4) , 535-551
Sit-to-stand and stand-to-sit assistance for paraplegic patients with CUHK-EXO exoskeleton
SUMMARY: In this paper, we introduce a lower extremity exoskeleton CUHK-EXO that is developed to help paraplegic patients, who have lost the motor and sensory functions of their lower limbs to perform basic daily life motions. Since the sit-to-stand and stand-to-sit (STS) motion is the first step for paraplegic patients toward walking, analysis of the exoskeleton's applicability to the STS motion assistance is performed. First, the human-exoskeleton system (HES) is modeled as a five-link model during the STS motion, and the center of pressure (COP) on the ground and center of gravity of the whole system are calculated. Then, a description of the CUHK-EXO hardware design is presented, including the mechatronics design and actuator selection. The COP position is an important factor indicating system balance and wearer's comfort. Based on the COP position, a trajectory online modification algorithm (TOMA) is proposed for CUHK-EXO to counteract disturbances, stabilize system balance, and improve the wearer's comfort in the STS motion. The results of STS motion tests conducted with a paraplegic patient demonstrate that CUHK-EXO can provide a normal reference pattern and proper assistive torque to support the patient's STS motion. In addition, a pilot study is conducted with a healthy subject to verify the effectiveness of the proposed TOMA under external disturbances before future clinical trials. The testing results verify that CUHK-EXO can counteract disturbances, and help the wearer perform the STS motion safely and comfortably.
- 27 November 2017
- Published by Cambridge University Press (CUP) in Robotica
- Vol. 36 (4) , 535-551
Sit-to-stand and stand-to-sit assistance for paraplegic patients with CUHK-EXO exoskeleton
SUMMARY: In this paper, we introduce a lower extremity exoskeleton CUHK-EXO that is developed to help paraplegic patients, who have lost the motor and sensory functions of their lower limbs to perform basic daily life motions. Since the sit-to-stand and stand-to-sit (STS) motion is the first step for paraplegic patients toward walking, analysis of the exoskeleton's applicability to the STS motion assistance is performed. First, the human-exoskeleton system (HES) is modeled as a five-link model during the STS motion, and the center of pressure (COP) on the ground and center of gravity of the whole system are calculated. Then, a description of the CUHK-EXO hardware design is presented, including the mechatronics design and actuator selection. The COP position is an important factor indicating system balance and wearer's comfort. Based on the COP position, a trajectory online modification algorithm (TOMA) is proposed for CUHK-EXO to counteract disturbances, stabilize system balance, and improve the wearer's comfort in the STS motion. The results of STS motion tests conducted with a paraplegic patient demonstrate that CUHK-EXO can provide a normal reference pattern and proper assistive torque to support the patient's STS motion. In addition, a pilot study is conducted with a healthy subject to verify the effectiveness of the proposed TOMA under external disturbances before future clinical trials. The testing results verify that CUHK-EXO can counteract disturbances, and help the wearer perform the STS motion safely and comfortably.