Huabin Wen
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Huabin Wen has a total of 5 co-authors. Here are the top co-authors by number of shared publications:
Mingzhi Zhang
School of Electrical Engineering Beijing Jiaotong University Haidian District Beijing 100044 People's Republic of China
2 shared publicationsYi Wang
School of Electrical Engineering Beijing Jiaotong University Haidian District Beijing 100044 People's Republic of China
2 shared publicationsPeng Li
School of Electronic and Information Engineering Beijing Jiaotong University Haidian District Beijing 100044 People's Republic of China
1 shared publication- Peng Li
School of Automation and Intelligence, Beijing Jiaotong University, Beijing 100044, China
1 shared publication Shuti Wang
School of Electronic and Information Engineering Beijing Jiaotong University Haidian District Beijing 100044 People's Republic of China
1 shared publication
Latest Publications
- Open Access
- 14 June 2019
- Published by Institution of Engineering and Technology (IET) in IET Generation, Transmission & Distribution
- Vol. 13 (13) , 2646-2651
Analysis and design of a pulse‐closing vacuum switch for catenary fault detection
This study presents a novel pulse‐closing vacuum switch (PCVS) that is used for catenary fault detection and location. First, as the application background of PCVS, the principle theory of the fault detection and locating system is briefly introduced. Then, the PCVS is analysed and designed based on the detailed analysis of its working process and principle. To validate the performance of the designed PCVS, the multi‐physical domain co‐simulation numerical model is implemented using the ANSYS Maxwell and ANSYS Simplorer. Finally, a PCVS prototype is developed with permanent magnet closing and repulsive force opening to verify the simulation results. The simulations and experiments both approve that the contact time between the moveable contact and static contact can be controlled to be <6 ms. This meets the pulse‐closing technology requirement for the fault detection and locating system.
- 14 June 2019
- Published by Institution of Engineering and Technology (IET) in IET Generation, Transmission & Distribution
- Vol. 13 (13) , 2646-2651
Open AccessAnalysis and design of a pulse‐closing vacuum switch for catenary fault detection
This study presents a novel pulse‐closing vacuum switch (PCVS) that is used for catenary fault detection and location. First, as the application background of PCVS, the principle theory of the fault detection and locating system is briefly introduced. Then, the PCVS is analysed and designed based on the detailed analysis of its working process and principle. To validate the performance of the designed PCVS, the multi‐physical domain co‐simulation numerical model is implemented using the ANSYS Maxwell and ANSYS Simplorer. Finally, a PCVS prototype is developed with permanent magnet closing and repulsive force opening to verify the simulation results. The simulations and experiments both approve that the contact time between the moveable contact and static contact can be controlled to be <6 ms. This meets the pulse‐closing technology requirement for the fault detection and locating system.
- Open Access
- 27 November 2017
- Published by Institution of Engineering and Technology (IET) in IET Electric Power Applications
- Vol. 12 (2) , 247-253
Comparative studies on two electromagnetic repulsion mechanisms for high‐speed vacuum switch
The electromagnetic repulsion mechanism (ERM) is highly consistent with the operation mechanisms of the high‐speed switch (HSS) owing to its simple structure and fast response capability. To investigate the performance difference between the coil–disk ERM and the coil–coil ERM, the authors adopt the finite element models for simulations with the aid of ANSYS Maxwell software. Then, an HSS prototype based on the mechanism of permanent magnet closing and repulsion force opening is developed to verify the numerical simulations. Simulations and experiments demonstrate that under the same excitation conditions, the coil–disk ERM has shorter inherent open time, while the coil–coil ERM has shorter full stroke time. Moreover, it is shown that the difference between the full stroke times of the two mechanisms gradually decreases with the increasing discharging energy.
- 27 November 2017
- Published by Institution of Engineering and Technology (IET) in IET Electric Power Applications
- Vol. 12 (2) , 247-253
Open AccessComparative studies on two electromagnetic repulsion mechanisms for high‐speed vacuum switch
The electromagnetic repulsion mechanism (ERM) is highly consistent with the operation mechanisms of the high‐speed switch (HSS) owing to its simple structure and fast response capability. To investigate the performance difference between the coil–disk ERM and the coil–coil ERM, the authors adopt the finite element models for simulations with the aid of ANSYS Maxwell software. Then, an HSS prototype based on the mechanism of permanent magnet closing and repulsion force opening is developed to verify the numerical simulations. Simulations and experiments demonstrate that under the same excitation conditions, the coil–disk ERM has shorter inherent open time, while the coil–coil ERM has shorter full stroke time. Moreover, it is shown that the difference between the full stroke times of the two mechanisms gradually decreases with the increasing discharging energy.