Andrew V. Grassetti
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Andrew V. Grassetti has a total of 6 co-authors. Here are the top co-authors by number of shared publications:
- Joseph H. Davis
Department of Biology, Massachusetts Institute of Technology
3 shared publications Davis Jh
2 shared publicationsKinman Lf
2 shared publications- Laurel F. Kinman
Department of Biology, Massachusetts Institute of Technology, Cambridge, MA
2 shared publications - Maria V. Carreira
Department of Biology, Massachusetts Institute of Technology, Cambridge, MA
1 shared publication - Mira B. May
Department of Biology, Massachusetts Institute of Technology, Cambridge, USA
1 shared publication
Latest Publications
- Open Access
Heterogeneous reconstruction algorithms for cryoEM achieve limited particle classification accuracy on real benchmark datasets
The emergence of single-particle cryoEM as a powerful method for structure determination has in large part been fueled by its ability to resolve both single static structures and complex conformational landscapes. Indeed, modern approaches to the heterogeneous reconstruction task can resolve 100s-1,000s of different maps from a single cryoEM dataset. How accurate these algorithms are, however, has proven difficult to rigorously assess, due to a lack of suitable benchmark datasets containing both realistic noise features and ground-truth labels. To address this obstacle, we recently developed a series of benchmark datasets that leverage the targeting power of Cas9 and the programmable heterogeneity of DNA to newly offer access to ground-truth per-particle structural labels in real data. Here, we challenged two popular heterogeneous reconstruction algorithms with mixed particle stacks resampled in silico from these datasets, finding that existing approaches resolve the encoded heterogeneity with limited accuracy. In particular, in realistic particle stacks with complex, multi-scale, and multi-axis heterogeneity, we observed that reconstruction of encoded heterogeneity depended strongly on the application of prior information about where heterogeneity was expected, and that individual particle assignments were made with significant error even when the correct structural states were reconstructed. Both molecular breathing motions and data collection features, such as defocus and projection angle, contributed to the observed particle assignment error. These results highlight important shortcomings of existing heterogeneous reconstruction methods and suggest new avenues for method development in both data collection strategies and in heterogeneous classification and reconstruction algorithms.
Open AccessHeterogeneous reconstruction algorithms for cryoEM achieve limited particle classification accuracy on real benchmark datasets
The emergence of single-particle cryoEM as a powerful method for structure determination has in large part been fueled by its ability to resolve both single static structures and complex conformational landscapes. Indeed, modern approaches to the heterogeneous reconstruction task can resolve 100s-1,000s of different maps from a single cryoEM dataset. How accurate these algorithms are, however, has proven difficult to rigorously assess, due to a lack of suitable benchmark datasets containing both realistic noise features and ground-truth labels. To address this obstacle, we recently developed a series of benchmark datasets that leverage the targeting power of Cas9 and the programmable heterogeneity of DNA to newly offer access to ground-truth per-particle structural labels in real data. Here, we challenged two popular heterogeneous reconstruction algorithms with mixed particle stacks resampled in silico from these datasets, finding that existing approaches resolve the encoded heterogeneity with limited accuracy. In particular, in realistic particle stacks with complex, multi-scale, and multi-axis heterogeneity, we observed that reconstruction of encoded heterogeneity depended strongly on the application of prior information about where heterogeneity was expected, and that individual particle assignments were made with significant error even when the correct structural states were reconstructed. Both molecular breathing motions and data collection features, such as defocus and projection angle, contributed to the observed particle assignment error. These results highlight important shortcomings of existing heterogeneous reconstruction methods and suggest new avenues for method development in both data collection strategies and in heterogeneous classification and reconstruction algorithms.
- Open Access
Engineered Cas9 complexes establish an experimentally grounded benchmark for heterogeneous cryoEM reconstruction methods
Single-particle cryoEM is increasingly used to resolve conformational and compositional ensembles, yet objective evaluation of heterogeneous reconstruction methods remains limited by the scarcity of experimental benchmarks with per-particle ground-truth labels. Indeed, many widely used experimental”benchmark” datasets necessarily validate observed states retrospectively while purely synthetic datasets provide ground-truth labels but typically fail to capture experimentally realistic complexities including confounding structural heterogeneity, imaging noise, contaminants, and orientation biases, which dominate real-world analyses. Here we develop an experimentally grounded benchmark dataset for heterogeneous reconstruction using catalytically inactive Streptococcus pyogenes Cas9 bound to a constant sgRNA and to target DNA duplexes engineered to carry extensions of defined length. We assembled, purified, vitrified, and imaged thirteen complexes independently, such that the dataset-of-origin provides an unambiguous label for each particle’s encoded state while preserving the full experimental complexity of cryoEM data. Independent refinements of the pure datasets recover the engineered DNA-extension signal and define a simple quantitative readout, DNA-extension occupancy, that increases monotonically with designed extension length. The same reconstructions also reveal substantial non-encoded conformational variability within the Cas9 core, showing that this benchmark embeds a known structural signal within broader structural heterogeneity that methods must confront in practice. To separate these axes of variation, we used systematic deep classification to generate curated particle subsets depleted of selected domain motions while retaining the encoded labels. We further provide pooled particle stacks with standardized per-particle poses in a common reference frame and a lightweight framework for in silico particle pooling to generate challenge datasets with user-defined ground-truth distributions of encoded and non-encoded structural heterogeneity. Together, this resource supports robust benchmarking of heterogeneous reconstruction algorithms and provides a biochemically tractable model system for evaluating entire cryoEM pipelines, including alternative data-collection and preprocessing approaches, under experimentally realistic conditions.
Open AccessEngineered Cas9 complexes establish an experimentally grounded benchmark for heterogeneous cryoEM reconstruction methods
Single-particle cryoEM is increasingly used to resolve conformational and compositional ensembles, yet objective evaluation of heterogeneous reconstruction methods remains limited by the scarcity of experimental benchmarks with per-particle ground-truth labels. Indeed, many widely used experimental”benchmark” datasets necessarily validate observed states retrospectively while purely synthetic datasets provide ground-truth labels but typically fail to capture experimentally realistic complexities including confounding structural heterogeneity, imaging noise, contaminants, and orientation biases, which dominate real-world analyses. Here we develop an experimentally grounded benchmark dataset for heterogeneous reconstruction using catalytically inactive Streptococcus pyogenes Cas9 bound to a constant sgRNA and to target DNA duplexes engineered to carry extensions of defined length. We assembled, purified, vitrified, and imaged thirteen complexes independently, such that the dataset-of-origin provides an unambiguous label for each particle’s encoded state while preserving the full experimental complexity of cryoEM data. Independent refinements of the pure datasets recover the engineered DNA-extension signal and define a simple quantitative readout, DNA-extension occupancy, that increases monotonically with designed extension length. The same reconstructions also reveal substantial non-encoded conformational variability within the Cas9 core, showing that this benchmark embeds a known structural signal within broader structural heterogeneity that methods must confront in practice. To separate these axes of variation, we used systematic deep classification to generate curated particle subsets depleted of selected domain motions while retaining the encoded labels. We further provide pooled particle stacks with standardized per-particle poses in a common reference frame and a lightweight framework for in silico particle pooling to generate challenge datasets with user-defined ground-truth distributions of encoded and non-encoded structural heterogeneity. Together, this resource supports robust benchmarking of heterogeneous reconstruction algorithms and provides a biochemically tractable model system for evaluating entire cryoEM pipelines, including alternative data-collection and preprocessing approaches, under experimentally realistic conditions.
- Open Access
- 11 March 2026
- Published by EMBL-EBI
Experimentally-grounded benchmark datasets for cryoEM heterogeneous reconstruction methods with engineered Cas9 complexes
- 11 March 2026
- Published by EMBL-EBI
Open AccessExperimentally-grounded benchmark datasets for cryoEM heterogeneous reconstruction methods with engineered Cas9 complexes
- Open Access
Application of monolayer graphene to cryo-electron microscopy grids for high-resolution structure determination
In cryogenic electron microscopy (cryo-EM), purified macromolecules are typically applied to a grid bearing a holey carbon foil, blotted to remove excess liquid and rapidly frozen in a roughly 20-100 nm thick layer of vitreous ice that is suspended across roughly 1 μm-wide foil holes. The resulting sample is then imaged using cryogenic transmission electron microscopy and, after substantial image processing, near-atomic resolution structures can be determined. Despite cryo-EM’s widespread adoption, sample preparation remains a severe bottleneck in cryo-EM workflows, with users often encountering challenges related to samples behaving poorly in the suspended vitreous ice. Recently, methods have been developed to modify cryo-EM grids with a single continuous layer of graphene, which acts as a support surface that often increases particle density in the imaged area and can reduce interactions between particles and the air-water interface. Here, we provide detailed protocols for the application of graphene to cryo-EM grids, and for rapidly assessing the relative hydrophilicity of the resulting grids. Additionally, we describe an EM-based method to confirm the presence of graphene by visualizing its characteristic diffraction pattern. Finally, we demonstrate the utility of these graphene supports by rapidly reconstructing a 2.7 Å resolution density map of an exemplar Cas9 complex using a highly pure sample at a relatively low concentration. SUMMARY: The application of support layers, such as graphene, to cryo-electron microscopy grids can increase the density of particles imaged, limit particle interactions with the air-water interface, reduce the extent of beam-induced motion, and, in some instances, improve the distribution of particle orientations. This paper describes a robust protocol for coating cryo-EM grids with a monolayer of graphene for improved cryo-sample preparation.
Open AccessApplication of monolayer graphene to cryo-electron microscopy grids for high-resolution structure determination
In cryogenic electron microscopy (cryo-EM), purified macromolecules are typically applied to a grid bearing a holey carbon foil, blotted to remove excess liquid and rapidly frozen in a roughly 20-100 nm thick layer of vitreous ice that is suspended across roughly 1 μm-wide foil holes. The resulting sample is then imaged using cryogenic transmission electron microscopy and, after substantial image processing, near-atomic resolution structures can be determined. Despite cryo-EM’s widespread adoption, sample preparation remains a severe bottleneck in cryo-EM workflows, with users often encountering challenges related to samples behaving poorly in the suspended vitreous ice. Recently, methods have been developed to modify cryo-EM grids with a single continuous layer of graphene, which acts as a support surface that often increases particle density in the imaged area and can reduce interactions between particles and the air-water interface. Here, we provide detailed protocols for the application of graphene to cryo-EM grids, and for rapidly assessing the relative hydrophilicity of the resulting grids. Additionally, we describe an EM-based method to confirm the presence of graphene by visualizing its characteristic diffraction pattern. Finally, we demonstrate the utility of these graphene supports by rapidly reconstructing a 2.7 Å resolution density map of an exemplar Cas9 complex using a highly pure sample at a relatively low concentration. SUMMARY: The application of support layers, such as graphene, to cryo-electron microscopy grids can increase the density of particles imaged, limit particle interactions with the air-water interface, reduce the extent of beam-induced motion, and, in some instances, improve the distribution of particle orientations. This paper describes a robust protocol for coating cryo-EM grids with a monolayer of graphene for improved cryo-sample preparation.