VDV. M. Doroshenko

V. M. Doroshenko

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


V. M. Doroshenko has a total of 24 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Analysis of experimental results of flow cytometric analysis of cell viability of the bacterial strain Escherichia coli under exposure to microwave radiation

    by V.B. Bayburin, V.M. Doroshenko, A.A. Nikiforov, Yu.V. Fadeeva, Z.R. Zenchenko, A.A. Shirokov, L.YU. Matora, V.A. Kirkitsa

    The mechanisms by which microwave radiation influences pathogenic microflora are currently not fully understood. To understand population dynamics and the response to microwave treatment, it is necessary to develop a method for assessing bacterial viability on contaminated metal instrument surfaces. This will allow for a step-by-step monitoring of cell population dynamics and the determination of optimal parameters for achieving complete decontamination. The aim of this experimental study is to analyze microorganism viability after each sterilization mode using flow cytometry, assess the ratio of live, dead, and damaged bacterial cell subpopulations of the Escherichia coli strain, and determine the optimal treatment parameters for complete instrument sterilization. This paper presents the experimental results of a flow cytometric analysis of the viability of bacterial suspensions after microwave sterilization of medical instruments contaminated with the Escherichia coli strain under various time regimens and at a single power level. The optimal parameters for complete instrument sterilization are determined. The study utilized the Escherichia coli K-12 (IBPPM 204) microbial strain provided by the Rhizospheric Microorganism Collection at the Institute of Biochemistry and Physiology of Microorganisms, Russian Academy of Sciences. The experimental results will be used in the final development of microwave sterilizers capable of effectively decontaminating pathogenic microflora during sterilization of medical instruments under a wide range of conditions.

  • Parameters optimization of the HEMT-transistor equivalent circuit

    by A.L. Khvalin, V.M. Doroshenko

    Most domestic and foreign transistors, as a rule, do not have computer models compatible with modern computer-aided design systems. This is largely explained by the complexity of solving the corresponding optimization problems of determining a set of parameters for an equivalent transistor model. The relevance of the work carried out is associated with the lack of modern element base in the libraries of well-known computer CAD systems, which significantly limits the possibilities of designing specific devices. The article presents the main stages of modeling the low-noise HEMT-transistor FPD6836P70. The basic model of the transistor has more than 60 parameters, the optimization goals are eight experimentally frequency (amplitude and phase of S-parameters in an ultra-wide operating range) characteristics of the FPD6836P70 transistor. Thus, the problem of determining the values of the parameters of the basic transistor model belongs to a complex class of so-called multicriteria multiparameter optimization problems. Since existing computer methods for searching for optimal solutions do not have a universal algorithm suitable for solving any optimization problem, solving specific optimization problems requires the development of an individual approach. The goal of the simulation was to obtain calculated characteristics that were as close as possible to the measured frequency characteristics of the transistor. The article describes a methodology for modeling frequency characteristics based on the common basic model of the EEHEMT-transistor. The article defines a set of parameters of the transistor equivalent circuit that affect the frequency characteristics. The optimal numerical values of the parameters of the equivalent circuit EEHEMT are found, and the results of calculations of a family of frequency characteristics of the transistor are presented. The corresponding problems of parametric optimization are formulated and solved. Experimental frequency characteristics of the HEMT were used as optimization goals. The technical novelty of the solution to the problem presented in the article lies in the division of the general problem into two subtasks: optimization of static and frequency characteristics. This approach makes it possible to reduce the complexity of individual subtasks, since the number of parameters and optimization goals is reduced. The analysis of the obtained results shows that the calculated frequency characteristics differ from the measured ones by no more than 21%. The article describes a methodology for modeling the frequency characteristics of the FPD6836P70 transistor based on the common basic model EEHEMT. A set of parameters of the transistor equivalent circuit that affect the frequency characteristics is determined. The optimal numerical values of the parameters of the EEHEMT equivalent circuit are found, and the results of calculations of the family of frequency characteristics of the FPD6836P70 transistor are presented.

  • Impact of primary power source parameters on the operating mode of the microwave sterilizer

    by V.B. Baiburin, I.I. Artyukhov, V.M. Doroshenko, Nikolaev, A.A. Nikiforov

    The operation of a microwave sterilizer is disturbed by various factors. These are primarily deviations in the quality indicators of the electric power generated by the primary power source. To design a built-in power source, information is needed on the degree of influence of disturbing effects on the processes in the electromagnetic sterilizer. By modeling circuits in the MATLAB environment with the Simulink extension package, data were obtained on the influence of the quality indicators of the electric power of the primary power source on the operating mode of the microwave sterilizer. The results obtained can be used in the development of microwave sterilizers capable of effectively performing microwave decontamination of pathogenic microflora during sterilization of medical instruments in a wide range of conditions.

  • Electrodynamic modeling of the operating chamber of a microwave sterilizer with slot excitation element

    by V.V. Komarov, V.B. Baiburin, V.M. Doroshenko, I.I. Artyukhov, A.A. Nikiforov

    Sterilization of surgery instruments in an important preliminary stage of any medical operation. Microwave energy can be successfully used for these purposes. The distribution of electromagnetic fields of different modes in the rectangular cavity chamber of a microwave sterilizer mainly depends on the excitation element of the resonator. At the same time, the influence of the shape and location of this element in the design of the sterilizer remains poorly understood. Analysis of electromagnetic fields near the surface of metal objects irradiated with microwave energy for various options for placing a slot excitation element on the walls of the operating chamber was the goal of this work. Using a 3-D numerical model based on the finite element method, the tangential component of the electric field above the surface of a metal plate irradiated with a microwave energy in the operating chamber of a microwave sterilizer was investigated. In this case, the plate is placed in a plastic container with an immersion medium (water), the electrophysical properties of which depend on the temperature. The factors that have the greatest influence on the magnitude of the field strength in the interaction region have been established. The obtained numerical data can be used to reduce the metal consumption of the waveguide excitation element of the operating chamber of the sterilizer, which is currently used, and at the same time to increase the efficiency of microwave decontamination of pathological microflora during sterilization of medical instruments.

  • Emergency decontamination of pathogenic microflora using electromagnetic radiation

    by V.M. Doroshenko, V.A. Kirkitsa

    An important problem of health care has always been ensuring safety during surgical and other manipulations. Currently, many methods are known for disinfecting medical objects based on treatment with steam, hot air, ultraviolet, X-ray and electromagnetic radiation. The listed methods have both their obvious advantages and unavoidable disadvantages, which are described in detail in the work [1-12]. A promising method is the sterilization of medical instruments using a microwave field. Patents for similar development methods [13,14] were registered in the 90s of the last century, however, in the shown processing technologies it was not possible to avoid sparking, which excluded the processing of metal instruments. In turn, traditional methods used in hospitals, due to the effect of high temperatures, do not allow the processing of plastic instruments. This problem was solved with the help of the developed microwave sterilizer, which carries out decontamination due to the effect of an electromagnetic field on microflora, and not due to the effect of high temperatures.

  • Development of broadband high-precision microwave analyzer based on multi-probe measuring line

    by V.P. Meschanov, A.A. L’vOv, B.M. Kats, P.A. L’vOv, K.A. Sayapin, V.M. Doroshenko

    Objectives. The actual technical implementation problem of broadband reflectometers based on multi-probe transmission lines (MTL) is investigated. Methods. The analysis of optimal methods for processing output digital signals from quadric detectors of MTL probes is performed. Methods for increasing the accuracy of measurements using this reflectometer in narrow and wide frequency ranges based on the optimal choice of a limited number of probes arrangement along the line path are proposed. Main results. Reflectometer designs with a limited number of probes (no more than 8) are obtained, allowing measurements with potentially achievable accuracy in a frequency range of up to 6 octaves. The created experimental samples of narrowband and wideband automatic network analyzers based on MTL are described and their accuracy characteristics are demonstrated, which confirmed the theoretical conclusions. Conclusion. Conclusions that show areas of application of the developed broadband high-precision microwave analyzer based on multi-probe measuring line was formulated.

  • Open Access

    Smale-Williams Solenoids in a System of Coupled Bonhoeffer-van der Pol Oscillators

    by V. M. Doroshenko, V. P. Kruglov, S. P. Kuznetsov

    The principle of constructing a new class of systems with hyperbolic chaotic attractors is proposed. It is based on using oscillators, the transfer of excitation between which is provided resonantly due to the difference in the frequencies of small and large oscillations by an integer number of times being accompanied by phase transformation according to Bernoulli nap. We consider a system with Smale-Williams attractor, which is based on two coupled Bonhoeffer-van der Pol oscillators. The oscillators manifest activity and suppression turn by turn. With appropriate selection of the modulation, relaxation oscillations occur at the end of each activity stage, the frequency of which is by an integer factor $M = 2,3,4,\ldots$ smaller than that of small oscillations. When the partner oscillator enters the activity stage, the oscillations start being stimulated by the M-th harmonic of the relaxation oscillations, so that the transformation of phase during the modulation period corresponds to the M-fold Bernoulli map. In the state space of the Poincar\'e map this corresponds to Smale-Williams attractor, constructed with M-fold increase in the number of turns of the winding at each step of the mapping. The results of numerical studies confirming the occurrence of the hyperbolic attractors in certain parameter domains are presented, including the portraits of attractors, diagrams illustrating the phase transformation according to the Bernoulli map, Lyapunov exponents, and charts of regimes in parameter planes. The hyperbolic nature of the attractors is verified by numerical tests that confirm absence of tangencies of stable and unstable manifolds for trajectories on the attractor (criterion of angles). An electronic circuit is proposed that implements this principle of obtaining the hyperbolic chaos and its functioning is demonstrated using the software package Multisim.

  • Open Access

    Smale – Williams Solenoids in a System of Coupled Bonhoeffer – van der Pol Oscillators

    by V.M. Doroshenko, Saratov State Medical University, V.P. Kruglov, S.P. Kuznetsov, Saratov Branch of Kotel’nikov’s Institute of Radio-Engineering and Electronics of RAS

    Smale – Williams Solenoids in a System of Coupled Bonhoeffer – van der Pol Oscillators, Doroshenko V. M., Kruglov V. P., Kuznetsov S. P.

  • Open Access

    Chaos generator with the Smale–Williams attractor based on oscillation death

    by В.м. Дорошенко, Саратовский Государственный Университет, В.п. Круглов, С.п. Кузнецов, Саратовский Государственный Университет Им. Н. Г. Чернышевского, Саратовский Филиал Институт Радиотехники И Электроники Ран Им. В. А. Котельникова

    Chaos generator with the Smale–Williams attractor based on oscillation death, Doroshenko V. M., Kruglov V. P., Kuznetsov S. P.